Sensitivity and Specificity of Serum and Synovial Fluid Markers in Diagnosis of Infection in Head-Neck Taper Corrosion of Metal-On-Polyethylene Total Hip Arthroplasty

被引:8
|
作者
Kwon, Young-Min [1 ]
Mahajan, John [1 ]
Tirumala, Venkatsaiakhil [1 ]
Oganesyan, Ruben [1 ]
Yeo, Ingwon [1 ]
Klemt, Christian [1 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Dept Orthopaed Surg, Bioengn Lab, 55 Fruit St,Yawkey Suite 3B, Boston, MA 02114 USA
来源
JOURNAL OF ARTHROPLASTY | 2020年 / 35卷 / 12期
关键词
adverse local tissue reaction; periprosthetic joint infection; head-neck taper corrosion; cobalt and chromium metal ion level; metal-on-polyethylene total hip; arthroplasty; LOCAL TISSUE-REACTIONS; JUNCTION; OUTCOMES; UTILITY; STEM;
D O I
10.1016/j.arth.2020.06.058
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The accurate diagnosis of periprosthetic joint infection (PJI) in the setting of adverse local tissue reactions in patients with metal-on-polyethylene (MoP) total hip arthroplasty (THA) secondary to head-neck taper junction corrosion is challenging as it frequently has the appearance of purulence. The aim of this study is to evaluate the utility of erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), and synovial fluid markers in diagnosing PJI in failed MoP THA due to head-neck taper corrosion. Methods: A total of 89 consecutive patients with MoP THA with head-neck taper corrosion in 2 groups was evaluated: (1) infection group (n = 11) and (2) noninfection group (n = 78). All patients had highly crossed polyethylene with cobalt chromium femoral heads and had preoperative synovial fluid aspiration. In addition, serum cobalt and chromium levels were analyzed. Results: The optimal cutoff value for synovial white blood cell was 2144 with 93% sensitivity and 84% specificity. Neutrophil count optimal cutoff value was 82% with 93% sensitivity and 82% specificity. Receiver operating characteristic analysis of ESR and CRP determined optimal cutoff at 57 mm/h and 35 mg/L with 57% sensitivity and 94% specificity and 93% sensitivity and 76% specificity, respectively. There were no significant differences in metal ion levels between the infected and noninfected groups. Conclusion: The results of this study suggest that ESR and CRP are useful in excluding PJI, whereas both synovial white blood cell count and neutrophil percentage in hip aspirate are useful markers for diagnosing infection in MoP THA patients with head-neck taper corrosion associated adverse local tissue reaction. (C) 2020 Elsevier Inc. All rights reserved.
引用
下载
收藏
页码:3737 / 3742
页数:6
相关论文
共 49 条
  • [31] Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial
    Wierd P Zijlstra
    Nanne Bos
    Jos JAM van Raaij
    BMC Musculoskeletal Disorders, 9
  • [32] Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial
    Zijlstra, Wierd P.
    Bos, Nanne
    van Raaij, Jos J. A. M.
    BMC MUSCULOSKELETAL DISORDERS, 2008, 9 (1)
  • [33] Metal serum levels in 48 patients bearing a chromium-cobalt total hip arthroplasty with a metal-on-polyethylene combination
    Damie, F
    Favard, L
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2004, 90 (03): : 241 - 248
  • [34] Trunnion Corrosion in Metal-on-Polyethylene Total Hip Arthroplasty: A Case Series: Erratum (vol 25, pg 133, 2017)
    Raju, Sivashanmugam
    Chinnakkannu, Karthikeyan
    Puttaswamy, Mohan K.
    Phillips, Matthew J.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2017, 25 (03) : 250 - 250
  • [35] Clinical Outcomes and Risk Factors for Re-Revision Due to Trunnion Corrosion in Primary Metal-on-Polyethylene Total Hip Arthroplasty
    Ali, Erden
    Neufeld, Michael E.
    Howard, Lisa C.
    Masri, Bassam A.
    Greidanus, Nelson, V
    Garbuz, Donald S.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (09): : S404 - S409
  • [36] High Early Major Complication Rate After Revision for Mechanically Assisted Crevice Corrosion in Metal-on-Polyethylene Total Hip Arthroplasty
    McGrory, Brian J.
    Jorgensen, Anna H.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (12): : 3704 - 3710
  • [37] Elevated Intra-Articular Cobalt and Chromium Levels in Mechanically Assisted Crevice Corrosion in Metal-on-Polyethylene Total Hip Arthroplasty
    McGrory, Brian J.
    Payson, Abigail M.
    MacKenzie, Johanna A.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (05): : 1654 - 1658
  • [38] Diagnosis and Management of Adverse Local Tissue Reactions Secondary to Corrosion at the Head-Neck Junction in Patients With Metal on Polyethylene Bearings
    Plummer, Darren R.
    Berger, Richard A.
    Paprosky, Wayne G.
    Sporer, Scott M.
    Jacobs, Joshua J.
    Della Valle, Craig J.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (01): : 264 - 268
  • [39] Femoral head wear and metallosis caused by damaged titanium porous coating after primary metal-on-polyethylene total hip arthroplasty: a case report
    Delimar, Domagoj
    Bohacek, Ivan
    Dimnjakovic, Damjan
    Viderscak, Dalibor
    Schauperl, Zdravko
    CROATIAN MEDICAL JOURNAL, 2018, 59 (05) : 253 - 257
  • [40] Adverse Local Tissue Reaction due to Mechanically Assisted Crevice Corrosion Presenting as Late Instability Following Metal-on-Polyethylene Total Hip Arthroplasty
    Hannon, Charles P.
    Cotter, Eric J.
    Cooper, H. John
    Deirmengian, Carl A.
    Rodriguez, Jose A.
    Urban, Robert M.
    Paprosky, Wayne G.
    Jacobs, Joshua J.
    JOURNAL OF ARTHROPLASTY, 2020, 35 (09): : 2666 - 2670