Characterization of a full field digital mammography detector based on direct x-ray conversion in selenium

被引:41
|
作者
Yorker, JG [1 ]
Jeromin, LS [1 ]
Lee, DLY [1 ]
Palecki, EF [1 ]
Golden, KP [1 ]
Jing, ZX [1 ]
机构
[1] Direct Radiog, Newark, DE 19702 USA
关键词
digital mammography; direct x-ray detector; selenium; MTF; DQE;
D O I
10.1117/12.465568
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We describe a high-resolution digital x-ray detector suitable for producing high quality mammographic images. The detector consists of an array of 3584 by 4096 pixels on 70 micrometer centers covering an area of 25 cm by 29 cm. The conversion layer of the detector is 250 micrometer thick amorphous selenium. Each pixel of the array consists of a storage capacitor for collecting x-ray signals and an amorphous silicon switching transistor. The signal is read out by custom high-speed, low-noise electronics. The integration of this detector with a mammographic x-ray system and acquisition console is described, as well as algorithms for calibration of the full system. We review characterization of the imaging performance of our system based on quantitative analyses of MTF and DQE data, and compare experimental results with theoretical calculations. We compare the performance of our direct conversion system with that of screen/film analog systems and indirect conversion digital detectors, such as LORAD's CsI/CCD detector, operated under similar conditions. MTF degradation mechanisms and system noise sources and their effect on DQE are discussed. We review qualitative aspects of image quality from our detector and present preliminary observer performance characteristics on clinical studies run with our system.
引用
收藏
页码:21 / 29
页数:3
相关论文
共 50 条
  • [41] X-ray detection method for the direct-conversion plasma detector
    Kang, Jungwon
    Shin, Hyungsup
    Lee, Sangjun
    Lee, Kisung
    Lee, Hakjae
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XII, 2010, 7805
  • [42] CMOS direct conversion X-ray detector coupled with fluorinated liquid
    ShiHua Liu
    ChaoSong Gao
    Xin Zhang
    XiangMing Sun
    Meng Wu
    ZhiHui Han
    Tong Wan
    YongShuai Ge
    Nuclear Science and Techniques, 2025, 36 (01) : 5 - 14
  • [43] Direct-conversion x-ray imaging detector improvements and observations
    Lee, DLY
    Lui, C
    Golden, KP
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS V, 2003, 5199 : 162 - 166
  • [44] Cmos direct conversion X-ray detector coupled with fluorinated liquid
    Liu, Shi-Hua
    Gao, Chao-Song
    Zhang, Xin
    Sun, Xiang-Ming
    Wu, Meng
    Han, Zhi-Hui
    Wan, Tong
    Ge, Yong-Shuai
    NUCLEAR SCIENCE AND TECHNIQUES, 2025, 36 (01)
  • [45] Direct selenium x-ray detector for fluoroscopy, R&F, and radiography
    Choquette, M
    Rougeot, H
    Martin, JP
    Laperrière, L
    Shukri, Z
    Polischuk, B
    MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 : 128 - 136
  • [46] Hard X-ray full-field nanoimaging using a direct photon-counting detector
    Flenner, Silja
    Hagemann, Johannes
    Wittwer, Felix
    Longo, Elena
    Kubec, Adam
    Rothkirch, Andre
    David, Christian
    Mueller, Martin
    Greving, Imke
    JOURNAL OF SYNCHROTRON RADIATION, 2023, 30 : 390 - 399
  • [47] Digital mammography in direct magnification technique using a large-area amorphous silicon X-ray detector.
    Hermann, KP
    Hundertmark, C
    Funke, M
    von Brenndorff, A
    Grabbe, E
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (05): : 503 - 506
  • [48] Evaluation based on breast tomosynthesis of amorphous selenium full field digital mammography system
    Varjonen, M
    Strommer, P
    MEDICAL PHYSICS, 2005, 32 (06) : 1897 - 1897
  • [49] Modeling Noise Properties of A High Resolution CMOS Detector for X-ray Digital Mammography
    Kalyvas, N.
    Michail, C.
    Fountos, G.
    Valais, I.
    Liaparinos, P.
    Seferis, I.
    Spyropoulou, V.
    Mytafidis, A.
    Panayiotakis, G.
    Kandarakis, I.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2465 - 2470
  • [50] Experimental investigations of image quality in X-ray mammography with a conventional screen film system (SFS) and a new full-field digital mammography unit (DR) with a-Se-detector
    Schulz-Wendtland, R
    Wenkel, E
    Schmid, A
    Imhoff, K
    Bautz, W
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (06): : 766 - 768