Experimental investigations of image quality in X-ray mammography with a conventional screen film system (SFS) and a new full-field digital mammography unit (DR) with a-Se-detector

被引:0
|
作者
Schulz-Wendtland, R [1 ]
Wenkel, E [1 ]
Schmid, A [1 ]
Imhoff, K [1 ]
Bautz, W [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Diagnost Radiol, D-91054 Erlangen, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2003年 / 175卷 / 06期
关键词
mammography; digital mammography; phantom study;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Determination of image quality of a new digital mammography system with an a-Se-detector. Material and Method: Radiograms of the Wisconsin Mammographic Random Phantom, Modell 152 A (Radiation Measurements Inc., Wisconsin) were acquired using a conventional film screen and a digital system. Results: With the conventional film screen system there were detected 191/a 38.2 and with the digital mammography 219/a 43.8 of 225 possible details. Conclusion: Based on these results there is the possibility to replace the conventional film screen system by the digital mammography with a-Se-detector - this has to be confirmed in further clinical trials.
引用
收藏
页码:766 / 768
页数:3
相关论文
共 46 条
  • [1] Comparison of a new full-field digital mammography system and conventional film-screen mammography: A phantom study
    Bick, U
    Diekmann, F
    Marth, F
    Le Roux, A
    Juran, R
    Friedrich, M
    RADIOLOGY, 1999, 213P : 152 - 152
  • [2] Comparison of full-field digital mammography and film-screen mammography:: image quality and lesion detection
    Fischmann, A
    Siegmann, KC
    Wersebe, A
    Claussen, CD
    Müller-Schimpfle, M
    BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (928): : 312 - 315
  • [3] Adaptive image interpolation for full-field digital x-ray mammography
    Liu, H
    Wang, G
    Xu, F
    Fajardo, LL
    APPLIED OPTICS, 1999, 38 (01) : 253 - 257
  • [4] X-ray scattering in full-field digital mammography
    Nykänen, K
    Siltanen, S
    MEDICAL PHYSICS, 2003, 30 (07) : 1864 - 1873
  • [5] Radiation exposure in full-field digital mammography with a flat-panel x-ray detector based on amorphous silicon in comparison with conventional screen-film mammography.
    Hermann, KP
    Obenauer, S
    Grabbe, E
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (11): : 940 - 945
  • [6] Screen film vs full-field digital mammography: image quality, detectability and characterization of lesions
    S. Obenauer
    S. Luftner-Nagel
    D. von Heyden
    U. Munzel
    F. Baum
    E. Grabbe
    European Radiology, 2002, 12 : 1697 - 1702
  • [7] Screen film vs full-field digital mammography: image quality, detectability and characterization of lesions
    Obenauer, S
    Luftner-Nagel, S
    von Heyden, D
    Munzel, U
    Baum, F
    Grabbe, E
    EUROPEAN RADIOLOGY, 2002, 12 (07) : 1697 - 1702
  • [8] Contrast-detail-resolution of full-field digital mammography in comparison to conventional film-screen mammography
    Bick, U
    Diekmann, F
    Grebe, S
    Marth, F
    Juran, R
    Friedrich, M
    IWDM 2000: 5TH INTERNATIONAL WORKSHOP ON DIGITAL MAMMOGRAPHY, 2001, : 627 - 632
  • [9] Visualization of microcalcifications on mammographies obtained by digital full-field mammography in comparison to conventional film-screen mammography
    Diekmann, S
    Bick, U
    von Heyden, H
    Diekmann, F
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (06): : 775 - 779
  • [10] Visualization of microcalcifications on mammographies obtained by digital full-field mammography in comparison to conventional film-screen mammography
    Diekmann, SD
    Von Heyden, H
    Bick, U
    Von Heyden, D
    Luftner-Nagel, S
    Hamm, BK
    RADIOLOGY, 2002, 225 : 416 - 416