Three-dimensional analysis of multiple wear vectors in retrieved acetabular cups

被引:61
|
作者
Yamaguchi, M [1 ]
Bauer, TW [1 ]
Hashimoto, Y [1 ]
机构
[1] KOBE UNIV, SCH MED, DEPT ORTHOPAED SURG, CHUO KU, KOBE, HYOGO 650, JAPAN
来源
关键词
D O I
10.2106/00004623-199710000-00011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The wear of polyethylene acetabular components is an important issue in total hip arthroplasty. The amount of wear has been measured in many studies, but few have addressed other mechanical aspects of wear in vivo. We used the shadowgraph method to measure the wear vectors in 104 retrieved acetabular cups that had been made by a single manufacturer, and we identified more than one wear vector in thirty-one cups (30 per cent). We hypothesized that the most likely explanation of multiple wear vectors was loosening of the acetabular implant with a change in the orientation of the implant in the pelvis. To test this hypothesis, we estimated the extent of motion of the cup in situ on the basis of differences in angles measured from serial radiographs of sixteen hips, We then used linear transformation of the three-dimensional vectors to compare the wear directions measured in the retrieved implants,vith the wear directions predicted from the radiographs. The change in wear direction predicted on the basis of in vivo motion of the cup never corresponded to the actual difference between wear vectors in the retrieved implants, Our results suggest that multiple wear vectors may be commonly found in retrieved implants, but loosening of the acetabular cup does not account for the multiple vectors. Additional observations suggest that impingement between the edge of the acetabular cup and the femoral component may be associated with multiple wear vectors. These results have implications for the investigation of the general mechanisms of wear in vivo and suggest that clinical or wear-testing scenarios that assume a single direction of wear may underestimate the over-all amount of volumetric wear.
引用
收藏
页码:1539 / 1544
页数:6
相关论文
共 50 条
  • [21] Characterization of dimensional, morphological and morphometric features of retrieved 3D-printed acetabular cups for hip arthroplasty
    Dall'Ava, Lorenzo
    Hothi, Harry
    Henckel, Johann
    Di Laura, Anna
    Shearing, Paul
    Hart, Alister
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [22] Characterization of dimensional, morphological and morphometric features of retrieved 3D-printed acetabular cups for hip arthroplasty
    Lorenzo Dall’Ava
    Harry Hothi
    Johann Henckel
    Anna Di Laura
    Paul Shearing
    Alister Hart
    Journal of Orthopaedic Surgery and Research, 15
  • [23] Methodology of Three-dimensional Printing in Acetabular Fractures
    Malancea, Radu Ioan
    Gavriliuc, Emanuel Robert
    Veliceasa, Bogdan
    Puha, Bogdan
    Popescu, Dragos
    Alexa, Ovidiu
    MATERIALE PLASTICE, 2017, 54 (03) : 513 - 516
  • [24] Assessment of three-dimensional acetabular coverage angles
    Upasani, Vidyadhar V.
    Bomar, James D.
    Bandaralage, Harsha
    Doan, Joshua D.
    Farnsworth, Christine L.
    JOURNAL OF HIP PRESERVATION SURGERY, 2020, 7 (02): : 305 - 312
  • [25] Three-dimensional CT analysis to determine acetabular retroversion and the implications for the management of femoro-acetabular impingement
    Dandachli, W.
    Islam, S. Ul
    Liu, M.
    Richards, R.
    Hall-Craggs, M.
    Witt, J.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (08): : 1031 - 1036
  • [26] Effect of Acetabular Reinforcement Ring With Hook for Acetabular Dysplasia Clarified by Three-Dimensional Finite Element Analysis
    Zhao, Xin
    Chosa, Etsuo
    Yamako, Go
    Watanabe, Shinji
    Deng, Gang
    Totoribe, Koji
    JOURNAL OF ARTHROPLASTY, 2013, 28 (10): : 1765 - 1769
  • [27] The development of three-dimensional imaging techniques of wear particle analysis
    Peng, Z
    Kirk, TB
    Xu, ZL
    WEAR, 1997, 203 : 418 - 424
  • [28] Three-dimensional CFD analysis for blast furnace hearth wear
    Electro-Motive Diesel Inc., LaGrange, IL
    不详
    不详
    Iron Steel Technol., 2007, 3 (43-50): : 43 - 50
  • [29] Application of a stereometric structural analysis for an evaluation of surface and for a forecast of the wear of endoprothesis acetabular cups
    Cybo, Jerzy
    Maszybrocka, Joanna
    Cwajna, Jan
    MATERIALS CHARACTERIZATION, 2006, 56 (4-5) : 363 - 372
  • [30] Three-dimensional analysis of acetabular orientation using a semi-automated algorithm
    Lee, Changhwan
    Jang, Jongseong
    Kim, Hyung Wook
    Kim, Young Soo
    Kim, Yeesuk
    COMPUTER ASSISTED SURGERY, 2019, 24 (01) : 18 - 25