Quantification of the 3D relative movement of external marker sets vs. bones based on magnetic resonance imaging

被引:48
|
作者
Sangeux, M.
Marin, F.
Charleux, F.
Duerselen, L.
Tho, M. C. Ho Ba [1 ]
机构
[1] UTC, CNRS, UMR6600, Lab Biomecan & Genie Biomed, Compiegne, France
[2] Univ Hosp Ulm, Inst Orthopaed Res & Biomech, Ulm, Germany
[3] Polyclin St Come, CIMA, Compiegne, France
关键词
knee joint; kinematics; MRI; external markers; three-dimensional;
D O I
10.1016/j.clinbiomech.2006.05.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. Most in vivo knee kinematic analyses are based on external markers attached to the shank and the thigh. Literature data show that markers positioning and soft tissues artifacts affect the kinematic parameters of the bones true movement. Most of the techniques of quantification used were invasive. The aim of the present study was to develop and apply a non-invasive methodology to compute the relative movement between the bones and the markers. Methods. Magnetic resonance imaging acquisitions were performed on the right knee of eleven volunteers without knee injury. The subjects were equipped with external magnetic resonance imaging-compatible marker sets. A foot drive device allowed the subjects to perform an actively loaded knee extension. The whole volume of the subject's knee was processed for four sequentially held knee flexion positions during the knee movement. The bones and external marker sets geometry were reconstructed from magnetic resonance imaging images. Then a registration algorithm was applied to the bones and the relative movement of the thigh and shank marker sets with respect to their underlying bones was computed. Findings. The protocol resulted in a good geometrical accuracy and reproducibility. Marker sets movement differ from that of the bones with a maximum of 22 mm in translation and 15 degrees in rotation and it affects the knee kinematics. Interpretation. Marker sets relative movement modify the knee movement finite helical axes direction (range 10-35 degrees) and localization (range 0-40 mm). The methodology developed can evaluate external marker set system to be used for kinematic analysis in a clinical environment. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:984 / 991
页数:8
相关论文
共 50 条
  • [21] 3D quantification visualization of vascular structures in magnetic resonance angiographic images
    Schaap, JA
    de Koning, PJH
    Janssen, JP
    Westenberg, JJM
    van der Geest, RJ
    Reiber, JHC
    COMPUTATIONAL SCIENCE-ICCS 2002, PT III, PROCEEDINGS, 2002, 2331 : 242 - 254
  • [22] 3D Quantitative-Amplified Magnetic Resonance Imaging (3D q-aMRI)
    Terem, Itamar
    Younes, Kyan
    Wang, Nan
    Condron, Paul
    Abderezaei, Javid
    Kumar, Haribalan
    Vossler, Hillary
    Kwon, Eryn
    Kurt, Mehmet
    Mormino, Elizabeth
    Holdsworth, Samantha
    Setsompop, Kawin
    BIOENGINEERING-BASEL, 2024, 11 (08):
  • [23] Automated segmentation of 3D cine cardiovascular magnetic resonance imaging
    Arasteh, Soroosh Tayebi
    Romanowicz, Jennifer
    Pace, Danielle F.
    Golland, Polina
    Powell, Andrew J.
    Maier, Andreas K.
    Truhn, Daniel
    Brosch, Tom
    Weese, Juergen
    Lotfinia, Mahshad
    Van der Geest, Rob J.
    Moghari, Mehdi H.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [24] SNR Analysis of 3D Magnetic Resonance Tomosynthesis (MRT) Imaging
    Kim, Min-Oh
    Kim, Dong-Hyun
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [25] 3D imaging using magnetic resonance tomosynthesis (MRT) technique
    Kim, Min-Oh
    Zho, Sang-Young
    Kim, Dong-Hyun
    MEDICAL PHYSICS, 2012, 39 (08) : 4733 - 4741
  • [26] 3D Plastronics for Smartly Integrated Magnetic Resonance Imaging Coils
    Gerges, Tony
    Semet, Vincent
    Lombard, Philippe
    Gaillard, Sophie
    Cabrera, Michel
    Lambert, Simon Auguste
    FRONTIERS IN PHYSICS, 2020, 8
  • [27] PULSATILE FLOW ARTIFACTS IN 3D MAGNETIC-RESONANCE-IMAGING
    FRANK, LR
    BUXTON, RB
    KERBER, CW
    MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (03) : 296 - 304
  • [28] Applications of 3D printing in small animal magnetic resonance imaging
    Nouls, John C.
    Virgincar, Rohan S.
    Culbert, Alexander G.
    Morand, Nathann
    Bobbert, Dana W.
    Yoder, Anne D.
    Schopler, Robert S.
    Bashir, Mustafa R.
    Badea, Alexandra
    Hochgeschwender, Ute
    Driehuys, Bastiaan
    JOURNAL OF MEDICAL IMAGING, 2019, 6 (02)
  • [29] 3D Texton Based Prostate Cancer Detection Using Multiparametric Magnetic Resonance Imaging
    Wang, Liping
    Zwiggelaar, Reyer
    MEDICAL IMAGE UNDERSTANDING AND ANALYSIS (MIUA 2017), 2017, 723 : 309 - 319
  • [30] A parametric intensity-based 3D image registration method for magnetic resonance imaging
    Song, Huajun
    Qiu, Peihua
    SIGNAL IMAGE AND VIDEO PROCESSING, 2017, 11 (03) : 455 - 462