Detection of intracranial aneurysms: Multi-detector row CT angiography compared with DSA

被引:143
|
作者
Jayaraman, MV
Mayo-Smith, WW
Tung, GA
Haas, RA
Rogg, JM
Mehta, NR
Doberstein, CE
机构
[1] Rhode Isl Hosp, Brown Med Sch, Dept Diagnost Imaging, Providence, RI USA
[2] Rhode Isl Hosp, Brown Med Sch, Dept Neurosurg, Providence, RI USA
关键词
Aneurysm; intracranial; computed tomography; angiography; digital subtraction angiography; comparative studies; hemorrhage;
D O I
10.1148/radiol.2302021465
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To prospectively compare the effectiveness of multi-detector row computed tomographic (CT) angiography with that of conventional intraarterial digital subtraction angiography (DSA) used to detect intracranial aneurysms in patients with nontraumatic acute subarachnoid hemorrhage. MATERIALS AND METHODS: Thirty-five consecutive adult patients with acute subarachnoid hemorrhage were recruited into the institutional review board-approved study and gave informed consent. All patients underwent both multi-detector row CT angiography and DSA no more than 12 hours apart. CT angiography was performed with a multi-detector row scanner (four detector rows) by using collimation of 1.25 mm and pitch of 3. Images were interpreted at computer workstations in a blinded fashion. Two radiologists independently reviewed the CT images, and two other radiologists independently reviewed the DSA images. The presence and location of aneurysms were rated on a five-point scale for certainty. Sensitivity and specificity were calculated independently for image interpretation performed by the two CT image readers and the second DSA image reader by using interpretation as the reference standard. the first DSA reader RESULTS: A total of 26 aneurysms were detected at DSA in 21 patients, and no aneurysms were detected in 14 patients. Sensitivity and specificity for CT angiography were, respectively, 90% and 93% for reader 1 and 81 % and 93% for reader 2. The mean diameter of aneurysms detected on CT angiographic images was 4.4 mm, and the smallest aneurysm detected was 2.2 mm in diameter. Aneurysms that were missed at initial interpretation of CT angiographic images were identified at retrospective reading. CONCLUSION: Multi-detector row CT angiography has high sensitivity and specificity for detection of intracranial aneurysms, including small aneurysms, in patients with nontraumatic acute subarachnoid hemorrhage.
引用
收藏
页码:510 / 518
页数:9
相关论文
共 50 条
  • [1] Value of CT angiography compared with DSA in the detection of intracranial aneurysms.
    Dillo, W
    Brassel, F
    Becker, H
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1996, 165 (03): : 227 - 231
  • [2] Treatment decision in ruptured intracranial aneurysms: comparison between multi-detector row CT angiography and digital subtraction angiography
    Taschner, C.-A.
    Thines, L.
    Lernout, M.
    Lejeune, J.-P.
    Lederc, X.
    [J]. JOURNAL OF NEURORADIOLOGY, 2007, 34 (04) : 243 - 249
  • [3] Detection of submucosal gastric fundal varices with multi-detector row CT angiography
    Willmann, JK
    Weishaupt, D
    Böhm, T
    Pfammatter, T
    Seifert, B
    Marincek, B
    Bauerfeind, P
    [J]. GUT, 2003, 52 (06) : 886 - 892
  • [4] Techniques for the detection of coronary atherosclerosis: Multi-detector row CT coronary angiography
    Vogl, TJ
    Abolmaali, ND
    Diebold, T
    Engelmann, K
    Ay, M
    Dogan, S
    Wimmer-Greinecker, G
    Moritz, A
    Herzog, C
    [J]. RADIOLOGY, 2002, 223 (01) : 212 - 220
  • [5] DSA versus multi-detector row CT angiography in peripheral arterial disease: Randomized controlled trial
    Kock, MCJM
    Adriaensen, MEAPM
    Pattynama, PMT
    van Sambeek, MRHM
    van Urk, H
    Stijnen, T
    Hunink, MGM
    [J]. RADIOLOGY, 2005, 237 (02) : 727 - 737
  • [6] Multi-Detector Row CT Angiography of the Neck in Blunt Trauma
    Munera, Felipe
    Foley, Mark
    Chokshi, Falgun H.
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2012, 50 (01) : 59 - +
  • [7] Multi-detector row CT angiography in patients with abdominal angina
    Cademartiri, F
    Raaijmakers, RHJM
    Kuiper, JW
    van Dijk, LC
    Pattynama, PMT
    Krestin, GP
    [J]. RADIOGRAPHICS, 2004, 24 (04) : 969 - 984
  • [8] Does multi-detector row CT pulmonary angiography reduce the incremental value of indirect CT venography compared with single-detector row CT pulmonary angiography?
    Ghaye, Benoit
    Nchimi, Alain
    Noukoua, Charlemagne T.
    Dondelinger, Robert F.
    [J]. RADIOLOGY, 2006, 240 (01) : 256 - 262
  • [9] Diagnosis of venous thromboembolism by single-detector row and multi-detector row CT angiography
    Koyuncu, Abdullah
    Bozlar, Ugur
    Ustunsoz, Bahri
    Ors, Fatih
    Tasar, Mustafa
    Deniz, Omer
    Balkan, Arzu
    Somuncu, Ibrahim
    [J]. TUBERKULOZ VE TORAK-TUBERCULOSIS AND THORAX, 2007, 55 (01): : 24 - 33
  • [10] Multi-detector row spiral CT pulmonary angiography: Comparison with single-detector row spiral CT
    Raptopoulos, V
    Boiselle, PM
    [J]. RADIOLOGY, 2001, 221 (03) : 606 - 613