Detection of colorectal polyps: Comparison of multi-detector row CT and MR colonography in a colon phantom

被引:14
|
作者
Wessling, Johannes
Fischbach, Roman
Borchert, Alexandra
Kugel, Harald
Allkemper, Thomas
Osada, Nani
Heindel, Walter
机构
[1] Univ Munster, Dept Clin Radiol, D-48149 Munster, Germany
[2] Univ Munster, Dept Med Informat & Biomath, D-48149 Munster, Germany
关键词
D O I
10.1148/radiol.2411050292
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare multi-detector row (four- and 16-section) computed tomography (CT), including a low-dose protocol, with high-field-strength (1.5- and 3.0-T) magnetic resonance (MR) imaging for reader detection of colorectal polyps in a colon phantom. Materials and Methods: A colon phantom with simulated haustral folds and 10 polyps of varying size (2.0 - 8.0 mm) was imaged at four-and 16-section CT (section thicknesses of 1.25 and 0.75 mm, reconstruction increments of 0.8 and 0.7 mm, and 100 and 10 mAs, respectively, and 120 kV for both) and at 1.5- and 3.0-T MR imaging (three-dimensional gradient-recalled echo sequence, section thickness of 1.4 mm). Three-dimensional endoluminal images were assessed by 10 reviewers for each modality regarding polyp detection. Comparisons of sensitivities were performed by using logistic regression. Results: Overall, polyps were detected with a sensitivity of 87% (95% confidence interval [CI]: 80%, 94%) at four- section CT, 92% (95% CI: 87%, 97%) at 16-section CT, 56% (95% CI: 46%, 66%) at 1.5- T MR imaging, and 55% (95% CI: 45%, 65%) at 3.0-T MR imaging. The detection of polyps at least 4 mm in diameter was not influenced by the modality or radiation dose (sensitivity of 100%). CT performed in low-dose mode depicted all polyps with a diameter of at least 3 mm. Polyps smaller than 3 mm in diameter were detected with a sensitivity of 7.5% ( 1.5- T MR imaging), 22.5% (3.0-T MR imaging), and 20% (low-dose CT); detection rates were significantly greater (P < .001) with normal-dose CT (four section, 67.5%; 16 section, 82.5%). Increased spatial resolution (with CT) and higher field strength (with MR imaging) had no significant effect on polyp detection. Conclusion: With both multi - detector row CT and MR imaging, readers detected polyps above the clinically relevant threshold diameter of 6 mm, with similar sensitivities.
引用
收藏
页码:125 / 131
页数:7
相关论文
共 50 条
  • [41] Pitfalls in multi detector row CT colonography: A systematic approach
    Mang, Thomas
    Maier, Andrea
    Plank, Christina
    Mueller-Mang, Christina
    Herold, Christian
    Schima, Wolfgang
    RADIOGRAPHICS, 2007, 27 (02) : 431 - 454
  • [42] Optimizing colonic distention for multi-detector row CT colonography: Effect of hyoscine butylbromide and rectal balloon catheter
    Taylor, SA
    Halligan, S
    Goh, V
    Morley, S
    Bassett, P
    Atkin, W
    Bartram, CI
    RADIOLOGY, 2003, 229 (01) : 99 - 108
  • [43] Hepatic metastases: Detection with multi-detector row CT, SPIO-enhanced MR imaging, and both techniques combined
    Onishi, H
    Murakami, T
    Kim, T
    Hori, M
    Iannaccone, R
    Kuwabara, M
    Abe, H
    Nakata, S
    Osuga, K
    Tomoda, K
    Passariello, R
    Nakamura, H
    RADIOLOGY, 2006, 239 (01) : 131 - 138
  • [44] False-negative results at multi-detector row CT colonography: Multivariate analysis of causes for missed lesions
    Park, SH
    Ha, HK
    Kim, MJ
    Kim, KW
    Kim, AY
    Yang, DH
    Lee, MG
    Kim, PN
    Shin, YM
    Yang, SK
    Myung, SJ
    Min, YI
    RADIOLOGY, 2005, 235 (02) : 495 - 502
  • [45] Cardiac functional analysis with multi-detector row CT and segmental reconstruction algorithm: Comparison with echocardiography, SPECT, and MR imaging
    Yamamuro, M
    Tadamura, E
    Kubo, S
    Toyoda, H
    Nishina, T
    Ohba, M
    Hosokawa, R
    Kimura, T
    Tamaki, N
    Komeda, M
    Kita, T
    Konishi, J
    RADIOLOGY, 2005, 234 (02) : 381 - 390
  • [46] CT colonography for detection of colon polyps and cancer - Authors' reply
    Rockey, DC
    Paulson, E
    Rubin, DT
    Halvorsen, R
    Thompson, WM
    Dachman, A
    Niedzwicki, D
    LANCET, 2005, 365 (9469): : 1465 - 1466
  • [47] Cardiac valve assessment with MR imaging and 64-section multi-detector row CT
    Vogel-Claussen, Jens
    Pannu, Harpreet
    Spevak, Philip J.
    Fishman, Elliot K.
    Bluemke, David A.
    RADIOGRAPHICS, 2006, 26 (06) : 1769 - 1784
  • [48] Detection of flat colorectal polyps at screening CT colonography in comparison with conventional polypoid lesions
    Sakamoto, Takashi
    Mitsuzaki, Katsuhiko
    Utsunomiya, Daisuke
    Matsuda, Katsuhiko
    Yamamura, Sadahiro
    Urata, Joji
    Kawakami, Megumi
    Yamashita, Yasuyuki
    ACTA RADIOLOGICA, 2012, 53 (07) : 714 - 719
  • [49] Pulmonary nodules on multi-detector row CT scans: Performance comparison of radiologists and computer-aided detection
    Rubin, GD
    Lyo, JK
    Paik, DS
    Sherbondy, AJ
    Chow, LC
    Leung, AN
    Mindelzun, R
    Schraedley-Desmond, PK
    Zinck, SE
    Naidich, DP
    Napel, S
    RADIOLOGY, 2005, 234 (01) : 274 - 283
  • [50] Detection of colorectal lesions: Lower-dose multi-detector row helical CT colonograph compared with conventional colonoscopy
    Iannaccone, R
    Laghi, A
    Catalano, C
    Brink, JA
    Mangiapane, F
    Trenna, S
    Piacentini, F
    Passariello, R
    RADIOLOGY, 2003, 229 (03) : 775 - 781