One-Component Revision of Failed Hip Resurfacing from Adverse Reaction to Metal Wear Debris

被引:35
|
作者
Pritchett, James W.
机构
来源
JOURNAL OF ARTHROPLASTY | 2014年 / 29卷 / 01期
关键词
total hip arthroplasty; revision; hip resurfacing; wear debris; ARTHROPLASTY; REPLACEMENT; FAILURE; PSEUDOTUMOR; END;
D O I
10.1016/j.arth.2013.04.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study assessed the results of 90 one-component revisions for failed hip resurfacing due to adverse reaction to metal wear debris (76 acetabular, 14 femoral). Patients with a femoral head size 40-45 mm (n = 33) received a two-piece titanium meshed shell with a cross-linlced polyethylene liner and patients with femoral head size 46-54 mm (n = 43) received metal-on-metal components. Patients with femoral head size >45 mm who wished a metal-polyethylene bearing received a dual mobility femoral prosthesis. The mean follow-up was 61 months and the procedure was successful in 97% of the patients. Three failures required re-revision; there was one deep infection. There were no dislocations. One-component revision is a reasonable alternative to revision to total hip arthroplasty. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:219 / 224
页数:6
相关论文
共 50 条
  • [31] Characterization of wear debris from metal-on-metal hip implants during normal wear versus edge-loading conditions
    Kovochich, Michael
    Fung, Ernest S.
    Donovan, Ellen
    Unice, Kenneth M.
    Paustenbach, Dennis J.
    Finley, Brent L.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2018, 106 (03) : 986 - 996
  • [32] Adverse reaction to metal debris after small-head diameter metal-on-metal total hip arthroplasty: an increasing concern
    D'Angelo, Fabio
    Tanas, Davide
    Gallazzi, Enrico
    Zagra, Luigi
    [J]. HIP INTERNATIONAL, 2018, 28 : 35 - 42
  • [33] Adverse reaction to metal release from a modular metal-on-polyethylene hip prosthesis
    Lindgren, J. U.
    Brismar, B. H.
    Wikstrom, A. C.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (10): : 1427 - 1430
  • [34] Blood Metal Ion Thresholds to Identify Patients with Metal-on-Metal Hip Implants at Risk of Adverse Reactions to Metal Debris An External Multicenter Validation Study of Birmingham Hip Resurfacing and Corail-Pinnacle Implants
    Matharu, Gulraj S.
    Berryman, Fiona
    Judge, Andrew
    Reito, Aleksi
    McConnell, Jamie
    Lainiala, Olli
    Young, Stephen
    Eskelinen, Antti
    Pandit, Hemant G.
    Murray, David W.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (18): : 1532 - 1539
  • [35] No Threshold Exists for Recommending Revision Surgery in Metal-on-Metal Hip Arthroplasty Patients With Adverse Reactions to Metal Debris: A Retrospective Cohort Study of 346 Revisions
    Matharu, Gulraj S.
    Berryman, Fiona
    Dunlop, David J.
    Revell, Matthew P.
    Judge, Andrew
    Murray, David W.
    Pandit, Hemant G.
    [J]. JOURNAL OF ARTHROPLASTY, 2019, 34 (07): : 1483 - 1491
  • [36] Outcome of Re-Revision Surgery for Adverse Local Tissue Reaction in Metal-on-Polyethylene and Metal-on-Metal Total Hip Arthroplasty
    Bonner, Bryant
    Arauz, Paul
    Klemt, Christian
    Kwon, Young-Min
    [J]. JOURNAL OF ARTHROPLASTY, 2020, 35 (06): : S284 - S288
  • [37] Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in metal on metal total hip replacements
    Tipper, JL
    Firkins, PJ
    Ingham, E
    Fisher, J
    Stone, MH
    Farrar, R
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1999, 10 (06) : 353 - 362
  • [38] Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in metal on metal total hip replacements
    J. L. Tipper
    P. J. Firkins
    E. Ingham
    J. Fisher
    M. H. Stone
    R. Farrar
    [J]. Journal of Materials Science: Materials in Medicine, 1999, 10 : 353 - 362
  • [39] Which factors influence the rate of failure following metal-on-metal hip arthroplasty revision surgery performed for adverse reactions to metal debris? AN ANALYSIS FROM THE NATIONAL JOINT REGISTRY FOR ENGLAND AND WALES
    Matharu, G. S.
    Judge, A.
    Pandit, H. G.
    Murray, D. W.
    [J]. BONE & JOINT JOURNAL, 2017, 99B (08): : 1020 - 1027
  • [40] The sensitivity, specificity and predictive values of raised plasma metal ion levels in the diagnosis of adverse reaction to metal debris in symptomatic patients with a metal-on-metal arthroplasty of the hip
    Malek, I. A.
    King, A.
    Sharma, H.
    Malek, S.
    Lyons, K.
    Jones, S.
    John, A.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (08): : 1045 - 1050