Impact of Window's Height on Energy Efficiency in Air-Conditioned Office Buildings

被引:0
|
作者
Al-Ashwal, Najib Taher [1 ]
Hassan, Ahmad Sanusi [1 ]
机构
[1] Univ Sains Malaysia, Sch Housing Bldg & Planning, George Town, Malaysia
关键词
Energy Efficiency; Daylighting; Window's Height; Air-Conditioned Office Buildings; DAYLIGHT; INTEGRATION;
D O I
10.1166/asl.2017.10324
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In office buildings, working spaces are mainly illuminated by artificial lighting systems which considered being responsible for a major percentage of energy consumption. It is reported that energy consumed by electrical lighting systems can reach to about 20-30% of the total energy end-use in office buildings. The efficient integration of daylighting with artificial lighting using proper lighting control system could result in a significant reduction in energy consumed. Integration of daylighting necessitates efficient window design as it provides most of the transmitted natural lighting. The height of a window has a major role in the determination of the natural light amount which is transmitted into space. Furthermore, the window's height influences the light penetration depth can be reached in the space. This paper aims to investigate the impact of window's height on the window design for energy efficiency in office buildings in a hot-humid climate. In this study, different heights of the window were analyzed with different window areas and glazing types using computer modeling and simulation. The results showed that larger window's height could result in more energy savings, due to the increase of daylight provided to the indoor space. However, the increase of the window's height to more than 1.6 m produced a slight increase in expected energy savings.
引用
收藏
页码:11540 / 11544
页数:5
相关论文
共 50 条
  • [21] Particle concentrations and sizes in an air-conditioned office with normal efficiency air filtration of University
    Fan, Yuesheng
    Si, Pengfei
    Li, Angui
    Bai, Bao
    Zhao, Xiangwei
    [J]. 2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [22] Energy use, indoor temperature and possible adaptation strategies for air-conditioned office buildings in face of global warming
    Guan, Lisa
    [J]. BUILDING AND ENVIRONMENT, 2012, 55 : 8 - 19
  • [23] The influence of internal load density on the energy and thermal performance of air-conditioned office buildings in the face of global warming
    Guan, Lisa
    [J]. ARCHITECTURAL SCIENCE REVIEW, 2015, 58 (02) : 162 - 173
  • [24] Initial study on the impact of thermal history on building occupants' thermal assessments in actual air-conditioned office buildings
    Fadeyi, Moshood Olawale
    [J]. BUILDING AND ENVIRONMENT, 2014, 80 : 36 - 47
  • [25] Daily energy consumption signatures and control charts for air-conditioned buildings
    Hitchin, Roger
    Knight, Ian
    [J]. ENERGY AND BUILDINGS, 2016, 112 : 101 - 109
  • [26] An analysis of electricity end-use in air-conditioned office buildings in Hong Kong
    Lam, JC
    Li, DHW
    Cheung, SO
    [J]. BUILDING AND ENVIRONMENT, 2003, 38 (03) : 493 - 498
  • [27] CONSISTENT PATTERN OF ELEVATED SYMPTOMS IN AIR-CONDITIONED OFFICE BUILDINGS - A REANALYSIS OF EPIDEMIOLOGIC STUDIES
    MENDELL, MJ
    SMITH, AH
    [J]. AMERICAN JOURNAL OF PUBLIC HEALTH, 1990, 80 (10) : 1193 - 1199
  • [28] A study on the identification and quantification of sources of VOCs in 5 air-conditioned Singapore office buildings
    Zuraimi, MS
    Tham, KW
    Sekhar, SC
    [J]. BUILDING AND ENVIRONMENT, 2004, 39 (02) : 165 - 177
  • [29] CONVECTIVE BODY COOLING IN AIR-CONDITIONED BUILDINGS
    CLARK, RP
    MULLAN, BJ
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1977, 267 (01): : P9 - P11
  • [30] Relationship of multiple indoor air pollutants and sick building syndrome at air-conditioned office buildings in Taiwan
    Wu, PC
    Li, YY
    Chiang, CM
    Su, HJ
    Lee, CC