Carotid artery wall thickness: comparison between sonography and multi-detector row CT angiography

被引:43
|
作者
Saba, Luca [1 ]
Sanfilippo, Roberto [3 ]
Montisci, Roberto [3 ]
Mallarini, Giorgio [1 ,2 ]
机构
[1] Univ Cagliari, Dept Radiol, Policlin Univ, I-09045 Cagliari, Italy
[2] Osped San Giovanni Dio, Inst Radiol, I-09126 Cagliari, Italy
[3] Policlin Univ, Dept Vasc Surg, I-09045 Cagliari, Italy
关键词
Carotid artery; Stroke; MDCTA; CAWT; IMT; INTIMA-MEDIA THICKNESS; CARDIOVASCULAR RISK-FACTORS; ULTRASOUND MEASUREMENT; FAMILIAL HYPERCHOLESTEROLEMIA; ATHEROSCLEROTIC PLAQUES; PROGRESSION; ULTRASONOGRAPHY; REPRODUCIBILITY; POPULATION; MORPHOLOGY;
D O I
10.1007/s00234-009-0589-5
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Prospective studies have shown that an increased thickness of the carotid wall is a significant predictor of coronary and cerebrovascular complications. Our purpose was to assess the agreement between multi-detector row computed tomography (CT) angiography (MDCTA) and colour Doppler ultrasound (CD-US) in measuring carotid artery wall thickness (CAWT) and the intima-media thickness (IMT). Altogether, 97 subjects (age range 64-84 years) were prospectively analysed using a four-detector row CT and a sonographic scanner. In total, 46 subjects had shown cerebral ischaemic symptoms. CAWT and IMT were measured in each patient using MDCTA and CD-US (by applying a digital calliper), respectively. Continuous data were described as the mean value +/- standard deviation and were compared using the Mann-Whitney U test. A p value < 0.05 was considered significant. Bland-Altman statistics was employed to measure the agreement between MDCTA and CD-US. CAWT ranged from 0.5 to 1.53 mm, with a mean value of 0.9072 mm. IMT ranged from 0.46 to 1.5 mm, with a mean value of 0.8839 mm. By analysing the Bland-Altman plot, we observed an excellent agreement between CD-US and MDCTA with a bias between methods of 0.023 +/- 0.0424 mm. A limit of agreement from -0.06 to 0.106 was recorded. Correlation coefficient r was 0.9855 (95% confidence interval 0.9808-0.989). Mann-Whitney U test indicated a p value of 0.377. Obtained results indicated a significant agreement between MDCTA and CD-US in the measurement of CAWT and IMT.
引用
收藏
页码:75 / 82
页数:8
相关论文
共 50 条
  • [1] Carotid artery wall thickness: comparison between sonography and multi-detector row CT angiography
    Luca Saba
    Roberto Sanfilippo
    Roberto Montisci
    Giorgio Mallarini
    [J]. Neuroradiology, 2010, 52 : 75 - 82
  • [2] Carotid artery wall thickness and ischemic symptoms: evaluation using multi-detector-row CT angiography
    Saba, Luca
    Sanfilippo, Roberto
    Pascalis, Luigi
    Montisci, Roberto
    Caddeo, Giancarlo
    Mallarini, Giorgio
    [J]. EUROPEAN RADIOLOGY, 2008, 18 (09) : 1962 - 1971
  • [3] Carotid artery wall thickness and ischemic symptoms: evaluation using multi-detector-row CT angiography
    Luca Saba
    Roberto Sanfilippo
    Luigi Pascalis
    Roberto Montisci
    Giancarlo Caddeo
    Giorgio Mallarini
    [J]. European Radiology, 2008, 18 : 1962 - 1971
  • [4] Multi-detector row CT angiography in the assessment of carotid artery disease in symptomatic patients:: Comparison with rotational angiography and digital subtraction angiography
    Berg, M
    Zhang, Z
    Ikonen, A
    Sipola, P
    Kälviäinen, R
    Manninen, H
    Vanninen, R
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (05) : 1022 - 1034
  • [5] Multi-detector row spiral CT pulmonary angiography: Comparison with single-detector row spiral CT
    Raptopoulos, V
    Boiselle, PM
    [J]. RADIOLOGY, 2001, 221 (03) : 606 - 613
  • [6] Comparison between Carotid Artery Wall Thickness Measured by Multidetector Row Computed Tomography Angiography and Intimae-Media Thickness Measured by Sonography
    Savic, Zivorad N.
    Soldatovic, Ivan I.
    Brajovic, Milan D.
    Pavlovic, Aleksandra M.
    Mladenovic, Dusan R.
    Skodric-Trifunovic, Vesna D.
    [J]. THESCIENTIFICWORLDJOURNAL, 2011, 11 : 1582 - 1590
  • [7] Bronchial and nonbronchial systemic arteries at multi-detector row CT angiography: Comparison with conventional angiography
    Remy-Jardin, M
    Bouaziz, N
    Dumont, P
    Brillet, PY
    Bruzzi, J
    Remy, J
    [J]. RADIOLOGY, 2004, 233 (03) : 741 - 749
  • [8] Multi-Detector Row CT Angiography of the Neck in Blunt Trauma
    Munera, Felipe
    Foley, Mark
    Chokshi, Falgun H.
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2012, 50 (01) : 59 - +
  • [9] Multi-detector row CT angiography in patients with abdominal angina
    Cademartiri, F
    Raaijmakers, RHJM
    Kuiper, JW
    van Dijk, LC
    Pattynama, PMT
    Krestin, GP
    [J]. RADIOGRAPHICS, 2004, 24 (04) : 969 - 984
  • [10] Treatment decision in ruptured intracranial aneurysms: comparison between multi-detector row CT angiography and digital subtraction angiography
    Taschner, C.-A.
    Thines, L.
    Lernout, M.
    Lejeune, J.-P.
    Lederc, X.
    [J]. JOURNAL OF NEURORADIOLOGY, 2007, 34 (04) : 243 - 249