PULSATILE FLOW ARTIFACTS IN 3D MAGNETIC-RESONANCE-IMAGING

被引:13
|
作者
FRANK, LR
BUXTON, RB
KERBER, CW
机构
[1] Department of Radiology, University of California at San Diego, San Diego, California
关键词
PULSATILE FLOW ARTIFACTS; MAGNETIC RESONANCE ANGIOGRAPHY; VOLUME IMAGING;
D O I
10.1002/mrm.1910300305
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Some of the important features of how pulsatile flow generates artifacts in three-dimensional magnetic resonance imaging are analyzed and demonstrated. Time variations in the magnetic resonance signal during the heart cycle lead to more complex patterns of artifacts in 3D imaging than in 2D imaging. The appearance and location of these artifacts within the image volume are shown to be describable as displacements along a line in a plane parallel to that defined by the phase and volume encode directions. The angle of the line in the plane depends solely upon the imaging parameters while the ghost displacement along the line is proportional to the signal modulation frequency. Aliasing of these ghosts leads to a variety of artifact patterns which are sensitive to the pulsation period and repetition time of the pulse sequence. Numerical simulations of these effects were found to be in good agreement with experimental images of an elastic model of a human carotid artery under simulated physiological conditions and with images of two human subjects.
引用
收藏
页码:296 / 304
页数:9
相关论文
共 50 条
  • [1] ELIMINATION OF OBLIQUE FLOW ARTIFACTS IN MAGNETIC-RESONANCE-IMAGING
    FRANK, LR
    CRAWLEY, AP
    BUXTON, RB
    MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) : 299 - 307
  • [2] ARTIFACTS IN MAGNETIC-RESONANCE-IMAGING
    HENKELMAN, RM
    BRONSKILL, MJ
    MEDICAL PHYSICS, 1987, 14 (03) : 506 - 507
  • [3] TRUNCATION ARTIFACTS IN MAGNETIC-RESONANCE-IMAGING
    WOOD, ML
    HENKELMAN, RM
    MAGNETIC RESONANCE IN MEDICINE, 1985, 2 (06) : 517 - 526
  • [4] POSTOPERATIVE MAGNETIC-RESONANCE-IMAGING ARTIFACTS - REPORT OF 3 CASES
    FIRSCHING, RP
    HEINDEL, W
    ERNESTUS, RI
    FROWEIN, RA
    BUNKE, J
    JOURNAL OF NEUROSURGERY, 1987, 67 (05) : 776 - 778
  • [5] METALLIC SPINAL ARTIFACTS IN MAGNETIC-RESONANCE-IMAGING
    VACCARO, AR
    CHESNUT, RM
    SCUDERI, G
    HEALY, JF
    MASSIE, JB
    GARFIN, SR
    SPINE, 1994, 19 (11) : 1237 - 1242
  • [6] TATTOOING OF EYELIDS - MAGNETIC-RESONANCE-IMAGING ARTIFACTS
    LUND, G
    NELSON, JD
    WIRTSCHAFTER, JD
    WILLIAMS, PA
    OPHTHALMIC SURGERY AND LASERS, 1986, 17 (09): : 550 - 553
  • [7] FAST 3D CHEMICAL-SHIFT MAGNETIC-RESONANCE-IMAGING
    VINITSKI, S
    SZUMOWSKI, J
    RAO, VM
    BURK, DL
    MITCHELL, DG
    ORTEGA, H
    RIFKIN, MD
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 517 - 519
  • [8] MAGNETIC-RESONANCE-IMAGING FLOW
    BEST, JJK
    BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (717): : 944 - 944
  • [9] MAGNETIC-RESONANCE-IMAGING ARTIFACTS INDUCED BY OCULAR PROSTHESIS
    FRY, CL
    HAIK, BG
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1994, 118 (02) : 262 - 263
  • [10] SUPPRESSION OF RESPIRATORY MOTION ARTIFACTS IN MAGNETIC-RESONANCE-IMAGING
    WOOD, ML
    HENKELMAN, RM
    MEDICAL PHYSICS, 1986, 13 (06) : 794 - 805