Metal ion hypersensitivity in metal-on-metal hip arthroplasty

被引:1
|
作者
Park, Y. -S. [1 ]
Moon, Y. -W. [1 ]
Lim, S. -J. [1 ]
机构
[1] Samsung Med Ctr, Dept Orthoped Surg, 50 Ilwon Dong, Seoul 135710, South Korea
关键词
D O I
10.1007/978-3-7985-1635-9_12
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Total hip arthroplasty with use of metal-on-metal bearings has been reintroduced as an alternative to metal-on-polyethylene bearings because of theoretical advantages such as reduced wear and a lower prevalence of osteolysis. However, we have observed early osteolysis in nine patients (ten hips) out of 165 patients (169 hips) who had been managed with total hip replacements using a contemporary metal-on-metal hip design and investigated the possible etiologic role of metal hypersensitivity. The nine patients who had an osteolytic lesion had a significantly higher prevalence of hypersensitivity to cobalt, as determined by patch testing, when compared to nine controls (p = 0.031). The retrieved periprosthetic tissues from the two revised hips showed no evidence of metallic staining, but microscopic analysis revealed a perivascular accumulation of CID3-positive T-cells and CD68-positive macrophages, and an absence of both particle-laden macrophages and polymorphonuclear cells. Immunohistochemical analysis demonstrated that potent bone-resorbing cytokines such as IL-1 beta and TNF-alpha were produced mainly by infiltrated lymphocytes and activated macrophages. These findings raise the possibility that early osteolysis in this second-generation metal-on-metal hip replacement is associated with abnormalities consistent with delayed-type hypersensitivity to metal.
引用
收藏
页码:57 / +
页数:3
相关论文
共 50 条
  • [1] Metal ion levels in a triathlete with a metal-on-metal resurfacing arthroplasty of the hip
    De Haan, R.
    Campbell, P.
    Reid, S.
    Skipor, A. K.
    De Smet, K.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (04): : 538 - 541
  • [2] Blood metal ion concentrations in metal-on-metal total hip arthroplasty
    Ohtsuru T.
    Morita Y.
    Murata Y.
    Shimamoto S.
    Munakata Y.
    Kato Y.
    [J]. European Journal of Orthopaedic Surgery & Traumatology, 2017, 27 (4) : 527 - 532
  • [3] Metal-on-Metal Total Hip Arthroplasty
    Kim, Raymond H.
    Dennis, Douglas A.
    Carothers, Joshua T.
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (07): : 44 - 46
  • [4] Metal-on-Metal Total Hip Arthroplasty
    Malviya, Ajay
    Ramaskandhan, Jayasree
    Holland, James P.
    Lingard, Elizabeth A.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (07): : 1675 - 1683
  • [5] Metal-on-metal hip resurfacing arthroplasty
    Shimmin, Andrew
    Beaule, Paul E.
    Campbell, Pat
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (03): : 637 - 654
  • [6] Metal Ion Release With Large-Diameter Metal-on-Metal Hip Arthroplasty
    Vendittoli, Pascal-Andre
    Amzica, Traian
    Roy, Alain G.
    Lusignan, Daniel
    Girard, Julien
    Lavigne, Martin
    [J]. JOURNAL OF ARTHROPLASTY, 2011, 26 (02): : 282 - 288
  • [7] Predictive factors for metal ion levels in metal-on-metal total hip arthroplasty
    Maximilian F. Kasparek
    Lisa Renner
    Martin Faschingbauer
    Wenzel Waldstein
    Michael Weber
    Friedrich Boettner
    [J]. Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 281 - 286
  • [8] Predictive factors for metal ion levels in metal-on-metal total hip arthroplasty
    Kasparek, Maximilian F.
    Renner, Lisa
    Faschingbauer, Martin
    Waldstein, Wenzel
    Weber, Michael
    Boettner, Friedrich
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (02) : 281 - 286
  • [9] Hip Resurfacing Versus Metal-on-Metal Total Hip Arthroplasty Are Metal Ion Levels Different?
    Kuzyk, Paul R. T.
    Sellan, Michael
    Olsen, Michael
    Schemitsch, Emil H.
    [J]. BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2011, 69 : S5 - S11
  • [10] Hip resurfacing and metal-on-metal total hip arthroplasty
    Beverland, David E.
    Spencer, Robert F.
    [J]. HIP INTERNATIONAL, 2011, 21 (03) : 277 - 278