Visualization of main and leakage flow in magnetically suspended centrifugal blood pump

被引:2
|
作者
Horie, Masaaki [1 ]
Yamamura, Keiichi [2 ]
机构
[1] Setsunan Univ, Dept Mech Engn, Neyagawa, Osaka 5728508, Japan
[2] Setsunan Univ, Grad Sch Engn, Neyagawa, Osaka 5728508, Japan
关键词
Centrifugal pump; Artificial heart; Specific speed; Leakage flow; Dove prism;
D O I
10.1007/s12650-012-0137-y
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Magnetically suspended centrifugal blood pump is implantable blood pump that can obtain an enough blood pressure and blood flow to assist the adult left ventricle. This blood pump has an impeller without a shaft in order to avoid thrombus formation on the shaft seal. It is important to improve the efficiency of this artificial heart pump and to develop a pump with a low-machine Reynolds number and a low-specific speed. In this study, we carried out a visualization experiment with a rotating Dove prism and concluded with a numerical analysis, focusing on the main flow and leakage flow. It was found that the main flow pattern inside the impeller was different between all vanes, and the leakage flow in the gap was non-uniform.
引用
下载
收藏
页码:353 / 361
页数:9
相关论文
共 50 条
  • [1] Visualization of main and leakage flow in magnetically suspended centrifugal blood pump
    Masaaki Horie
    Keiichi Yamamura
    Journal of Visualization, 2012, 15 : 353 - 361
  • [2] CENTRIFUGAL BLOOD PUMP WITH A MAGNETICALLY SUSPENDED IMPELLER
    AKAMATSU, T
    NAKAZEKI, T
    ITOH, H
    ARTIFICIAL ORGANS, 1992, 16 (03) : 305 - 308
  • [3] A magnetically suspended and hydrostatically stabilized centrifugal blood pump
    Hart, RM
    Filipenco, VG
    Kung, RTV
    ARTIFICIAL ORGANS, 1996, 20 (06) : 591 - 596
  • [4] Use of motor current in flow rate measurement for the magnetically suspended centrifugal blood pump
    Tsukiya, T
    Akamatsu, T
    Nishimura, K
    Yamada, T
    Nakazeki, T
    ARTIFICIAL ORGANS, 1997, 21 (05) : 396 - 401
  • [5] RECENT STUDIES OF THE CENTRIFUGAL BLOOD PUMP WITH A MAGNETICALLY SUSPENDED IMPELLER
    AKAMATSU, T
    TSUKIYA, T
    NISHIMURA, K
    PARK, CH
    NAKAZEKI, T
    ARTIFICIAL ORGANS, 1995, 19 (07) : 631 - 634
  • [6] Performance and unsteady characteristics of magnetically suspended centrifugal blood pump
    Yoshino, Y
    Akamatsu, T
    JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 1997, 40 (01) : 114 - 120
  • [7] Magnetically suspended centrifugal blood pump with a self bearing motor
    Masuzawa, T
    Onuma, H
    Kim, SJ
    Okada, Y
    ASAIO JOURNAL, 2002, 48 (04) : 437 - 442
  • [8] Magnetically suspended centrifugal blood pump with an axially levitated motor
    Masuzawa, T
    Ezoe, S
    Kato, T
    Okada, Y
    ARTIFICIAL ORGANS, 2003, 27 (07) : 631 - 638
  • [9] Magnetically suspended centrifugal blood pump with a radial magnetic driver
    Hoshi, H
    Katakoa, K
    Ohuchi, K
    Asama, J
    Shinshi, T
    Shimokohbe, A
    Takatani, S
    ASAIO JOURNAL, 2005, 51 (01) : 60 - 64
  • [10] Flow visualization studies in a centrifugal blood pump
    Ng, B.T.H.
    Chan, W.K.
    Yu, S.C.M.
    Chua, L.P.
    American Society of Mechanical Engineers, Bioengineering Division (Publication) BED, 1999, 42 : 163 - 164