Detection of colorectal polyps: Comparison of multi-detector row CT and MR colonography in a colon phantom

被引:14
|
作者
Wessling, Johannes
Fischbach, Roman
Borchert, Alexandra
Kugel, Harald
Allkemper, Thomas
Osada, Nani
Heindel, Walter
机构
[1] Univ Munster, Dept Clin Radiol, D-48149 Munster, Germany
[2] Univ Munster, Dept Med Informat & Biomath, D-48149 Munster, Germany
关键词
D O I
10.1148/radiol.2411050292
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare multi-detector row (four- and 16-section) computed tomography (CT), including a low-dose protocol, with high-field-strength (1.5- and 3.0-T) magnetic resonance (MR) imaging for reader detection of colorectal polyps in a colon phantom. Materials and Methods: A colon phantom with simulated haustral folds and 10 polyps of varying size (2.0 - 8.0 mm) was imaged at four-and 16-section CT (section thicknesses of 1.25 and 0.75 mm, reconstruction increments of 0.8 and 0.7 mm, and 100 and 10 mAs, respectively, and 120 kV for both) and at 1.5- and 3.0-T MR imaging (three-dimensional gradient-recalled echo sequence, section thickness of 1.4 mm). Three-dimensional endoluminal images were assessed by 10 reviewers for each modality regarding polyp detection. Comparisons of sensitivities were performed by using logistic regression. Results: Overall, polyps were detected with a sensitivity of 87% (95% confidence interval [CI]: 80%, 94%) at four- section CT, 92% (95% CI: 87%, 97%) at 16-section CT, 56% (95% CI: 46%, 66%) at 1.5- T MR imaging, and 55% (95% CI: 45%, 65%) at 3.0-T MR imaging. The detection of polyps at least 4 mm in diameter was not influenced by the modality or radiation dose (sensitivity of 100%). CT performed in low-dose mode depicted all polyps with a diameter of at least 3 mm. Polyps smaller than 3 mm in diameter were detected with a sensitivity of 7.5% ( 1.5- T MR imaging), 22.5% (3.0-T MR imaging), and 20% (low-dose CT); detection rates were significantly greater (P < .001) with normal-dose CT (four section, 67.5%; 16 section, 82.5%). Increased spatial resolution (with CT) and higher field strength (with MR imaging) had no significant effect on polyp detection. Conclusion: With both multi - detector row CT and MR imaging, readers detected polyps above the clinically relevant threshold diameter of 6 mm, with similar sensitivities.
引用
收藏
页码:125 / 131
页数:7
相关论文
共 50 条
  • [11] CT colography (virtual colonoscopy) with multi-detector array CT: Scan for detection of colorectal polyps
    Gluecker, TM
    Jornod, P
    Keller, W
    Blum, AG
    Meuli, RA
    Dorta, G
    RADIOLOGY, 2000, 217 : 369 - 369
  • [12] Benefits of contrast-enhanced multi-detector row CT colonography for preoperative staging in colorectal cancer patients
    Iinuma, G
    Moriyama, N
    Satake, M
    Miyakawa, K
    Muramatsu, Y
    Tateishi, U
    Akasu, T
    Otake, Y
    Fujii, T
    Kobayashi, T
    MEDICAL IMAGING 2003: PHYSIOLOGY AND FUNCTION: METHODS, SYSTEMS, AND APPLICATIONS, 2003, 5031 : 398 - 404
  • [13] Colorectal polyps:: Detection with multi-slice CT colonography
    Wessling, J
    Fischbach, R
    Domagk, D
    Lügering, N
    Neumann, E
    Heindel, W
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (12): : 1069 - 1071
  • [14] Multi-detector row CT of hemoptysis
    Bruzzi, John F.
    Remy-Jardin, Martine
    Delhaye, Damien
    Teisseire, Antoine
    Khalil, Chadi
    Remy, Jacques
    RADIOGRAPHICS, 2006, 26 (01) : 3 - U78
  • [15] Interosseous ligament tears of the wrist: Comparison of multi-detector row CT arthrography and MR imaging
    Schmid, MR
    Schertler, T
    Pfirrmann, CW
    Saupe, N
    Manestar, M
    Wildermuth, S
    Welshaupt, D
    RADIOLOGY, 2005, 237 (03) : 1008 - 1013
  • [16] Multi-detector row CT colonography: Effect of collimation, pitch, and orientation on polyp detection in a human colectomy specimen
    Taylor, SA
    Halligan, S
    Bartram, CI
    Morgan, PR
    Talbot, IC
    Fry, N
    Saunders, BP
    Khosraviani, K
    Atkin, W
    RADIOLOGY, 2003, 229 (01) : 109 - 118
  • [17] CT colonography for detection of colon polyps and cancer
    Ferrucci, J
    LANCET, 2005, 365 (9469): : 1464 - 1465
  • [18] Multi-detector row spiral CT pulmonary angiography: Comparison with single-detector row spiral CT
    Raptopoulos, V
    Boiselle, PM
    RADIOLOGY, 2001, 221 (03) : 606 - 613
  • [19] CT: status on multi-detector row scanners
    Martinez-Souloumiac, L.
    Gosso, F.
    JOURNAL DE RADIOLOGIE, 2006, 87 (7-8): : 927 - 935
  • [20] Automated detection of ureter abnormalities on multi-detector row CT urography
    Hadjiiski, Lubomir
    Sahiner, Berkman
    Caoili, Elaine M.
    Cohan, Richard H.
    Chan, Heang-Ping
    MEDICAL IMAGING 2006: IMAGE PROCESSING, PTS 1-3, 2006, 6144