Initial fixation strength of two bioabsorbable pins for the fixation of hamstring grafts compared to interference screw fixation -: Single cycle and cyclic loading

被引:58
|
作者
Zantop, T
Weimann, A
Rümmler, M
Hassenpflug, J
Petersen, W
机构
[1] Univ Munster, Dept Trauma Hand & Reconstruct Surg, D-48149 Munster, Germany
[2] Univ Kiel, Dept Orthopaed Surg, Kiel, Germany
来源
AMERICAN JOURNAL OF SPORTS MEDICINE | 2004年 / 32卷 / 03期
关键词
hamstring graft fixation; biomechanics; maximal load; tensile stress; failure mode; cyclic testing;
D O I
10.1177/0095399703258616
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: During the early postoperative period, the fixation of a hamstring graft to the bone tunnel is the primary factor in limiting rehabilitation. Hypothesis: The initial fixation strength of a double cross pin fixation technique is comparable with the biodegradable interference screw fixation technique. Study Design: Experimental laboratory study. Methods: The authors examined the initial fixation strength of two 3.3-mm bioabsorbable pins compared to interference screws for hamstring grafts in bovine knees. Results: Analysis of yield load, maximum load, and stiffness in the single-cycle loading test showed no statistically significant differences for cross pin and interference fixation (P <.05). For cross pins and interference screws, the mean displacement under 1000 cycles to 250 N was 5.07 (+/-1.9) mm and 4.81 (+/-2.5) mm, stiffness 252 (+/-78) N/mm and 289 (+/-148) N/mm. Only grafts fixed with cross pins survived 1000 cycles to 450 N. Conclusion: The initial fixation strength of the double cross pin technique is comparable to that of interference screw fixation with a stiffness comparable to that of the native ACL. Clinical Relevance: Hamstring graft fixation using two cross pins provides an alternative to bioabsorbable interference screw fixation.
引用
收藏
页码:641 / 649
页数:9
相关论文
共 50 条
  • [31] Analysis of initial fixation strength of press-fit fixation technique in anterior cruciate ligament reconstruction - A comparative study with titanium and bioabsorbable interference screw using porcine lower limb
    Lee, MC
    Jo, H
    Bae, TS
    Jang, JD
    Seong, SC
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2003, 11 (02) : 91 - 98
  • [32] Biomechanical Comparison of the Docking Technique With and Without Humeral Bioabsorbable Interference Screw Fixation
    Hurbanek, Jason G.
    Anderson, Kyle
    Crabtree, Stephanie
    Karnes, G. Joshua
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2009, 37 (03): : 526 - 533
  • [33] Arthroscopic biceps tenodesis: A new technique using bioabsorbable interference screw fixation
    Boileau, P
    Krishnan, SG
    Coste, JS
    Walch, G
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (09): : 1002 - 1012
  • [34] Cyclic loading comparison between biodegradable interference screw fixation and biodegradable double cross-pin fixation of human bone-patellar tendon-bone grafts
    Zantop, T
    Ruemmler, M
    Welbers, B
    Langer, M
    Weirnann, A
    Petersen, W
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (08): : 934 - 941
  • [35] Contact pressure on ACL hamstring grafts in the bone tunnel with interference screw fixation - Dynamic adaptation under load
    Meyer, Dominik C.
    Stalder, Michael
    Koch, Peter P.
    Snedeker, Jess G.
    Farshad, Mazda
    KNEE, 2012, 19 (05): : 676 - 679
  • [36] Correlation of bone tunnel diameter with quadrupled hamstring graft fixation strength using a biodegradable interference screw
    Steenlage, E
    Brand, JC
    Johnson, DL
    Caborn, DNM
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (08): : 901 - 907
  • [37] Effect of Interference Screw Depth on Fixation Strength in Biceps Tenodesis
    Salata, Michael J.
    Bailey, James R.
    Bell, Rebecca
    Frank, Rachel M.
    McGill, Kevin C.
    Lin, Emery C.
    Kercher, James S.
    Wang, Vincent M.
    Provencher, Matthew T.
    Mazzocca, Augustus D.
    Verma, Nikhil N.
    Romeo, Anthony A.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2014, 30 (01): : 11 - 15
  • [38] Effect of Interference Screw Fixation on ACL Graft Tensile Strength
    Sawyer, Gregory A.
    Anderson, Brett C.
    Paller, David
    Heard, Wendell Malcolm Rogan
    Fadale, Paul D.
    JOURNAL OF KNEE SURGERY, 2013, 26 (03) : 155 - 159
  • [39] EFFECT OF VARYING ANGLES ON THE PULLOUT STRENGTH OF INTERFERENCE SCREW FIXATION
    JOMHA, NM
    RASO, VJ
    LEUNG, P
    ARTHROSCOPY, 1993, 9 (05): : 580 - 583
  • [40] Comparison of bone-patellar tendon-bone interference screw fixation and hamstring transfemoral screw fixation in anterior cruciate ligament reconstruction
    Randall, RL
    Wolf, EM
    Heilmann, MR
    Lotz, J
    ORTHOPEDICS, 1999, 22 (06) : 587 - 591