Impact of Window's Height on Energy Efficiency in Air-Conditioned Office Buildings

被引:0
|
作者
Al-Ashwal, Najib Taher [1 ]
Hassan, Ahmad Sanusi [1 ]
机构
[1] Univ Sains Malaysia, Sch Housing Bldg & Planning, George Town, Malaysia
关键词
Energy Efficiency; Daylighting; Window's Height; Air-Conditioned Office Buildings; DAYLIGHT; INTEGRATION;
D O I
10.1166/asl.2017.10324
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In office buildings, working spaces are mainly illuminated by artificial lighting systems which considered being responsible for a major percentage of energy consumption. It is reported that energy consumed by electrical lighting systems can reach to about 20-30% of the total energy end-use in office buildings. The efficient integration of daylighting with artificial lighting using proper lighting control system could result in a significant reduction in energy consumed. Integration of daylighting necessitates efficient window design as it provides most of the transmitted natural lighting. The height of a window has a major role in the determination of the natural light amount which is transmitted into space. Furthermore, the window's height influences the light penetration depth can be reached in the space. This paper aims to investigate the impact of window's height on the window design for energy efficiency in office buildings in a hot-humid climate. In this study, different heights of the window were analyzed with different window areas and glazing types using computer modeling and simulation. The results showed that larger window's height could result in more energy savings, due to the increase of daylight provided to the indoor space. However, the increase of the window's height to more than 1.6 m produced a slight increase in expected energy savings.
引用
收藏
页码:11540 / 11544
页数:5
相关论文
共 50 条
  • [41] Ventilation characteristics of an air-conditioned office building in Singapore
    Sekhar, SC
    Tham, KW
    Cheong, D
    [J]. BUILDING AND ENVIRONMENT, 2002, 37 (03) : 241 - 255
  • [42] Energy issues air-conditioned interiors
    Vrkoc, Michal
    Hradilek, Zdenek
    [J]. PROCEEDINGS OF THE 5TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2003, 2003, : 119 - 126
  • [43] Low-energy design for air-cooled chiller plants in air-conditioned buildings
    Yu, FW
    Chan, KT
    [J]. ENERGY AND BUILDINGS, 2006, 38 (04) : 334 - 339
  • [44] An energy impact assessment of indoor air quality acceptance for air-conditioned offices
    Wong, L. T.
    Mui, K. W.
    Shi, K. L.
    Hui, P. S.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (10) : 2815 - 2819
  • [45] Particle concentrations and sizes with normal and high efficiency air filtration in a sealed air-conditioned office building
    Fisk, WJ
    Faulkner, D
    Sullivan, D
    Mendell, MJ
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2000, 32 (06) : 527 - 544
  • [47] Optimum thermal design of air-conditioned residential buildings
    AlHomoud, MS
    [J]. BUILDING AND ENVIRONMENT, 1997, 32 (03) : 203 - 210
  • [48] Electricity consumption and built environment in air-conditioned buildings
    Lam, Joseph C.
    [J]. Energy Engineering: Journal of the Association of Energy Engineering, 1995, 92 (02): : 31 - 39
  • [49] Optimum thermal design of air-conditioned residential buildings
    King Fahd Univ of Petroleum and, Minerals, Dhahran, Saudi Arabia
    [J]. Build Environ, 3 ([d]203-210):
  • [50] Actual performance of naturally ventilated and air-conditioned Green Star certified office buildings in New Zealand
    Budin, Hemyza
    Leardini, Paola M.
    [J]. LIVING AND LEARNING: RESEARCH FOR A BETTER BUILT ENVIRONMENT, 2015, : 447 - 456