A new optical method for determining deformation and volumetric wear in retrieved polyethylene acetabular cups

被引:2
|
作者
Thomsen, M
Burandt, C
Görtz, A
Dathe, H
Meesenburg, DK
Spiering, S
Görtz, W
Näger, H
机构
[1] Univ Klin Heidelberg, Stiftung Orthopad, Heidelberg, Germany
[2] Univ Gottingen, Inst Phys 4, D-3400 Gottingen, Germany
[3] Univ Gottingen, Abt Kieferorthopadie, D-3400 Gottingen, Germany
[4] Nanofilm NFT Gottingen, Gottingen, Germany
来源
BIOMEDIZINISCHE TECHNIK | 1999年 / 44卷 / 09期
关键词
new optical measuring method; polyethylene cups; total hip replacement;
D O I
10.1515/bmte.1999.44.9.247
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Aim: Most methods used for the determination of volumetric wear of polyethylene cups are based on the assumption that the head of the prosthesis penetrates the cup in "cylindrical" fashion. The new accurate optical method is independent of this disputable assumption. Method: The articulating surface of the cup is scanned with light and a data set of 60 000 pixels obtained in this way is stored in a computer. Data obtained from used cups were compared with those obtained from unused cups. The volumetric wear was calculated directly by threefold integration. To assess the changes in surface shape, the data are fitted by an ellipsoid whose long axis defines the mean direction of load. A total of 18 retrieved and 3 unused cups of different types were studied. Results: The unused acetabular cups deviated only slightly from ideal hemispheres. The surfaces showed rotational symmetry, and an undulation having an amplitude of 0.1 mm between dome and equator. For all explanted cups, the assumption of cylindrical penetration of the head into the polyethylene was shown not to represent the true situation. The cup expands in all directions, and the volumetric wear is underestimated by 50 % with the traditional methods. The data suggest that long-term survival may be jeopardized when the main direction of loading is centered on the dome of the cup. Ceramic heads were associated with smaller rates of volumetric wear. Conclusion: The new optical method is characterised by short measuring times, precision and simple application. Analysis of the wear patterns of polyethylene components using this technique may contribute to a further understanding of the complex mechanisms of aseptic loosening.
引用
收藏
页码:247 / 254
页数:8
相关论文
共 50 条
  • [31] Dual articulation retentive acetabular liners and wear: surface analysis of 40 retrieved polyethylene implants
    Adam, P
    Farizon, F
    Fessy, MH
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2005, 91 (07): : 627 - 636
  • [32] Influence of a foreign body on the wear of metallic femoral heads and polyethylene acetabular cups of total hip prostheses
    D. Najjar
    A. Behnamghader
    A. Iost
    H. Migaud
    Journal of Materials Science, 2000, 35 : 4583 - 4588
  • [33] MEASUREMENT OF POLYETHYLENE WEAR IN METAL-BACKED ACETABULAR CUPS .2. CLINICAL-APPLICATION
    DEVANE, PA
    BOURNE, RB
    RORABECK, CH
    MACDONALD, S
    ROBINSON, EJ
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (319) : 317 - 326
  • [34] Influence of a foreign body on the wear of metallic femoral heads and polyethylene acetabular cups of total hip prostheses
    Najjar, D
    Behnamghader, A
    Iost, A
    Migaud, H
    JOURNAL OF MATERIALS SCIENCE, 2000, 35 (18) : 4583 - 4588
  • [35] WEAR OF POLYETHYLENE ACETABULAR CUPS AGAINST ZIRCONIA FEMORAL HEADS STUDIED WITH A HIP-JOINT SIMULATOR
    SAIKKO, V
    WEAR, 1994, 176 (02) : 207 - 212
  • [36] A Novel Method for Assessment of Polyethylene Liner Wear in Radiopaque Tantalum Acetabular Cups: Clinical Validation in Patients Enrolled in a Randomized Controlled Trial
    Troelsen, Anders
    Greene, Meridith E.
    Ayers, David C.
    Bragdon, Charles R.
    Malchau, Henrik
    JOURNAL OF ARTHROPLASTY, 2015, 30 (12): : 2354 - 2359
  • [37] Effects of the sterilisation method on the wear of UHMWPE acetabular cups tested in a hip joint simulator
    Affatato, S
    Bordini, B
    Fagnano, C
    Taddei, P
    Tinti, A
    Toni, A
    BIOMATERIALS, 2002, 23 (06) : 1439 - 1446
  • [38] Validation of a 3D CT method for measurement of linear wear of acetabular cups
    Jedenmalm, Anneli
    Nilsson, Fritjof
    Noz, Marilyn E.
    Green, Douglas D.
    Gedde, Ulf W.
    Clarke, Ian C.
    Stark, Andreas
    Maguire, Gerald Q., Jr.
    Zeleznik, Michael P.
    Olivecrona, Henrik
    ACTA ORTHOPAEDICA, 2011, 82 (01) : 35 - 41
  • [39] Polyethylene wear vector in vivo:: A three-dimensional analysis using retrieved acetabular components and radiographs
    Yamaguchi, M
    Hashimoto, Y
    Akisue, T
    Bauer, TW
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1999, 17 (05) : 695 - 702
  • [40] Validation of a new 2-D technique for radiographic wear measurement of cemented, highly cross-linked polyethylene acetabular cups
    Derbyshire, Brian
    Barkatali, Bilal
    MEDICAL ENGINEERING & PHYSICS, 2017, 47 : 159 - 166