Carotid artery flow as determined by real-time phase-contrast flow MRI and neurovascular ultrasound: A comparative study of healthy subjects

被引:9
|
作者
Maier, Ilko L. [1 ]
Hofer, Sabine [2 ]
Joseph, Arun A. [2 ,3 ]
Merboldt, K. Dietmar [2 ]
Tan, Zhengguo [2 ]
Schregel, Katharina [4 ,5 ]
Knauth, Michael [4 ]
Baehr, Mathias [1 ]
Psychogios, Marios-Nikos [4 ]
Liman, Jan [1 ]
Frahm, Jens [2 ,3 ]
机构
[1] Univ Med Ctr Gottingen, Dept Neurol, Robert Koch Str 40, D-37075 Gottingen, Germany
[2] Max Planck Inst Biophys Chem, Biomed NMR Forsch GmbH, Gottingen, Germany
[3] German Ctr Cardiovasc Res DZHK, Partner Site Gottingen, Gottingen, Germany
[4] Univ Med Ctr Gottingen, Dept Neuroradiol, Gottingen, Germany
[5] Harvard Med Sch, Brigham & Womens Hosp, Dept Radiol, Boston, MA USA
关键词
Carotid artery; Doppler sonography; Duplex sonography; Neurovascular ultrasound; Real-time flow MRI; Velocity profiles; QUANTIFICATION; RECONSTRUCTION; HEMODYNAMICS; BIFURCATION; POPULATION; RESOLUTION; VESSELS; MODEL;
D O I
10.1016/j.ejrad.2018.07.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The assessment of carotid artery flow by neurovascular ultrasound (nvUS) can be complemented by real-time phase-contrast (RT-PC) flow MRI which apart from quantitative flow parameters offers velocity distributions across the entire vessel lumen. Materials and methods: The feasibility and diagnostic potential of RT-PC flow MRI was evaluated in 20 healthy volunteers in comparison to conventional nvUS. RT-PC flow MRI at 40 ms temporal resolution and 0.8 mm in-plane resolution resulted in velocity maps with low phase noise and high spatiotemporal accuracy by exploiting respective advances of a recent nonlinear inverse model-based reconstruction. Peak-systolic velocities (PSV), end-diastolic velocities (EDV), flow volumes and comprehensive velocity profiles were determined in the common, internal and external carotid artery on both sides. Results: Flow characteristics such as pulsatility and individual abnormalities shown on nvUS could be reproduced and visualized in detail by RT-PC flow MRI. PSV to EDV differences revealed good agreement between both techniques, mean PSV and EDV were significantly lower and flow volumes were higher for MRI. Conclusion: Our findings suggest that RT-PC flow MRI adds to clinical diagnostics, e.g. by alterations of dynamic velocity distributions in patients with carotid stenosis. Lower PSV and EDV values than for nvUS mainly reflect the longer MRI acquisition time which attenuates short peak velocities, while higher flow volumes benefit from a proper assessment of the true vessel lumen.
引用
收藏
页码:38 / 45
页数:8
相关论文
共 50 条
  • [1] Carotid Artery Flow as Determined by Real-Time Phase-Contrast Flow Mri and Neurovascular Ultrasound: a Comparative Study of Healthy Subjects
    Maier, Ilko
    Hofer, Sabine
    Joseph, Arun A.
    Merboldt, Klaus-Dietmar
    Tan, Zhengguo
    Schregel, Katharina
    Knauth, Michael
    Bahr, Mathias
    Psychogios, Marios-Nikos
    Liman, Jan
    Frahm, Jens
    [J]. STROKE, 2018, 49
  • [2] Spatiotemporal Phase Unwrapping for Real-Time Phase-Contrast Flow MRI
    Untenberger, Markus
    Huellebrand, Markus
    Tautz, Lennart
    Joseph, Arun A.
    Voit, Dirk
    Merboldt, K. Dietmar
    Frahm, Jens
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (04) : 964 - 970
  • [3] 4D REAL-TIME PHASE-CONTRAST FLOW MRI WITH SPARSE SAMPLING
    Sun, Aiqi
    Zhao, Bo
    Li, Rui
    Yuan, Chun
    [J]. 2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 3252 - 3255
  • [4] Advances in Real-Time Phase-Contrast Flow MRI Using Asymmetric Radial Gradient Echoes
    Untenberger, Markus
    Tan, Zhengguo
    Voit, Dirk
    Joseph, Arun A.
    Roeloffs, Volkert
    Merboldt, K. Dietmar
    Schaetz, Sebastian
    Frahm, Jens
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (05) : 1901 - 1908
  • [5] Blood Flow of Ophthalmic Artery in Healthy Individuals Determined by Phase-Contrast Magnetic Resonance Imaging
    Ambarki, Khalid
    Hallberg, Per
    Johannesson, Gauti
    Linden, Christina
    Zarrinkoob, Laleh
    Wahlin, Anders
    Birgander, Richard
    Malm, Jan
    Eklund, Anders
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (04) : 2738 - 2745
  • [6] CSF and venous blood flow from childhood to adulthood studied by real-time phase-contrast MRI
    Prativa Sahoo
    Jost M. Kollmeier
    Nora Wenkel
    Simon Badura
    Jutta Gärtner
    Jens Frahm
    Steffi Dreha-Kulaczewski
    [J]. Child's Nervous System, 2024, 40 : 1377 - 1388
  • [7] Model-Based Reconstruction for Real-Time Phase-Contrast Flow MRI: Improved Spatiotemporal Accuracy
    Tan, Zhengguo
    Roeloffs, Volkert
    Voit, Dirk
    Joseph, Arun A.
    Untenberger, Markus
    Merboldt, K. Dietmar
    Frahm, Jens
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (03) : 1082 - 1093
  • [8] CSF and venous blood flow from childhood to adulthood studied by real-time phase-contrast MRI
    Sahoo, Prativa
    Kollmeier, Jost M.
    Wenkel, Nora
    Badura, Simon
    Gaertner, Jutta
    Frahm, Jens
    Dreha-Kulaczewski, Steffi
    [J]. CHILDS NERVOUS SYSTEM, 2024, 40 (05) : 1377 - 1388
  • [9] Real-time measurement of renal blood flow in healthy subjects using contrast-enhanced ultrasound
    Kalantarinia, Kambiz
    Belcik, J. Todd
    Patrie, James T.
    Wei, Kevin
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-RENAL PHYSIOLOGY, 2009, 297 (04) : F1129 - F1134
  • [10] The Effects of Free Breathing on Cerebral Venous Flow: A Real-Time Phase Contrast MRI Study in Healthy Adults
    Liu, Pan
    Monnier, Heimiri
    Owashi, Kimi
    Constans, Jean -Marc
    Capel, Cyrille
    Baledent, Olivier
    [J]. JOURNAL OF NEUROSCIENCE, 2024, 44 (03):