Initial fixation strength of two bioabsorbable pins for the fixation of hamstring grafts compared to interference screw fixation -: Single cycle and cyclic loading

被引:58
|
作者
Zantop, T
Weimann, A
Rümmler, M
Hassenpflug, J
Petersen, W
机构
[1] Univ Munster, Dept Trauma Hand & Reconstruct Surg, D-48149 Munster, Germany
[2] Univ Kiel, Dept Orthopaed Surg, Kiel, Germany
来源
AMERICAN JOURNAL OF SPORTS MEDICINE | 2004年 / 32卷 / 03期
关键词
hamstring graft fixation; biomechanics; maximal load; tensile stress; failure mode; cyclic testing;
D O I
10.1177/0095399703258616
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: During the early postoperative period, the fixation of a hamstring graft to the bone tunnel is the primary factor in limiting rehabilitation. Hypothesis: The initial fixation strength of a double cross pin fixation technique is comparable with the biodegradable interference screw fixation technique. Study Design: Experimental laboratory study. Methods: The authors examined the initial fixation strength of two 3.3-mm bioabsorbable pins compared to interference screws for hamstring grafts in bovine knees. Results: Analysis of yield load, maximum load, and stiffness in the single-cycle loading test showed no statistically significant differences for cross pin and interference fixation (P <.05). For cross pins and interference screws, the mean displacement under 1000 cycles to 250 N was 5.07 (+/-1.9) mm and 4.81 (+/-2.5) mm, stiffness 252 (+/-78) N/mm and 289 (+/-148) N/mm. Only grafts fixed with cross pins survived 1000 cycles to 450 N. Conclusion: The initial fixation strength of the double cross pin technique is comparable to that of interference screw fixation with a stiffness comparable to that of the native ACL. Clinical Relevance: Hamstring graft fixation using two cross pins provides an alternative to bioabsorbable interference screw fixation.
引用
收藏
页码:641 / 649
页数:9
相关论文
共 50 条
  • [21] Biomechanical testing of hamstring graft tibial tunnel fixation with bioabsorbable interference screws
    Caborn, DNM
    Nyland, J
    Selby, J
    Tetik, O
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (09): : 991 - 996
  • [22] Dynamic loss of pressure on ACL hamstring grafts - an explanation for poor biomechanical performance with interference screw fixation
    Meyer, D. C.
    Koch, P. P.
    Snedeker, J. G.
    Farshad, M.
    SWISS MEDICAL WEEKLY, 2010, 140 (23-24) : 17S - 17S
  • [23] Initial fixation strength of modified patellar tendon grafts for anatomic fixation in ACL reconstruction
    Peine, R
    Weiler, A
    Bail, H
    Sudkamp, N
    Hoffmann, R
    ARTHROSCOPY, 1998, 14 (04): : 456 - 457
  • [24] Femoral interference screw fixation of hamstring and quadriceps tendons for ACL reconstruction
    M. Ettinger
    T. Werner-Lebeda
    T. Calliess
    M. Omar
    C. Becher
    M. Ezechieli
    M. Klintschar
    M. Petri
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 (4) : 1241 - 1248
  • [25] Femoral interference screw fixation of hamstring and quadriceps tendons for ACL reconstruction
    Ettinger, M.
    Werner-Lebeda, T.
    Calliess, T.
    Omar, M.
    Becher, C.
    Ezechieli, M.
    Klintschar, M.
    Petri, M.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (04) : 1241 - 1248
  • [26] Biosteon Cross Pin Femoral Fixation and Tibial Interference Screw Fixation for Hamstring Anterior Cruciate Ligament Reconstruction
    Stewart, Andrew M.
    Paulos, Lonnie E.
    TECHNIQUES IN ORTHOPAEDICS, 2005, 20 (03) : 254 - 260
  • [27] Cyclic pull-out strength of hamstring tendon graft fixation with soft tissue interference screws - Influence of screw length
    Stadelmaier, DM
    Lowe, WR
    Ilahi, OA
    Noble, PC
    Kohl, HW
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (06): : 778 - 783
  • [28] Arthroscopic ACL reconstruction with reverse "Y"-plasty grafts and fixation in the femur with either a bioabsorbable interference screw or an Endobutton
    Ping, Li Wei
    Bin, Song
    Rui, Yang
    Yang, Song
    Zheng, Zhang Zheng
    Yue, Ding
    KNEE, 2012, 19 (02): : 78 - 83
  • [29] Tendon transfer fixation: Comparing a tendon to tendon technique vs. bioabsorbable interference-fit screw fixation
    Sabonghy, EP
    Wood, RM
    Ambrose, CG
    McGarvey, WC
    Clanton, TO
    FOOT & ANKLE INTERNATIONAL, 2003, 24 (03) : 260 - 262
  • [30] Analysis of initial fixation strength of press-fit fixation technique in anterior cruciate ligament reconstructionA comparative study with titanium and bioabsorbable interference screw using porcine lower limb
    Myung Chul Lee
    Hyunchul Jo
    Tae-Soo Bae
    Jin Dae Jang
    Sang Cheol Seong
    Knee Surgery, Sports Traumatology, Arthroscopy, 2003, 11 : 91 - 98