Pilot Study on the Detection of Simulated Lesions Using a 2D and 3D Digital Full-Field Mammography System with a Newly Developed High Resolution Detector Based on Two Shifts of a-Se

被引:8
|
作者
Schulz-Wendtland, R. [1 ]
Bani, M. [2 ]
Lux, M. P. [2 ]
Schwab, S. [1 ]
Loehberg, C. R. [2 ]
Jud, S. M. [2 ]
Rauh, C. [2 ]
Bayer, C. M. [2 ]
Beckmann, M. W. [2 ]
Uder, M. [1 ]
Fasching, P. A. [2 ]
Adamietz, B. [1 ]
Meier-Meitinger, M. [1 ]
机构
[1] Universitatsklinikum Erlangen, Inst Radiol, D-91054 Erlangen, Germany
[2] Universitatklinikum Erlangen, Frauenklin, Erlangen, Germany
关键词
breast; breast tumor; mammographic density; BREAST TOMOSYNTHESIS; FILM MAMMOGRAPHY; CANCER; PERFORMANCE; EXPERIENCE; OBSERVER;
D O I
10.1055/s-0031-1298158
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Purpose: Experimental study of a new system for digital 2D and 3D full-field mammography (FFDM) using a high resolution detector based on two shifts of a-Se. Material and Methods: Images were acquired using the new FFDM system Amulet (R) (FujiFilm, Tokio, Japan), an a-Se detector (receptor 24 x 30 cm(2), pixel size 50 mu m, memory depth 12 bit, spatial resolution 10 lp/mm, DQE > 0.50). Integrated in the detector is a new method for data transfer, based on optical switch technology. The object of investigation was the Wisconsin Mammographic Random Phantom, Model 152A (Radiation Measurement Inc., Middleton, WI, USA) and the same parameters and exposure data (Tungsten, 100 mAs, 30 kV) were consistently used. We acquired 3 different pairs of images in the c-c and ml planes (2D) and in the c-c and c-c planes with an angle of 4 degrees (3D). Five radiologists experienced in mammography (experience ranging from 3 months to more than 5 years) analyzed the images (monitoring) which had been randomly encoded (random generator) with regard to the recognition of details such as specks of aluminum oxide (200-740 mu m), nylon fibers (0.4-1.6 mm) and round lesions/masses (diameters 5-14 mm), using special linear glasses for 3D visualization, and compared the results. Results: A total of 225 correct positive decisions could be detected: we found 222 (98.7%) correct positive results for 2D and 3D visualization in each case. Conclusion: The results of this phantom study showed the same detection rates for both 2D and 3D imaging using full field digital mammography. Our results must be confirmed in further clinical trials.
引用
收藏
页码:408 / 411
页数:4
相关论文
共 2 条
  • [1] The small-size details detection performance of digital breast tomosynthesis, synthetic 2D and conventional full-field digital mammography images for different mammography systems: a multicenter study.
    Ravaglia, V
    Angelini, L.
    Bertolini, M.
    Della Gala, G.
    Fabbri, C.
    Fabbri, S.
    Farnedi, S.
    Vacchieri, I
    Golinelli, P.
    Guerra, G.
    Ortenzia, O.
    Pagan, L.
    Savini, A.
    Scrittori, N.
    Venturi, G.
    15TH INTERNATIONAL WORKSHOP ON BREAST IMAGING (IWBI2020), 2020, 11513
  • [2] 2D building change detection from high resolution satellite imagery: A two-step hierarchical method based on 3D invariant primitives
    Champion, Nicolas
    Boldo, Didier
    Pierrot-Deseilligny, Marc
    Stamon, Georges
    PATTERN RECOGNITION LETTERS, 2010, 31 (10) : 1138 - 1147