Carotid artery wall thickness: comparison between sonography and multi-detector row CT angiography

被引:43
|
作者
Saba, Luca [1 ]
Sanfilippo, Roberto [3 ]
Montisci, Roberto [3 ]
Mallarini, Giorgio [1 ,2 ]
机构
[1] Univ Cagliari, Dept Radiol, Policlin Univ, I-09045 Cagliari, Italy
[2] Osped San Giovanni Dio, Inst Radiol, I-09126 Cagliari, Italy
[3] Policlin Univ, Dept Vasc Surg, I-09045 Cagliari, Italy
关键词
Carotid artery; Stroke; MDCTA; CAWT; IMT; INTIMA-MEDIA THICKNESS; CARDIOVASCULAR RISK-FACTORS; ULTRASOUND MEASUREMENT; FAMILIAL HYPERCHOLESTEROLEMIA; ATHEROSCLEROTIC PLAQUES; PROGRESSION; ULTRASONOGRAPHY; REPRODUCIBILITY; POPULATION; MORPHOLOGY;
D O I
10.1007/s00234-009-0589-5
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Prospective studies have shown that an increased thickness of the carotid wall is a significant predictor of coronary and cerebrovascular complications. Our purpose was to assess the agreement between multi-detector row computed tomography (CT) angiography (MDCTA) and colour Doppler ultrasound (CD-US) in measuring carotid artery wall thickness (CAWT) and the intima-media thickness (IMT). Altogether, 97 subjects (age range 64-84 years) were prospectively analysed using a four-detector row CT and a sonographic scanner. In total, 46 subjects had shown cerebral ischaemic symptoms. CAWT and IMT were measured in each patient using MDCTA and CD-US (by applying a digital calliper), respectively. Continuous data were described as the mean value +/- standard deviation and were compared using the Mann-Whitney U test. A p value < 0.05 was considered significant. Bland-Altman statistics was employed to measure the agreement between MDCTA and CD-US. CAWT ranged from 0.5 to 1.53 mm, with a mean value of 0.9072 mm. IMT ranged from 0.46 to 1.5 mm, with a mean value of 0.8839 mm. By analysing the Bland-Altman plot, we observed an excellent agreement between CD-US and MDCTA with a bias between methods of 0.023 +/- 0.0424 mm. A limit of agreement from -0.06 to 0.106 was recorded. Correlation coefficient r was 0.9855 (95% confidence interval 0.9808-0.989). Mann-Whitney U test indicated a p value of 0.377. Obtained results indicated a significant agreement between MDCTA and CD-US in the measurement of CAWT and IMT.
引用
收藏
页码:75 / 82
页数:8
相关论文
共 50 条
  • [41] Coronal reformations of the chest on 64-row multi-detector row CT: Evaluation of image quality in comparison with 16-, 8-and 4-row multi-detector row CT
    Nishino, Mizuki
    Kubo, Takeshi
    Kataoka, Milliam L.
    Raptopoulos, Vassilios
    Hatabu, Hiroto
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2006, 59 (02) : 231 - 237
  • [42] Carotid artery stent implantation: Evaluation with multi detector row CT angiography and virtual angioscopy - Initial experience
    Orbach, DB
    Pramanik, BK
    Lee, J
    Maldonado, TS
    Riles, T
    Grossman, RI
    [J]. RADIOLOGY, 2006, 238 (01) : 309 - 320
  • [43] HYPERTENSION AND CAROTID ARTERY STENOSIS. A CORRELATIVE STUDY BY USING MULTI-DETECTOR-ROW CT ANGIOGRAPHY
    Saba, L.
    Fox, A. J.
    Sanfilippo, R.
    Montisci, R.
    Mallarini, G.
    [J]. JOURNAL OF HYPERTENSION, 2010, 28 : E312 - E312
  • [44] Agreement between multi-detector-row CT angiography and US-ECD in quantification of carotid artery stenosis and plaque characterization
    El Raouf, Sameh Abd
    El Maati, Amal Amin Abu
    Chalabi, Nivine
    [J]. EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2014, 45 (01): : 143 - 150
  • [45] Pancreas divisum: Depiction with multi-detector row CT
    Soto, JA
    Lucey, BC
    Stuhlfaut, JW
    [J]. RADIOLOGY, 2005, 235 (02) : 503 - 508
  • [46] Multi-detector row CT urography in the evaluation of hematuria
    Joffe, SA
    Servaes, S
    Okon, S
    Horowitz, M
    [J]. RADIOGRAPHICS, 2003, 23 (06) : 1441 - 1455
  • [47] Multi-detector row CT artifacts that mimic disease
    Cody, DD
    Stevens, DM
    Ginsberg, LE
    [J]. RADIOLOGY, 2005, 236 (03) : 756 - 761
  • [48] 64 Slice multi-detector row cardiac CT
    Pannu H.K.
    Johnson P.T.
    Fishman E.K.
    [J]. Emergency Radiology, 2009, 16 (1) : 1 - 10
  • [49] Short pancreas: evaluation with multi-detector row CT
    Acar, Murat
    Degirmenci, Bumin
    Tatli, Servet
    [J]. SURGICAL AND RADIOLOGIC ANATOMY, 2010, 32 (09) : 853 - 858
  • [50] Colonic distention in multi-detector row CT colonography
    Bruzzi, JF
    Fenlon, HM
    [J]. RADIOLOGY, 2004, 231 (01) : 282 - 282