Detection of intracranial aneurysms: Multi-detector row CT angiography compared with DSA

被引:143
|
作者
Jayaraman, MV
Mayo-Smith, WW
Tung, GA
Haas, RA
Rogg, JM
Mehta, NR
Doberstein, CE
机构
[1] Rhode Isl Hosp, Brown Med Sch, Dept Diagnost Imaging, Providence, RI USA
[2] Rhode Isl Hosp, Brown Med Sch, Dept Neurosurg, Providence, RI USA
关键词
Aneurysm; intracranial; computed tomography; angiography; digital subtraction angiography; comparative studies; hemorrhage;
D O I
10.1148/radiol.2302021465
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To prospectively compare the effectiveness of multi-detector row computed tomographic (CT) angiography with that of conventional intraarterial digital subtraction angiography (DSA) used to detect intracranial aneurysms in patients with nontraumatic acute subarachnoid hemorrhage. MATERIALS AND METHODS: Thirty-five consecutive adult patients with acute subarachnoid hemorrhage were recruited into the institutional review board-approved study and gave informed consent. All patients underwent both multi-detector row CT angiography and DSA no more than 12 hours apart. CT angiography was performed with a multi-detector row scanner (four detector rows) by using collimation of 1.25 mm and pitch of 3. Images were interpreted at computer workstations in a blinded fashion. Two radiologists independently reviewed the CT images, and two other radiologists independently reviewed the DSA images. The presence and location of aneurysms were rated on a five-point scale for certainty. Sensitivity and specificity were calculated independently for image interpretation performed by the two CT image readers and the second DSA image reader by using interpretation as the reference standard. the first DSA reader RESULTS: A total of 26 aneurysms were detected at DSA in 21 patients, and no aneurysms were detected in 14 patients. Sensitivity and specificity for CT angiography were, respectively, 90% and 93% for reader 1 and 81 % and 93% for reader 2. The mean diameter of aneurysms detected on CT angiographic images was 4.4 mm, and the smallest aneurysm detected was 2.2 mm in diameter. Aneurysms that were missed at initial interpretation of CT angiographic images were identified at retrospective reading. CONCLUSION: Multi-detector row CT angiography has high sensitivity and specificity for detection of intracranial aneurysms, including small aneurysms, in patients with nontraumatic acute subarachnoid hemorrhage.
引用
收藏
页码:510 / 518
页数:9
相关论文
共 50 条
  • [31] Pancreas divisum: Depiction with multi-detector row CT
    Soto, JA
    Lucey, BC
    Stuhlfaut, JW
    [J]. RADIOLOGY, 2005, 235 (02) : 503 - 508
  • [32] Multi-detector row CT artifacts that mimic disease
    Cody, DD
    Stevens, DM
    Ginsberg, LE
    [J]. RADIOLOGY, 2005, 236 (03) : 756 - 761
  • [33] Comparison of 16-row multislice CT angiography with conventional angiography for detection and evaluation of intracranial aneurysms
    Donmez, Halil
    Serifov, Elman
    Kahriman, Guven
    Mavili, Ertugrul
    Durak, Ahmet Candan
    Menku, Ahmet
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (02) : 455 - 461
  • [34] Colonic distention in multi-detector row CT colonography
    Bruzzi, JF
    Fenlon, HM
    [J]. RADIOLOGY, 2004, 231 (01) : 282 - 282
  • [35] Multi-detector row CT: Radiation dose characteristics
    Hamberg, LM
    Rhea, JT
    Hunter, GJ
    Thrall, JH
    [J]. RADIOLOGY, 2003, 226 (03) : 762 - 772
  • [36] Short pancreas: evaluation with multi-detector row CT
    Murat Acar
    Bumin Degirmenci
    Servet Tatli
    [J]. Surgical and Radiologic Anatomy, 2010, 32 : 853 - 858
  • [37] Detection and evaluation of intracranial aneurysms with 16-row multislice CT angiography: Comparison with conventional angiography
    Uysal E.
    Oztora F.
    Ozel A.
    Erturk S.M.
    Yıldırım H.
    Basak M.
    [J]. Emergency Radiology, 2008, 15 (5) : 311 - 316
  • [38] Short pancreas: evaluation with multi-detector row CT
    Acar, Murat
    Degirmenci, Bumin
    Tatli, Servet
    [J]. SURGICAL AND RADIOLOGIC ANATOMY, 2010, 32 (09) : 853 - 858
  • [39] Carotid artery wall thickness: comparison between sonography and multi-detector row CT angiography
    Saba, Luca
    Sanfilippo, Roberto
    Montisci, Roberto
    Mallarini, Giorgio
    [J]. NEURORADIOLOGY, 2010, 52 (02) : 75 - 82
  • [40] Carotid artery wall thickness: comparison between sonography and multi-detector row CT angiography
    Luca Saba
    Roberto Sanfilippo
    Roberto Montisci
    Giorgio Mallarini
    [J]. Neuroradiology, 2010, 52 : 75 - 82