Pulmonary embolism: Radiation dose with multi-detector row CT and digital angiography for diagnosis

被引:24
|
作者
Coche, Emmanuel
Vynckier, Stefaan
Octave-Prignot, Michelle
机构
[1] Univ Catholique Louvain, Clin Univ St Luc, Dept Med Imaging, B-1200 Brussels, Belgium
[2] Univ Catholique Louvain, Clin Univ St Luc, Dept Radiat Therapy, B-1200 Brussels, Belgium
关键词
D O I
10.1148/radiol.2402050580
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare radiation dose delivered at four- and 16- detector row computed tomography ( CT) with a dose-modulation program and that delivered at digital angiography for evaluation of pulmonary embolism ( PE). Materials and Methods: The part of the study involving patients ( seven women, four men; mean age, 62 years +/- 16 [ standard deviation]; range, 41 - 85 years) was approved by the institutional review board. Patients gave written informed consent. Exposure was performed with an anthropomorphic phantom with thermoluminescent dosimeters for four - detector row CT without the dose-modulation program and 16- detector row CT without and with the dose-modulation program with standard protocols for pulmonary CT angiography ( 120 kV, 144 mAs, four and 16- detector rows with 1.00- and 0.75-mm section thickness, respectively). Digital angiograms were acquired with four standard projections at 80 kV. For digital angiography, radiation dose was calculated according to phantom measurements and adapted to acquisition and fluoroscopy times. Distribution of dose was compared for CT and digital angiography. Results: During pulmonary CT angiography, mean radiation dose delivered at middle of chest was 21.5, 19.5, and 18.2 mGy for four - detector row CT and for 16- detector row CT without and with dose-modulation program, respectively. At the same level, a mean dose of 91 mGy was delivered with digital angiography. The dose adjusted to clinical conditions was 139.0 mGy for digital angiography and could be reduced after technical adjustment. Ratios of maximum dose to mean dose were 1.15 and 2.96 for CT and digital angiography, respectively. With application of the dose-modulation program at 16- detector row CT, radiation dose was reduced 15%-20% at the upper chest. Conclusion: Multi - detector row CT delivers a lower radiation dose, with better spatial distribution of dose, than does pulmonary CT angiography. With 16- detector row CT and a dose-modulation program, radiation dose is decreased during PE work-up.
引用
收藏
页码:690 / 697
页数:8
相关论文
共 50 条
  • [21] Treatment decision in ruptured intracranial aneurysms: comparison between multi-detector row CT angiography and digital subtraction angiography
    Taschner, C.-A.
    Thines, L.
    Lernout, M.
    Lejeune, J.-P.
    Lederc, X.
    [J]. JOURNAL OF NEURORADIOLOGY, 2007, 34 (04) : 243 - 249
  • [22] CT Dose Optimization When Changing to CT Multi-Detector Row Technology
    Verdun, Francis R.
    Gutierrez, Daniel
    Schnyder, Pierre
    Aroua, Abbas
    Bochud, Francois
    Gudinchet, Francois
    [J]. CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2007, 36 (04) : 176 - 184
  • [23] Imaging of acute pulmonary embolism using multi-detector CT angiography: An update on imaging technique and interpretation
    Hartmann, Ieneke J. C.
    Wittenberg, Rianne
    Schaefer-Prokop, Cornelia
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2010, 74 (01) : 40 - 49
  • [24] Detection of submucosal gastric fundal varices with multi-detector row CT angiography
    Willmann, JK
    Weishaupt, D
    Böhm, T
    Pfammatter, T
    Seifert, B
    Marincek, B
    Bauerfeind, P
    [J]. GUT, 2003, 52 (06) : 886 - 892
  • [25] Techniques for the detection of coronary atherosclerosis: Multi-detector row CT coronary angiography
    Vogl, TJ
    Abolmaali, ND
    Diebold, T
    Engelmann, K
    Ay, M
    Dogan, S
    Wimmer-Greinecker, G
    Moritz, A
    Herzog, C
    [J]. RADIOLOGY, 2002, 223 (01) : 212 - 220
  • [26] Role of multi-detector row CT angiography in the management of gastric fundal varices
    Matsumoto, A
    Sugano, Y
    Yasuda, M
    Takimoto, K
    [J]. GUT, 2004, 53 (03) : 467 - 467
  • [27] Anomalous coronary arteries in adults: Depiction at multi-detector row CT angiography
    Datta, J
    White, CS
    Gilkeson, RC
    Meyer, CA
    Kansal, S
    Jani, ML
    Arildsen, RC
    Read, K
    [J]. RADIOLOGY, 2005, 235 (03) : 812 - 818
  • [28] Detection of intracranial aneurysms: Multi-detector row CT angiography compared with DSA
    Jayaraman, MV
    Mayo-Smith, WW
    Tung, GA
    Haas, RA
    Rogg, JM
    Mehta, NR
    Doberstein, CE
    [J]. RADIOLOGY, 2004, 230 (02) : 510 - 518
  • [29] Multi-detector row CT angiography in the assessment of carotid artery disease in symptomatic patients:: Comparison with rotational angiography and digital subtraction angiography
    Berg, M
    Zhang, Z
    Ikonen, A
    Sipola, P
    Kälviäinen, R
    Manninen, H
    Vanninen, R
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (05) : 1022 - 1034
  • [30] Bronchial and nonbronchial systemic arteries at multi-detector row CT angiography: Comparison with conventional angiography
    Remy-Jardin, M
    Bouaziz, N
    Dumont, P
    Brillet, PY
    Bruzzi, J
    Remy, J
    [J]. RADIOLOGY, 2004, 233 (03) : 741 - 749