PULSATILE FLOW ARTIFACTS IN 3D MAGNETIC-RESONANCE-IMAGING

被引:13
|
作者
FRANK, LR
BUXTON, RB
KERBER, CW
机构
[1] Department of Radiology, University of California at San Diego, San Diego, California
关键词
PULSATILE FLOW ARTIFACTS; MAGNETIC RESONANCE ANGIOGRAPHY; VOLUME IMAGING;
D O I
10.1002/mrm.1910300305
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Some of the important features of how pulsatile flow generates artifacts in three-dimensional magnetic resonance imaging are analyzed and demonstrated. Time variations in the magnetic resonance signal during the heart cycle lead to more complex patterns of artifacts in 3D imaging than in 2D imaging. The appearance and location of these artifacts within the image volume are shown to be describable as displacements along a line in a plane parallel to that defined by the phase and volume encode directions. The angle of the line in the plane depends solely upon the imaging parameters while the ghost displacement along the line is proportional to the signal modulation frequency. Aliasing of these ghosts leads to a variety of artifact patterns which are sensitive to the pulsation period and repetition time of the pulse sequence. Numerical simulations of these effects were found to be in good agreement with experimental images of an elastic model of a human carotid artery under simulated physiological conditions and with images of two human subjects.
引用
收藏
页码:296 / 304
页数:9
相关论文
共 50 条
  • [41] MAGNETIC-RESONANCE-IMAGING AND MEASUREMENT OF BLOOD-FLOW
    MCDONNELL, CH
    HERFKENS, RJ
    NORBASH, AM
    RUBIN, GD
    WESTERN JOURNAL OF MEDICINE, 1994, 160 (03): : 237 - 242
  • [42] DISTORTIONS FROM CURVED FLOW IN MAGNETIC-RESONANCE-IMAGING
    FRANK, LR
    BUXTON, RB
    MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (01) : 84 - 93
  • [43] MAGNETIC-RESONANCE-IMAGING OF FLOW DYNAMICS IN THE CIRCLE OF WILLIS
    EDELMAN, RR
    MATTLE, HP
    OREILLY, GV
    WENTZ, KU
    LIU, C
    ZHAO, B
    STROKE, 1990, 21 (01) : 56 - 65
  • [44] IN-VIVO COMPARISON OF 3D ULTRASONOGRAPHY AND MAGNETIC-RESONANCE-IMAGING IN VOLUME ESTIMATION OF HUMAN KIDNEYS
    GILJA, OH
    SMIEVOLL, AI
    THUNE, N
    MATRE, K
    HAUSKEN, T
    ODEGAARD, S
    BERSTAD, A
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (01): : 25 - 32
  • [45] CURVILINEAR RECONSTRUCTION OF 3D MAGNETIC-RESONANCE-IMAGING IN PATIENTS WITH PARTIAL EPILEPSY - A PILOT-STUDY
    BASTOS, AC
    KORAH, IP
    CENDES, F
    MELANSON, D
    TAMPIERI, D
    PETERS, T
    DUBEAU, F
    ANDERMANN, F
    MAGNETIC RESONANCE IMAGING, 1995, 13 (08) : 1107 - 1112
  • [46] ARTIFACTS FROM PULSATILE FLOW IN MR IMAGING
    PERMAN, WH
    MORAN, PR
    MORAN, RA
    BERNSTEIN, MA
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (03) : 473 - 483
  • [47] MAGNETIC RESONANCE ADVECTION IMAGING (MRAI): SENSITIVITY TO PULSATILE FLOW
    Voss, H. U.
    Dyke, J. P.
    Tabelow, K.
    Ballon, D. J.
    Schiff, N. D.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2016, 36 : 85 - 86
  • [48] Routine 3D Magnetic Resonance Imaging of Joints
    Kijowski, Richard
    Gold, Garry E.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (04) : 758 - 771
  • [49] Artifacts in Magnetic Resonance Imaging
    Krupa, Katarzyna
    Bekiesinska-Figatowska, Monika
    POLISH JOURNAL OF RADIOLOGY, 2015, 80 : 93 - 106
  • [50] DIAGNOSTIC-VALUE OF MAGNETIC-RESONANCE-IMAGING (MRI) IN THE DIAGNOSTIC MANAGEMENT OF PULSATILE TINNITUS
    ARNOLD, B
    JAGER, L
    GREVERS, G
    LARYNGO-RHINO-OTOLOGIE, 1995, 74 (03) : 179 - 182