Three-dimensional analysis of multiple wear vectors in retrieved acetabular cups

被引:61
|
作者
Yamaguchi, M [1 ]
Bauer, TW [1 ]
Hashimoto, Y [1 ]
机构
[1] KOBE UNIV, SCH MED, DEPT ORTHOPAED SURG, CHUO KU, KOBE, HYOGO 650, JAPAN
来源
关键词
D O I
10.2106/00004623-199710000-00011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The wear of polyethylene acetabular components is an important issue in total hip arthroplasty. The amount of wear has been measured in many studies, but few have addressed other mechanical aspects of wear in vivo. We used the shadowgraph method to measure the wear vectors in 104 retrieved acetabular cups that had been made by a single manufacturer, and we identified more than one wear vector in thirty-one cups (30 per cent). We hypothesized that the most likely explanation of multiple wear vectors was loosening of the acetabular implant with a change in the orientation of the implant in the pelvis. To test this hypothesis, we estimated the extent of motion of the cup in situ on the basis of differences in angles measured from serial radiographs of sixteen hips, We then used linear transformation of the three-dimensional vectors to compare the wear directions measured in the retrieved implants,vith the wear directions predicted from the radiographs. The change in wear direction predicted on the basis of in vivo motion of the cup never corresponded to the actual difference between wear vectors in the retrieved implants, Our results suggest that multiple wear vectors may be commonly found in retrieved implants, but loosening of the acetabular cup does not account for the multiple vectors. Additional observations suggest that impingement between the edge of the acetabular cup and the femoral component may be associated with multiple wear vectors. These results have implications for the investigation of the general mechanisms of wear in vivo and suggest that clinical or wear-testing scenarios that assume a single direction of wear may underestimate the over-all amount of volumetric wear.
引用
下载
收藏
页码:1539 / 1544
页数:6
相关论文
共 50 条
  • [1] Wear mode and wear mechanism of retrieved acetabular cups
    Yamamoto, Kengo
    Imakiire, Atsuhiro
    Masaoka, Toshinori
    Shishido, Takaaki
    Mizoue, Tatsuro
    Clarke, Ian C.
    Shoji, Hiromu
    Kawanabe, Keiichi
    Tamura, Jiro
    INTERNATIONAL ORTHOPAEDICS, 2003, 27 (05) : 286 - 290
  • [2] Wear mode and wear mechanism of retrieved acetabular cups
    Kengo Yamamoto
    Atsuhiro Imakiire
    Toshinori Masaoka
    Takaaki Shishido
    Tatsuro Mizoue
    Ian C. Clarke
    Hiromu Shoji
    Keiichi Kawanabe
    Jiro Tamura
    International Orthopaedics, 2003, 27 : 286 - 290
  • [3] POLYETHYLENE WEAR FROM RETRIEVED ACETABULAR CUPS
    WEIGHTMAN, B
    SWANSON, SAV
    ISAAC, GH
    WROBLEWSKI, BM
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05): : 806 - 810
  • [4] Polyethylene wear vector in vivo:: A three-dimensional analysis using retrieved acetabular components and radiographs
    Yamaguchi, M
    Hashimoto, Y
    Akisue, T
    Bauer, TW
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1999, 17 (05) : 695 - 702
  • [5] Wear effects in retrieved acetabular UHMW-PE cups
    Ambrosio, L
    Carotenuto, G
    Marletta, G
    Nicolais, L
    Scandurra, A
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1996, 7 (12) : 723 - 729
  • [6] Wear effects in retrieved acetabular UHMW-PE cups
    Dept. of Mat. and Prod. Engineering, University of Naples Federico II, Inst. of Compos. Mat. Technology CNR, Piazzale Tecchio, 80125 Napoli, Italy
    不详
    不详
    J. MATER. SCI. MATER. MED., 12 (723-729):
  • [7] Mechanical wear and oxidative degradation analysis of retrieved ultra high molecular weight polyethylene acetabular cups
    Choudhury, Dipankar
    Ranusa, Matus
    Fleming, Robert A.
    Vrbka, Martin
    Krupka, Ivan
    Teeter, Matthew G.
    Goss, Josh
    Zou, Min
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 79 : 314 - 323
  • [8] A new optical method for determining deformation and volumetric wear in retrieved polyethylene acetabular cups
    Thomsen, M
    Burandt, C
    Görtz, A
    Dathe, H
    Meesenburg, DK
    Spiering, S
    Görtz, W
    Näger, H
    BIOMEDIZINISCHE TECHNIK, 1999, 44 (09): : 247 - 254
  • [9] Three-dimensional computer analysis of complex acetabular insufficiency
    Roach, JW
    Hobatho, MC
    Baker, KJ
    Ashman, RB
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1997, 17 (02) : 158 - 164
  • [10] Three-dimensional stress analysis of threaded cups - a finite element analysis
    Witzel, U.
    Rieger, W.
    Effenberger, H.
    INTERNATIONAL ORTHOPAEDICS, 2008, 32 (02) : 195 - 201