The sensitivity, specificity and predictive values of raised plasma metal ion levels in the diagnosis of adverse reaction to metal debris in symptomatic patients with a metal-on-metal arthroplasty of the hip

被引:75
|
作者
Malek, I. A. [1 ]
King, A. [1 ]
Sharma, H. [1 ]
Malek, S. [1 ]
Lyons, K. [1 ]
Jones, S. [1 ]
John, A. [1 ]
机构
[1] Univ Wales Hosp, Cardiff CF14 4XW, S Glam, Wales
来源
关键词
RESURFACING ARTHROPLASTY; FOLLOW-UP; REPLACEMENT; COMPONENT; BEARINGS; WEAR; PSEUDOTUMORS; ORIENTATION; IMPLANTS; ARTIFACT;
D O I
10.1302/0301-620X.94B8.27626
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Plasma levels of cobalt and chromium ions and Metal Artefact Reduction Sequence (MARS)-MRI scans were performed on patients with 209 consecutive, unilateral, symptomatic metal-on-metal (MoM) hip arthroplasties. There was wide variation in plasma cobalt and chromium levels, and MARS-MRI scans were positive for adverse reaction to metal debris (ARMD) in 84 hips (40%). There was a significant difference in the median plasma cobalt and chromium levels between those with positive and negative MARS-MRI scans (p < 0.001). Compared with MARS-MRI as the potential reference standard for the diagnosis of ARMD, the sensitivity of metal ion analysis for cobalt or chromium with a cut-off of > 7 mu g/l was 57%. The specificity was 65%, positive predictive value was 52% and the negative predictive value was 69% in symptomatic patients. A lowered threshold of > 3.5 mu g/l for cobalt and chromium ion levels improved the sensitivity and negative predictive value to 86% and 74% but at the expense of specificity (27%) and positive predictive value (44%). Metal ion analysis is not recommended as a sole indirect screening test in the surveillance of symptomatic patients with a MoM arthroplasty. The investigating clinicians should have a low threshold for obtaining cross-sectional imaging in these patients, even in the presence of low plasma metal ion levels.
引用
收藏
页码:1045 / 1050
页数:6
相关论文
共 50 条
  • [31] Serum metal ion levels after second-generation metal-on-metal total hip arthroplasty
    Takao Imanishi
    Masahiro Hasegawa
    Akihiro Sudo
    [J]. Archives of Orthopaedic and Trauma Surgery, 2010, 130 : 1447 - 1450
  • [32] Serum metal ion levels after second-generation metal-on-metal total hip arthroplasty
    Imanishi, Takao
    Hasegawa, Masahiro
    Sudo, Akihiro
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (12) : 1447 - 1450
  • [33] Diagnosis and management of failed metal-on-metal total hip arthroplasty
    Fasmeyer, Jerome
    Lunebourg, Alexandre
    Fischer, Jean-Francois
    Husmann, Olivier
    Vuilleumier, Bertrand
    [J]. SWISS MEDICAL WEEKLY, 2013, 143 : 32S - 32S
  • [34] Adverse Local Tissue Reaction After a Metal-on-Metal Total Hip Prosthesis Without Elevated Serum Metal Ion Levels
    Tetreault, Matthew W.
    Jacobs, Joshua J.
    Mahmud, Waqas
    Nam, Denis
    [J]. ORTHOPEDICS, 2018, 41 (03) : E438 - E441
  • [35] Gene expression in adverse reaction to metal debris around metal-on-metal arthroplasty: An RNA-Seq-based study
    Pemmari, Antti
    Leppanen, Tlina
    Paukkeri, Erja-Leena
    Eskelinen, Antti
    Moilanen, Teemu
    Moilanen, Eeva
    [J]. JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 2018, 48 : 149 - 156
  • [36] Gene expression in adverse reaction to metal debris around metal-on-metal arthroplasty: an RNA-sequencing-based study
    Pemmari, A.
    Leppanen, T.
    Paukkeri, E.
    Eskelinen, A.
    Moilanen, T.
    Moilanen, E.
    [J]. SCANDINAVIAN JOURNAL OF RHEUMATOLOGY, 2018, 47 : 39 - 39
  • [37] Metal-on-Metal Hip Arthroplasty: A Review of Adverse Reactions and Patient Management
    Drummond, James
    Phong Tran
    Fary, Camdon
    [J]. JOURNAL OF FUNCTIONAL BIOMATERIALS, 2015, 6 (03) : 486 - 499
  • [38] GENE EXPRESSION IN ADVERSE REACTION TO METAL DEBRIS AROUND METAL-ON-METAL ARTHROPLASTY: AN RNA-SEQ-BASED STUDY
    Pemmari, A.
    Leppanen, T.
    Moilanen, T.
    Moilanen, E.
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2018, 26 : S130 - S130
  • [39] Adverse effects after metal-on-metal bearings in total hip arthroplasty
    Friesenbichler, J.
    Maurer-Ertl, W.
    Pirker-Fruehauf, U.
    Wolf, M.
    Leithner, A.
    Weger, C.
    Pechmann, M.
    Sadoghi, P.
    [J]. MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2012, 63 (05) : 379 - 385
  • [40] A simulator study of adverse wear with metal and cement debris contamination in metal-on-metal hip bearings
    Halim, T.
    Clarke, I. C.
    Burgett-Moreno, M. D.
    Donaldson, T. K.
    Savisaar, C.
    Bowsher, J. G.
    [J]. BONE & JOINT RESEARCH, 2015, 4 (03): : 29 - 37