Two-View and Single-View Tomosynthesis versus Full-Field Digital Mammography: High-Resolution X-Ray Imaging Observer Study

被引:151
|
作者
Wallis, Matthew G. [1 ]
Moa, Elin [2 ]
Zanca, Federica [3 ]
Leifland, Karin [4 ]
Danielsson, Mats [5 ]
机构
[1] Cambridge Univ Hosp NHS Fdn Trust, Cambridge Breast Unit, Cambridge CB2 0QQ, England
[2] Philips Womens Imaging Healthcare, Solna, Sweden
[3] Univ Louvain, Ctr Med Phys Radiol, Univ Hosp Leuven, Louvain, Belgium
[4] Capio St Gorans Hosp, Unilabs AB, Mammog Dept, Stockholm, Sweden
[5] Royal Inst Technol, Dept Phys, S-10044 Stockholm, Sweden
关键词
SCREEN-FILM MAMMOGRAPHY; BREAST TOMOSYNTHESIS; PERFORMANCE; POPULATION; EXPERIENCE; ACCURACY;
D O I
10.1148/radiol.11103514
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the diagnostic accuracy of two-dimensional (2D) full-field digital mammography with that of two-view (mediolateral and craniocaudal) and single-view (mediolateral oblique) tomosynthesis in an observer study involving two institutions. Materials and Methods: Ethical committee approval was obtained. All participating women gave informed consent. Two hundred twenty women (mean age, 56.3; range, 40-80 years) with breast density of 2-4 according to American College of Radiology criteria were recruited between November 2008 and September 2009 and underwent standard treatment plus tomosynthesis with a prototype photon-counting machine. After exclusion criteria were met, this resulted in a final test set of 130 women. Ten accredited readers classified the 130 cases (40 cancers, 24 benign lesions, and 66 normal images) using 2D mammography and two-view tomosynthesis. Another 10 readers reviewed the same cases using 2D mammography but single-view tomosynthesis. The multireader, multicase receiver operating characteristic (ROC) method was applied. The significance of the observed difference in accuracy between 2D mammography and tomosynthesis was calculated. Results: For diagnostic accuracy, 2D mammography performed significantly worse than two-view tomosynthesis (average area under ROC curve [AUC] = 0.772 for 2D, AUC = 0.851 for tomosynthesis, P = .021). Significant differences were found for both masses and microcalcification (P = .037 and .049). The difference in AUC between the two modalities of 20.110 was significant (P = .03) only for the five readers with the least experience (<10 years of reading); with AUC of 20.047 for the five readers with 10 years or more experience (P = .25). No significant difference (P = .79) in reader performance was seen when 2D mammography (average AUC = 0.774) was compared with single-view tomosynthesis (average AUC = 0.775). Conclusion: Two-view tomosynthesis outperforms 2D mammography but only for readers with the least experience. The benefits were seen for both masses and microcalcification. No differences in classification accuracy was seen between and 2D mammography and single-view tomosynthesis.
引用
收藏
页码:788 / 796
页数:9
相关论文
共 50 条
  • [1] Performance comparison of single-view digital breast tomosynthesis plus single-view digital mammography with two-view digital mammography
    Gisella Gennaro
    R. Edward Hendrick
    Patricia Ruppel
    Roberta Chersevani
    Cosimo di Maggio
    Manuela La Grassa
    Luigi Pescarini
    Ilaria Polico
    Alessandro Proietti
    Enrica Baldan
    Elisabetta Bezzon
    Fabio Pomerri
    Pier Carlo Muzzio
    European Radiology, 2013, 23 : 664 - 672
  • [2] Performance comparison of single-view digital breast tomosynthesis plus single-view digital mammography with two-view digital mammography
    Gennaro, Gisella
    Hendrick, R. Edward
    Ruppel, Patricia
    Chersevani, Roberta
    di Maggio, Cosimo
    La Grassa, Manuela
    Pescarini, Luigi
    Polico, Ilaria
    Proietti, Alessandro
    Baldan, Enrica
    Bezzon, Elisabetta
    Pomerri, Fabio
    Muzzio, Pier Carlo
    EUROPEAN RADIOLOGY, 2013, 23 (03) : 664 - 672
  • [3] Comparison of two-view versus single-view digital breast tomosynthesis and 2D-mammography in breast cancer surveillance imaging
    Hadjipanteli, Andria
    Polyviou, Petros
    Kyriakopoulos, Ilias
    Genagritis, Marios
    Kotziamani, Natasa
    Moniatis, Demetris
    Papoutsou, Anne
    Constantinidou, Anastasia
    PLOS ONE, 2021, 16 (09):
  • [4] Review of radiation dose estimates in digital breast tomosynthesis relative to those in two-view full-field digital mammography
    Svahn, T. M.
    Houssami, N.
    Sechopoulos, I.
    Mattsson, S.
    BREAST, 2015, 24 (02): : 93 - 99
  • [5] Two-view 2D digital mammography versus one-view digital breast tomosynthesis
    Michell, M. J.
    Wasan, R. K.
    Iqbal, A.
    Peacock, C.
    Evans, D. R.
    Morel, J. C.
    BREAST CANCER RESEARCH, 2010, 12
  • [6] Two-view 2D digital mammography versus one-view digital breast tomosynthesis
    MJ Michell
    RK Wasan
    A Iqbal
    C Peacock
    DR Evans
    JC Morel
    Breast Cancer Research, 12
  • [7] The diagnostic accuracy of dual-view digital mammography, single-view breast tomosynthesis and a dual-view combination of breast tomosynthesis and digital mammography in a free-response observer performance study
    Svahn, T.
    Andersson, I.
    Chakraborty, D.
    Svensson, S.
    Ikeda, D.
    Fornvik, D.
    Mattsson, S.
    Tingberg, A.
    Zackrisson, S.
    RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) : 113 - 117
  • [8] Detection and characterization of breast lesions in a selective diagnostic population: diagnostic accuracy study for comparison between one-view digital breast tomosynthesis and two-view full-field digital mammography
    Chae, Eun Young
    Kim, Hak Hee
    Cha, Joo Hee
    Shin, Hee Jung
    Choi, Woo Jung
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1062):
  • [9] Two-view versus single-view mammography at subsequent screening in a region of the Dutch breast screening programme
    Smallenburg, Vivian van Breest
    Duijm, Lucien E. M.
    den Heeten, Gerard J.
    Groenewoud, Johanna H.
    Jansen, Frits H.
    Fracheboud, Jacques
    Plaisier, Menno L.
    van Doorne-Nagtegaal, Heidi J.
    Broeders, Mireille J. M.
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (09) : 2189 - 2194
  • [10] X-ray scattering in full-field digital mammography
    Nykänen, K
    Siltanen, S
    MEDICAL PHYSICS, 2003, 30 (07) : 1864 - 1873