Experimental investigations of image quality in X-ray mammography with a conventional screen film system (SFS) and a new full-field digital mammography unit (DR) with a-Se-detector

被引:0
|
作者
Schulz-Wendtland, R [1 ]
Wenkel, E [1 ]
Schmid, A [1 ]
Imhoff, K [1 ]
Bautz, W [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Diagnost Radiol, D-91054 Erlangen, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2003年 / 175卷 / 06期
关键词
mammography; digital mammography; phantom study;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Determination of image quality of a new digital mammography system with an a-Se-detector. Material and Method: Radiograms of the Wisconsin Mammographic Random Phantom, Modell 152 A (Radiation Measurements Inc., Wisconsin) were acquired using a conventional film screen and a digital system. Results: With the conventional film screen system there were detected 191/a 38.2 and with the digital mammography 219/a 43.8 of 225 possible details. Conclusion: Based on these results there is the possibility to replace the conventional film screen system by the digital mammography with a-Se-detector - this has to be confirmed in further clinical trials.
引用
收藏
页码:766 / 768
页数:3
相关论文
共 46 条
  • [41] Image-quality performance of an a-Si: H-based X-ray imaging system for digital mammography
    Darambara, DG
    Taibi, A
    Speller, RD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3): : 521 - 526
  • [42] Image quality assessment via segmentation of breast lesion in X-ray and ultrasound phantom images from Fischer's full field digital mammography and ultrasound (FFDMUS) system
    Suri, J
    Guo, YJ
    Coad, C
    Danielson, T
    Elbakri, L
    Janer, R
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2005, 4 (01) : 83 - 92
  • [43] Two-View and Single-View Tomosynthesis versus Full-Field Digital Mammography: High-Resolution X-Ray Imaging Observer Study
    Wallis, Matthew G.
    Moa, Elin
    Zanca, Federica
    Leifland, Karin
    Danielsson, Mats
    RADIOLOGY, 2012, 262 (03) : 788 - 796
  • [44] Comparison of a digital flat panel, x-ray image intensifier and conventional film-screen system for radiostereometric analysis (RSA)
    Yuan, XH
    Drangova, M
    Pollmann, S
    Miron, R
    Bourne, R
    Holdsworth, DW
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 914 - 921
  • [45] Pilot Study on the Detection of Simulated Lesions Using a 2D and 3D Digital Full-Field Mammography System with a Newly Developed High Resolution Detector Based on Two Shifts of a-Se
    Schulz-Wendtland, R.
    Bani, M.
    Lux, M. P.
    Schwab, S.
    Loehberg, C. R.
    Jud, S. M.
    Rauh, C.
    Bayer, C. M.
    Beckmann, M. W.
    Uder, M.
    Fasching, P. A.
    Adamietz, B.
    Meier-Meitinger, M.
    GEBURTSHILFE UND FRAUENHEILKUNDE, 2012, 72 (05) : 408 - 411
  • [46] Image quality evaluation of a new selenium-based flat-panel digital X-ray detector system at low- dose fluoroscopic rate
    Yamada, S
    Nagai, S
    Honda, M
    Yang, CJ
    Bednarek, DR
    Rudin, S
    RADIOLOGY, 1999, 213P : 236 - 236