Low-energy design for air-cooled chiller plants in air-conditioned buildings

被引:10
|
作者
Yu, FW [1 ]
Chan, KT [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Hong Kong, Peoples R China
关键词
chillers; building cooling load; chilled water pumps; coefficient of performance; electricity consumption;
D O I
10.1016/j.enbuild.2005.07.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Chillers are widely used for cooling buildings in the subtropical regions at the expense of considerable energy. This paper discusses how the number and size of air-cooled chillers in a chiller plant should be designed to improve their energy performance. Using an experimentally verified chiller model, four design options were studied for a chiller plant handling the cooling load profile of an office building. Using chillers of different sizes is desirable to increase the number of steps of total cooling capacity. This enables the chillers to operate frequently at or near full load to save chiller power. Pumping energy can also be saved because of the improved control of chilled water flow whereby the chilled water supplied by the staged chillers can match with that required by air side equipment for most of the operating time. It is estimated that the annual electricity consumption of chiller plants could drop by 9.4% with the use of unequally sized chillers. The findings of this research will offer guidance on how to select chillers of different sizes for a low-energy chiller plant. (C) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:334 / 339
页数:6
相关论文
共 50 条
  • [1] An integrated model for the design of air-cooled chiller plants for commercial buildings
    Chan, Raymond K. L.
    Lee, Eric W. M.
    Yuen, Richard K. K.
    [J]. BUILDING AND ENVIRONMENT, 2011, 46 (01) : 196 - 209
  • [2] An alternative approach for the performance rating of air-cooled chillers used in air-conditioned buildings
    Yu, F. W.
    Chan, K. T.
    [J]. BUILDING AND ENVIRONMENT, 2006, 41 (12) : 1723 - 1730
  • [3] Strategy for designing more energy efficient chiller plants serving air-conditioned buildings
    Yu, F. W.
    Chan, K. T.
    [J]. BUILDING AND ENVIRONMENT, 2007, 42 (10) : 3737 - 3746
  • [4] Life cycle analysis of enhanced condenser features for air-cooled chillers serving air-conditioned buildings
    Yu, FW
    Chan, KT
    [J]. BUILDING AND ENVIRONMENT, 2006, 41 (08) : 981 - 991
  • [5] ENERGY REQUIREMENT OF AIR-CONDITIONED BUILDINGS
    ROUVEL, L
    [J]. BRENNSTOFF-WARME-KRAFT, 1973, 25 (11): : 442 - 447
  • [6] OPTIMUM DESIGN OF AIR-CONDITIONED BUILDINGS
    GUPTA, BD
    RAO, SS
    [J]. JOURNAL OF MECHANICAL DESIGN-TRANSACTIONS OF THE ASME, 1980, 102 (03): : 476 - 480
  • [7] Choice of the air-cooled chiller and the water cooled chiller
    Wu, Haicheng
    [J]. Nuantong Kongtiao/HV & AC, 1995, 25 (06): : 49 - 51
  • [8] Economic benefits of improved condenser features for air-cooled chillers serving an air-conditioned hotel
    Yu, FW
    Chan, KT
    [J]. APPLIED THERMAL ENGINEERING, 2006, 26 (10) : 1063 - 1073
  • [9] Energy simulation of sustainable air-cooled chiller system for commercial buildings under climate change
    Yu, F. W.
    Chan, K. T.
    Sit, Rachel K. Y.
    Yang, J.
    [J]. ENERGY AND BUILDINGS, 2013, 64 : 162 - 171
  • [10] Application of Numerical Simulation Technology In the large Space Air-conditioned Buildings Air-conditioned Buildings
    Li Jianwei
    Feng Zengxi
    [J]. ADVANCED DEVELOPMENT IN AUTOMATION, MATERIALS AND MANUFACTURING, 2014, 624 : 657 - 660