The sensitivity, specificity and predictive values of raised plasma metal ion levels in the diagnosis of adverse reaction to metal debris in symptomatic patients with a metal-on-metal arthroplasty of the hip

被引:75
|
作者
Malek, I. A. [1 ]
King, A. [1 ]
Sharma, H. [1 ]
Malek, S. [1 ]
Lyons, K. [1 ]
Jones, S. [1 ]
John, A. [1 ]
机构
[1] Univ Wales Hosp, Cardiff CF14 4XW, S Glam, Wales
来源
关键词
RESURFACING ARTHROPLASTY; FOLLOW-UP; REPLACEMENT; COMPONENT; BEARINGS; WEAR; PSEUDOTUMORS; ORIENTATION; IMPLANTS; ARTIFACT;
D O I
10.1302/0301-620X.94B8.27626
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Plasma levels of cobalt and chromium ions and Metal Artefact Reduction Sequence (MARS)-MRI scans were performed on patients with 209 consecutive, unilateral, symptomatic metal-on-metal (MoM) hip arthroplasties. There was wide variation in plasma cobalt and chromium levels, and MARS-MRI scans were positive for adverse reaction to metal debris (ARMD) in 84 hips (40%). There was a significant difference in the median plasma cobalt and chromium levels between those with positive and negative MARS-MRI scans (p < 0.001). Compared with MARS-MRI as the potential reference standard for the diagnosis of ARMD, the sensitivity of metal ion analysis for cobalt or chromium with a cut-off of > 7 mu g/l was 57%. The specificity was 65%, positive predictive value was 52% and the negative predictive value was 69% in symptomatic patients. A lowered threshold of > 3.5 mu g/l for cobalt and chromium ion levels improved the sensitivity and negative predictive value to 86% and 74% but at the expense of specificity (27%) and positive predictive value (44%). Metal ion analysis is not recommended as a sole indirect screening test in the surveillance of symptomatic patients with a MoM arthroplasty. The investigating clinicians should have a low threshold for obtaining cross-sectional imaging in these patients, even in the presence of low plasma metal ion levels.
引用
收藏
页码:1045 / 1050
页数:6
相关论文
共 50 条
  • [1] Predictive factors for metal ion levels in metal-on-metal total hip arthroplasty
    Maximilian F. Kasparek
    Lisa Renner
    Martin Faschingbauer
    Wenzel Waldstein
    Michael Weber
    Friedrich Boettner
    [J]. Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 281 - 286
  • [2] Predictive factors for metal ion levels in metal-on-metal total hip arthroplasty
    Kasparek, Maximilian F.
    Renner, Lisa
    Faschingbauer, Martin
    Waldstein, Wenzel
    Weber, Michael
    Boettner, Friedrich
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (02) : 281 - 286
  • [3] Metal ion levels in a triathlete with a metal-on-metal resurfacing arthroplasty of the hip
    De Haan, R.
    Campbell, P.
    Reid, S.
    Skipor, A. K.
    De Smet, K.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (04): : 538 - 541
  • [4] Metal ion hypersensitivity in metal-on-metal hip arthroplasty
    Park, Y. -S.
    Moon, Y. -W.
    Lim, S. -J.
    [J]. BIOCERAMICS AND ALTERNATIVE BEARINGS IN JOINT ARTHROPLASTY, 2006, : 57 - +
  • [5] Immune response in adverse reactions to metal debris following metal-on-metal total hip arthroplasty
    Masahiro Hasegawa
    Takahiro Iino
    Akihiro Sudo
    [J]. BMC Musculoskeletal Disorders, 17
  • [6] Immune response in adverse reactions to metal debris following metal-on-metal total hip arthroplasty
    Hasegawa, Masahiro
    Iino, Takahiro
    Sudo, Akihiro
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2016, 17
  • [7] The value of serial metal ion levels in following up patients with metal-on-metal hip arthroplasty
    McHugh, Gavin
    Merchant, Rajiv
    Kelly, Gabrielle E.
    Bergin, Karen M.
    McCoy, Gerald F.
    Wozniak, Andrew P.
    Quinlan, John F.
    [J]. HIP INTERNATIONAL, 2017, 27 (01) : 14 - 20
  • [8] Hip Resurfacing Versus Metal-on-Metal Total Hip Arthroplasty Are Metal Ion Levels Different?
    Kuzyk, Paul R. T.
    Sellan, Michael
    Olsen, Michael
    Schemitsch, Emil H.
    [J]. BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2011, 69 : S5 - S11
  • [9] Differences in concentration of metal debris in blood, serum, and plasma samples of patients with metal-on-metal hip resurfacing arthroplasty
    Khan, M.
    Kuiper, J. H.
    Sieniawska, Christine
    Richardson, J. B.
    [J]. JOURNAL OF ORTHOPAEDICS, 2016, 13 (04) : 450 - 454
  • [10] Surface Characterization of Retrieved Metal-on-Metal Total Hip Implants from Patients with Adverse Reaction to Metal Debris
    Burbano, Maria
    Russell, Robert
    Huo, Michael
    Welch, Robert
    Roy, Diana
    Rodrigues, Danieli C.
    [J]. MATERIALS, 2014, 7 (03): : 1866 - 1879