A new optical method for determining deformation and volumetric wear in retrieved polyethylene acetabular cups

被引:2
|
作者
Thomsen, M
Burandt, C
Görtz, A
Dathe, H
Meesenburg, DK
Spiering, S
Görtz, W
Näger, H
机构
[1] Univ Klin Heidelberg, Stiftung Orthopad, Heidelberg, Germany
[2] Univ Gottingen, Inst Phys 4, D-3400 Gottingen, Germany
[3] Univ Gottingen, Abt Kieferorthopadie, D-3400 Gottingen, Germany
[4] Nanofilm NFT Gottingen, Gottingen, Germany
来源
BIOMEDIZINISCHE TECHNIK | 1999年 / 44卷 / 09期
关键词
new optical measuring method; polyethylene cups; total hip replacement;
D O I
10.1515/bmte.1999.44.9.247
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Aim: Most methods used for the determination of volumetric wear of polyethylene cups are based on the assumption that the head of the prosthesis penetrates the cup in "cylindrical" fashion. The new accurate optical method is independent of this disputable assumption. Method: The articulating surface of the cup is scanned with light and a data set of 60 000 pixels obtained in this way is stored in a computer. Data obtained from used cups were compared with those obtained from unused cups. The volumetric wear was calculated directly by threefold integration. To assess the changes in surface shape, the data are fitted by an ellipsoid whose long axis defines the mean direction of load. A total of 18 retrieved and 3 unused cups of different types were studied. Results: The unused acetabular cups deviated only slightly from ideal hemispheres. The surfaces showed rotational symmetry, and an undulation having an amplitude of 0.1 mm between dome and equator. For all explanted cups, the assumption of cylindrical penetration of the head into the polyethylene was shown not to represent the true situation. The cup expands in all directions, and the volumetric wear is underestimated by 50 % with the traditional methods. The data suggest that long-term survival may be jeopardized when the main direction of loading is centered on the dome of the cup. Ceramic heads were associated with smaller rates of volumetric wear. Conclusion: The new optical method is characterised by short measuring times, precision and simple application. Analysis of the wear patterns of polyethylene components using this technique may contribute to a further understanding of the complex mechanisms of aseptic loosening.
引用
收藏
页码:247 / 254
页数:8
相关论文
共 50 条
  • [1] POLYETHYLENE WEAR FROM RETRIEVED ACETABULAR CUPS
    WEIGHTMAN, B
    SWANSON, SAV
    ISAAC, GH
    WROBLEWSKI, BM
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05): : 806 - 810
  • [2] Wear mode and wear mechanism of retrieved acetabular cups
    Yamamoto, Kengo
    Imakiire, Atsuhiro
    Masaoka, Toshinori
    Shishido, Takaaki
    Mizoue, Tatsuro
    Clarke, Ian C.
    Shoji, Hiromu
    Kawanabe, Keiichi
    Tamura, Jiro
    INTERNATIONAL ORTHOPAEDICS, 2003, 27 (05) : 286 - 290
  • [3] Wear mode and wear mechanism of retrieved acetabular cups
    Kengo Yamamoto
    Atsuhiro Imakiire
    Toshinori Masaoka
    Takaaki Shishido
    Tatsuro Mizoue
    Ian C. Clarke
    Hiromu Shoji
    Keiichi Kawanabe
    Jiro Tamura
    International Orthopaedics, 2003, 27 : 286 - 290
  • [4] Wear effects in retrieved acetabular UHMW-PE cups
    Ambrosio, L
    Carotenuto, G
    Marletta, G
    Nicolais, L
    Scandurra, A
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1996, 7 (12) : 723 - 729
  • [5] Wear effects in retrieved acetabular UHMW-PE cups
    Dept. of Mat. and Prod. Engineering, University of Naples Federico II, Inst. of Compos. Mat. Technology CNR, Piazzale Tecchio, 80125 Napoli, Italy
    不详
    不详
    J. MATER. SCI. MATER. MED., 12 (723-729):
  • [6] Mechanical wear and oxidative degradation analysis of retrieved ultra high molecular weight polyethylene acetabular cups
    Choudhury, Dipankar
    Ranusa, Matus
    Fleming, Robert A.
    Vrbka, Martin
    Krupka, Ivan
    Teeter, Matthew G.
    Goss, Josh
    Zou, Min
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 79 : 314 - 323
  • [7] BIREFRINGENT STUDIES OF POLYETHYLENE WEAR SPECIMENS AND ACETABULAR CUPS
    COOPER, JR
    DOWSON, D
    FISHER, J
    WEAR, 1991, 151 (02) : 391 - 402
  • [8] Evaluation of oxidation and fatigue damage of retrieved crossfire polyethylene acetabular cups
    Currier, Barbara H.
    Currier, John H.
    Mayor, Michael B.
    Lyford, Kimberly A.
    Collier, John P.
    Van Citters, Douglas W.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (09): : 2023 - 2029
  • [9] A method for the evaluation of the change in volume of retrieved acetabular cups
    Raimondi, MT
    Sassi, R
    Pietrabissa, R
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H6) : 577 - 587
  • [10] Direct comparison of polyethylene wear in cemented and uncemented acetabular cups
    Bjerkholt H.
    Høvik Ø.
    Reikerås O.
    Journal of Orthopaedics and Traumatology, 2010, 11 (3) : 155 - 158