Quantification of the 3D relative movement of external marker sets vs. bones based on magnetic resonance imaging

被引:48
|
作者
Sangeux, M.
Marin, F.
Charleux, F.
Duerselen, L.
Tho, M. C. Ho Ba [1 ]
机构
[1] UTC, CNRS, UMR6600, Lab Biomecan & Genie Biomed, Compiegne, France
[2] Univ Hosp Ulm, Inst Orthopaed Res & Biomech, Ulm, Germany
[3] Polyclin St Come, CIMA, Compiegne, France
关键词
knee joint; kinematics; MRI; external markers; three-dimensional;
D O I
10.1016/j.clinbiomech.2006.05.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. Most in vivo knee kinematic analyses are based on external markers attached to the shank and the thigh. Literature data show that markers positioning and soft tissues artifacts affect the kinematic parameters of the bones true movement. Most of the techniques of quantification used were invasive. The aim of the present study was to develop and apply a non-invasive methodology to compute the relative movement between the bones and the markers. Methods. Magnetic resonance imaging acquisitions were performed on the right knee of eleven volunteers without knee injury. The subjects were equipped with external magnetic resonance imaging-compatible marker sets. A foot drive device allowed the subjects to perform an actively loaded knee extension. The whole volume of the subject's knee was processed for four sequentially held knee flexion positions during the knee movement. The bones and external marker sets geometry were reconstructed from magnetic resonance imaging images. Then a registration algorithm was applied to the bones and the relative movement of the thigh and shank marker sets with respect to their underlying bones was computed. Findings. The protocol resulted in a good geometrical accuracy and reproducibility. Marker sets movement differ from that of the bones with a maximum of 22 mm in translation and 15 degrees in rotation and it affects the knee kinematics. Interpretation. Marker sets relative movement modify the knee movement finite helical axes direction (range 10-35 degrees) and localization (range 0-40 mm). The methodology developed can evaluate external marker set system to be used for kinematic analysis in a clinical environment. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:984 / 991
页数:8
相关论文
共 50 条
  • [11] The value of 3D magnetic resonance imaging in the planning of neurosurgery
    Hoell, T
    Oltmanns, F
    Schilling, A
    Schernick, A
    Brock, M
    CONTROVERSIES IN NEURO-ONCOLOGY, 1999, 33 : 88 - 93
  • [12] Magnetic Resonance Imaging of An in Vitro 3D Tumor Model
    Veiga, C.
    Long, T.
    Siow, B.
    Loizidou, M.
    Royle, G.
    Ricketts, K.
    MEDICAL PHYSICS, 2015, 42 (06) : 3579 - 3579
  • [13] Modelling of the 3D geometry in the human rectum based on magnetic resonance imaging (MRI)
    Frokjaer, JB
    McMahon, BP
    Liao, DH
    Drewes, AM
    Gregersen, H
    GASTROENTEROLOGY, 2004, 126 (04) : A202 - A203
  • [14] Fiducial-based fusion of 3D dental models with magnetic resonance imaging
    Abdi, Amir H.
    Hannam, Alan G.
    Fels, Sidney
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2018, 13 (07) : 1109 - 1115
  • [15] Fiducial-based fusion of 3D dental models with magnetic resonance imaging
    Amir H. Abdi
    Alan G. Hannam
    Sidney Fels
    International Journal of Computer Assisted Radiology and Surgery, 2018, 13 : 1109 - 1115
  • [16] Direct comparison of 3D spiral vs. Cartesian gradient-echo coronary magnetic resonance angiography
    Börnert, P
    Stuber, M
    Botnar, RM
    Kissinger, KV
    Koken, P
    Spuentrup, E
    Manning, WJ
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (04) : 789 - 794
  • [17] High-resolution 3D magnetic resonance imaging and quantification of carious lesions and dental pulp in vivo
    Tymofiyeva, Olga
    Boldt, Julian
    Rottner, Kurt
    Schmid, Florian
    Richter, Ernst-Juergen
    Jakob, Peter M.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2009, 22 (06) : 365 - 374
  • [18] 3D magnetic resonance cholangiopancreatography (MRCP) and magnetic resonance imaging (MRI) for evaluation of cholangiocarcinoma
    Vanderveen, K
    Hussain, H
    Weadock, WJ
    Adusumilli, S
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (04) : 90 - 90
  • [19] High-resolution 3D magnetic resonance imaging and quantification of carious lesions and dental pulp in vivo
    Olga Tymofiyeva
    Julian Boldt
    Kurt Rottner
    Florian Schmid
    Ernst-Juergen Richter
    Peter M. Jakob
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2009, 22 : 365 - 374
  • [20] A 3D Quantification Technique for Liver Fat Fraction Distribution Analysis Using Dixon Magnetic Resonance Imaging
    Zhao, Fan
    Zhang, Genming
    Tan, Zhongjian
    Liang, Tengxiao
    Xing, Fangliang
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (200):