Pitfalls, artifacts, and remedies in multi-detector row CT coronary angiography

被引:71
|
作者
Choi, HS
Choi, BW
Choe, KO
Choi, DH
Yoo, KJ
Kim, MI
Kim, J
机构
[1] Yonsei Univ, Coll Med, Dept Diagnost Radiol, Seoul 120752, South Korea
[2] Yonsei Univ, Coll Med, Res Inst Radiol Sci, Seoul 120752, South Korea
[3] Yonsei Univ, Coll Med, Div Cardiol, Ctr Cardiovasc, Seoul 120752, South Korea
关键词
angiography; comparative studies; computed tomography (CT); artifact; multidetector row; coronary vessels; bypass graft; CT;
D O I
10.1148/rg.243035502
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Coronary angiography is increasingly performed with multi-detector row computed tomography (CT) in the clinical setting. Successful use of this method, however, depends on the radiologist's knowledge of its potential pitfalls and familiarity with methods for minimizing or avoiding them. To identify artifacts and other pitfalls that commonly degrade image quality and that could result in misinterpretation, contrast-enhanced coronary angiograms acquired with a multi-detector row CT scanner with four detector rows in 110 consecutive patients were analyzed. The problems identified were classified into four broad categories: (a) motion-related artifacts caused by cardiac, pulmonary, or other body motion; (b) beam-hardening effects caused by metallic implants, severe calcifications, or air bubbles in the pulmonary artery that obscured the underlying coronary vessel lumen; (c) structural artifacts produced by adjacent contrast material-filled structures and overlying vessels; and (d) artifacts that resulted from technical errors or limitations. The most frequently observed artifacts were those related to cardiac motion. The most effective methods for minimizing cardiac motion artifacts are (a) premedication with beta-blockers to maintain optimal heart rate during scanning and (b) optimal selection of the reconstruction window.
引用
收藏
页码:787 / 800
页数:14
相关论文
共 50 条
  • [1] Techniques for the detection of coronary atherosclerosis: Multi-detector row CT coronary angiography
    Vogl, TJ
    Abolmaali, ND
    Diebold, T
    Engelmann, K
    Ay, M
    Dogan, S
    Wimmer-Greinecker, G
    Moritz, A
    Herzog, C
    [J]. RADIOLOGY, 2002, 223 (01) : 212 - 220
  • [2] Multi-detector row CT artifacts that mimic disease
    Cody, DD
    Stevens, DM
    Ginsberg, LE
    [J]. RADIOLOGY, 2005, 236 (03) : 756 - 761
  • [3] Anomalous coronary arteries in adults: Depiction at multi-detector row CT angiography
    Datta, J
    White, CS
    Gilkeson, RC
    Meyer, CA
    Kansal, S
    Jani, ML
    Arildsen, RC
    Read, K
    [J]. RADIOLOGY, 2005, 235 (03) : 812 - 818
  • [4] Multi-Detector Row CT Angiography of the Neck in Blunt Trauma
    Munera, Felipe
    Foley, Mark
    Chokshi, Falgun H.
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2012, 50 (01) : 59 - +
  • [5] Multi-detector row CT angiography in patients with abdominal angina
    Cademartiri, F
    Raaijmakers, RHJM
    Kuiper, JW
    van Dijk, LC
    Pattynama, PMT
    Krestin, GP
    [J]. RADIOGRAPHICS, 2004, 24 (04) : 969 - 984
  • [6] Diagnosis of venous thromboembolism by single-detector row and multi-detector row CT angiography
    Koyuncu, Abdullah
    Bozlar, Ugur
    Ustunsoz, Bahri
    Ors, Fatih
    Tasar, Mustafa
    Deniz, Omer
    Balkan, Arzu
    Somuncu, Ibrahim
    [J]. TUBERKULOZ VE TORAK-TUBERCULOSIS AND THORAX, 2007, 55 (01): : 24 - 33
  • [7] Multi-detector row CT angiography in the assessment of coronary in-stent restenosis: A systematic review
    Sun, Zhonghua
    Davidson, Robert
    Lin, Cheng HSun
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2009, 69 (03) : 489 - 495
  • [8] Multi-detector row spiral CT pulmonary angiography: Comparison with single-detector row spiral CT
    Raptopoulos, V
    Boiselle, PM
    [J]. RADIOLOGY, 2001, 221 (03) : 606 - 613
  • [9] Multi-detector row CT angiography of the brain at various kilovoltage settings
    Ertl-Wagner, BB
    Hoffmann, RT
    Bruning, R
    Herrmann, K
    Snyder, B
    Blume, JD
    Reiser, MF
    [J]. RADIOLOGY, 2004, 231 (02) : 528 - 535
  • [10] Spontaneous coronary artery dissection: appearance and follow-up on multi-detector row CT coronary angiography
    Manghat, NE
    Morgan-Hughes, GJ
    Roobottom, CA
    [J]. CLINICAL RADIOLOGY, 2005, 60 (10) : 1120 - 1125