A Passive Magnetically and Hydrodynamically Suspended Rotary Blood Pump

被引:4
|
作者
Stoiber, Martin [1 ,2 ]
Grasl, Christian [1 ,2 ]
Pirker, Stefan [3 ]
Raderer, Franz [1 ]
Schistek, Roland [4 ]
Huber, Leopold [1 ,2 ]
Gittler, Philipp [3 ]
Schima, Heinrich [1 ,2 ]
机构
[1] Med Univ Vienna, Ctr Biomed Engn & Phys, A-1090 Vienna, Austria
[2] Ludwig Boltzmann Cluster Cardiovasc Res, Vienna, Austria
[3] Johannes Kepler Univ Linz, Inst Fluid Mech & Heat Transfer, A-4040 Linz, Austria
[4] St Johns Hosp, Dept Cardiac Surg, Salzburg, Austria
关键词
Rotary blood pump; Magnetic levitation; Hydrodynamic levitation; Computational fluid dynamics; Blood trauma;
D O I
10.1111/j.1525-1594.2009.00715.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A combined hydrodynamic-magnetic bearing allows the design of rotary blood pumps that are not encumbered with mechanical bearings and magnets requiring sensors or electrical power. However, such pumps have so far needed very small and accurately manufactured gaps between rotor and housing to assure effective hydromagnetic bearing behavior. In order to use this concept in disposable pump heads, a design that allows larger rotor-housing gaps, and thus larger manufacturing tolerances, is needed. A pump with passive magnetic bearings and a gap between rotor and housing in the range of 0.5 mm was designed. Numerical simulations were performed to optimize the rotor geometry at low levels of shear stress. An experimental test stand was used to find a range of speeds and gap settings that resulted in low levels of vibration and useful pressure-flow relationships. Three different rotor geometries were tested using a viscosity-adjusted test fluid. Blood damage tests were conducted within the desirable range of speeds and gap settings. In this study stable pump performance was demonstrated at total gap widths between 0.3 and 0.7 mm at flows of 0-10 L/min, with afterloads up to 230 mm Hg. Best performance was achieved with rotors sliding on a fluid pillow between the rotor and the outer housing at a gap distance of 50 to 250 mu m. The inner gap distance, between the rotor and the inner housing, could be as great as 500 mu m. Hemolysis tests on the prototype within the chosen operating range showed lower values (NIH = 0.0029 +/- 0.0012 g/100 L) than the Biomedicus BP-80 pump (NIH = 0.0033 +/- 0.0011 g/100 L). In conclusion, it is possible to build rotary blood pumps with passive hydromagnetic bearings that have large gaps between their rotors and housings. Rotor behavior is sensitive to the position of the permanent magnetic drive unit. To minimize vibration and blood damage, the fluid gaps and the rotational speed have to be adjusted according to the desired operating point of the pump. Further study is needed to optimize the magnetic drive unit and to ascertain its ability to withstand inertial loads imposed by sudden movements and external shock.
引用
收藏
页码:250 / 257
页数:8
相关论文
共 50 条
  • [11] Performance and unsteady characteristics of magnetically suspended centrifugal blood pump
    Yoshino, Y
    Akamatsu, T
    JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 1997, 40 (01) : 114 - 120
  • [12] Magnetically suspended centrifugal blood pump with a radial magnetic driver
    Hoshi, H
    Katakoa, K
    Ohuchi, K
    Asama, J
    Shinshi, T
    Shimokohbe, A
    Takatani, S
    ASAIO JOURNAL, 2005, 51 (01) : 60 - 64
  • [13] A Novel Design of Spiral Groove Bearing in a Hydrodynamically Levitated Centrifugal Rotary Blood Pump
    Han, Qing
    Zou, Jun
    Ruan, Xiaodong
    Fu, Xin
    Yang, Huayong
    ARTIFICIAL ORGANS, 2012, 36 (08) : 739 - 746
  • [14] Sensorless Viscosity Measurement in a Magnetically-Levitated Rotary Blood Pump
    Hijikata, Wataru
    Rao, Jun
    Abe, Shodai
    Takatani, Setsuo
    Shinshi, Tadahiko
    ARTIFICIAL ORGANS, 2015, 39 (07) : 559 - 568
  • [15] Visualization of main and leakage flow in magnetically suspended centrifugal blood pump
    Masaaki Horie
    Keiichi Yamamura
    Journal of Visualization, 2012, 15 : 353 - 361
  • [16] DEVELOPMENT OF MAGNETICALLY SUSPENDED VANELESS CENTRIFUGAL BLOOD PUMP FOR CARDIOPULMONARY BYPASS
    Lee, Y.
    Chang, J. K.
    Lee, S. H.
    Jang, J. U.
    Lee, K. B.
    Lee, H. W.
    Sun, K.
    Kim, H. M.
    Kim, J.
    Yoo, J. Y.
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2003, 3 (02) : 187 - 196
  • [17] Visualization of main and leakage flow in magnetically suspended centrifugal blood pump
    Horie, Masaaki
    Yamamura, Keiichi
    JOURNAL OF VISUALIZATION, 2012, 15 (04) : 353 - 361
  • [18] Numerical investigation on hydrodynamics and biocompatibility of a magnetically suspended axial blood pump
    Zhu, Xianran
    Zhang, Mingyuan
    Zhang, Genguang
    Liu, Haonan
    ASAIO JOURNAL, 2006, 52 (06) : 624 - 629
  • [19] Mechanical electronic model for magnetically suspended left ventricular axial blood pump
    College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
    不详
    Huazhong Ligong Daxue Xuebao, 2007, 2 (110-112):
  • [20] The Effects of Ambulatory Accelerations on the Stability of a Magnetically Suspended Impeller for an Implantable Blood Pump
    Paul, Gordon
    Rezaienia, Mohammed Amin
    Rahideh, Akbar
    Munjiza, Ante
    Korakianitis, Theodosios
    ARTIFICIAL ORGANS, 2016, 40 (09) : 867 - 876