Detection of submucosal gastric fundal varices with multi-detector row CT angiography

被引:52
|
作者
Willmann, JK [1 ]
Weishaupt, D [1 ]
Böhm, T [1 ]
Pfammatter, T [1 ]
Seifert, B [1 ]
Marincek, B [1 ]
Bauerfeind, P [1 ]
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
关键词
D O I
10.1136/gut.52.6.886
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and aim: The diagnosis of submucosal fundal varices is challenging. Currently, endoscopy and endoscopic ultrasound (EUS) are considered most useful for this purpose. The aim of this study was to evaluate if multi-detector row CT (MDCT) angiography contributes to the diagnosis of submucosal fundal varices. Patients and methods: Twenty two patients with endoscopically suspected fundal varices were prospectively included in the study. All patients underwent EUS and MDCT angiography. Levels of agreement between EUS and MDCT angiography for the detection of submucosal and perigastric fundal varices were evaluated by three blinded independent readers. In addition, variceal size and location, as well as afferent and efferent vessels of the submucosal varices, were determined. Results: Good or excellent image quality of MDCT angiography was obtained in 21/22 patients (95%). Based on EUS, submucosal varices were detected in 16 of 22 patients (73%) and perigastric varices in 22/22 patients (100%). Using MDCT angiography, the presence of submucosal varices was confirmed in all of these 16 patients by all three readers. Perigastric varices were also confirmed in all 22 patients by all three readers. In addition, all three readers noted the presence of a submucosal varix in an additional patient which was not detected on initial EUS. MDCT angiography showed an excellent interobserver reliability with regard to variceal diameter (kappa=0.90) and variceal location (kappa=0.94). Based on MDCT angiography, afferent and efferent vessels of submucosal varices included the left gastric vein in 11 (65%), the posterior/short gastric veins in 15 (88%), gastrorenal shunts in 10 (59%), the left inferior phrenic vein in six (35%), and the left pericardiophrenic vein in six (35%) of 17 patients. Conclusions: MDCT angiography is equivalent to EUS in terms of detection and characterisation of fundal varices, in particular with regard to the distinction between submucosal and perigastric fundal varices.
引用
收藏
页码:886 / 892
页数:7
相关论文
共 50 条
  • [1] Role of multi-detector row CT angiography in the management of gastric fundal varices
    Matsumoto, A
    Sugano, Y
    Yasuda, M
    Takimoto, K
    [J]. GUT, 2004, 53 (03) : 467 - 467
  • [2] Detection of submucosal gastric fundal varices with multidetector row CT angiography
    Willmann, JK
    Weishaupt, D
    Boehm, T
    Pfammatter, T
    Marincek, B
    Bauerfeind, P
    [J]. RADIOLOGY, 2002, 225 : 582 - 582
  • [3] Techniques for the detection of coronary atherosclerosis: Multi-detector row CT coronary angiography
    Vogl, TJ
    Abolmaali, ND
    Diebold, T
    Engelmann, K
    Ay, M
    Dogan, S
    Wimmer-Greinecker, G
    Moritz, A
    Herzog, C
    [J]. RADIOLOGY, 2002, 223 (01) : 212 - 220
  • [4] Detection of intracranial aneurysms: Multi-detector row CT angiography compared with DSA
    Jayaraman, MV
    Mayo-Smith, WW
    Tung, GA
    Haas, RA
    Rogg, JM
    Mehta, NR
    Doberstein, CE
    [J]. RADIOLOGY, 2004, 230 (02) : 510 - 518
  • [5] Multi-Detector Row CT Angiography of the Neck in Blunt Trauma
    Munera, Felipe
    Foley, Mark
    Chokshi, Falgun H.
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2012, 50 (01) : 59 - +
  • [6] Multi-detector row CT angiography in patients with abdominal angina
    Cademartiri, F
    Raaijmakers, RHJM
    Kuiper, JW
    van Dijk, LC
    Pattynama, PMT
    Krestin, GP
    [J]. RADIOGRAPHICS, 2004, 24 (04) : 969 - 984
  • [7] Diagnosis of venous thromboembolism by single-detector row and multi-detector row CT angiography
    Koyuncu, Abdullah
    Bozlar, Ugur
    Ustunsoz, Bahri
    Ors, Fatih
    Tasar, Mustafa
    Deniz, Omer
    Balkan, Arzu
    Somuncu, Ibrahim
    [J]. TUBERKULOZ VE TORAK-TUBERCULOSIS AND THORAX, 2007, 55 (01): : 24 - 33
  • [8] Multi-detector row spiral CT pulmonary angiography: Comparison with single-detector row spiral CT
    Raptopoulos, V
    Boiselle, PM
    [J]. RADIOLOGY, 2001, 221 (03) : 606 - 613
  • [9] Multi-detector row CT angiography of the brain at various kilovoltage settings
    Ertl-Wagner, BB
    Hoffmann, RT
    Bruning, R
    Herrmann, K
    Snyder, B
    Blume, JD
    Reiser, MF
    [J]. RADIOLOGY, 2004, 231 (02) : 528 - 535
  • [10] Pitfalls, artifacts, and remedies in multi-detector row CT coronary angiography
    Choi, HS
    Choi, BW
    Choe, KO
    Choi, DH
    Yoo, KJ
    Kim, MI
    Kim, J
    [J]. RADIOGRAPHICS, 2004, 24 (03) : 787 - 800