Improved efficacy of anodal biphasic defibrillation shocks following a failed defibrillation attempt

被引:1
|
作者
Roberts, PR
Allen, S
Smith, DC
Urban, JF
Euler, DE
Kallok, MJ
Morgan, JM
机构
[1] Southampton Gen Hosp, Wessex Cardiothorac Ctr, Southampton SO9 4XY, Hants, England
[2] Angeion Corp, Minneapolis, MN USA
来源
关键词
ventricular defibrillation; polarity; biphasic; duration; fibrillation;
D O I
10.1111/j.1540-8159.1999.tb00407.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although it is generally assumed that defibrillation becomes more difficult when the duration of VF is prolonged, after a failed defibrillation attempt, there is little information on the defibrillation efficacy of multiple shocks delivered at the same energy. The purpose of this study was to systematically examine the efficacy of a second shock delivered at the same or reversed polarity after a failed first shock. Defibrillation was attempted after I a seconds of VF in 12 pigs (30-56 kg) using biphasic waveforms and a nonthoracotomy lead system. Shock energy was held constant for the first and second shocks art 50%-90% of the DFT. The second shock was delivered 10 seconds after a failed first shock. First and second shock polarity (first phase) was randomized to (+, +), (+, -), (-, -), (-, +). The incidence of successful defibrillation (for all polarities) was 12.3% for first and 49.1% for second shocks (P < 0.0001). Anodal first shocks had a 17.2% incidence of success as opposed to a 7.4% incidence of success with cathodal first shocks (P = 0.001). Anodal second shocks had a 55.5% incidence of success compared to a 42.7% incidence of success with cathodal second shocks (P = 0.008). There was no significant benefit from polarity reversal after a failed first shock (P = 0.29). In conclusion, less energy is required for successful defibrillation by a second shock after a failed first. The optimal configuration for first and second shocks is with the RV as anode. Polarity reversal of a second shock after a failed first does not affect the probability of second shock success.
引用
收藏
页码:1753 / 1759
页数:7
相关论文
共 50 条
  • [1] NON-THORACOTOMY INTERNAL DEFIBRILLATION - IMPROVED EFFICACY WITH BIPHASIC SHOCKS
    CHAPMAN, PD
    WETHERBEE, JN
    VETTER, JW
    TROUP, PJ
    CIRCULATION, 1987, 76 (04) : 312 - 312
  • [2] NON-THORACOTOMY INTERNAL DEFIBRILLATION - IMPROVED EFFICACY WITH BIPHASIC SHOCKS
    CHAPMAN, PD
    WETHERBEE, JN
    VETTER, JW
    TROUP, PJ
    CLINICAL RESEARCH, 1987, 35 (06): : A829 - A829
  • [3] IMPROVED INTERNAL DEFIBRILLATION EFFICACY WITH A BIPHASIC WAVEFORM
    FAIN, ES
    SWEENEY, MB
    FRANZ, MR
    AMERICAN HEART JOURNAL, 1989, 117 (02) : 358 - 364
  • [4] Prospective randomized comparison of anodal monophasic shocks versus biphasic cathodal shocks on defibrillation energy requirements
    Strickberger, SA
    Daoud, E
    Goyal, R
    Chan, KK
    Bogun, F
    Castellani, M
    Harvey, M
    Horwood, LE
    Niebauer, M
    Man, KC
    Morady, F
    AMERICAN HEART JOURNAL, 1996, 131 (05) : 961 - 965
  • [5] SIMULTANEOUS BIPHASIC SHOCKS ENHANCE EFFICACY OF ENDOCARDIAL CARDIOVERSION DEFIBRILLATION IN MAN
    SAKSENA, S
    AN, H
    KROL, RB
    BURKHARDT, E
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (11): : 1935 - 1942
  • [6] Effects of polarity for monophasic and biphasic shocks on defibrillation efficacy with an endocardial system
    Usui, M
    Walcott, GP
    Strickberger, SA
    Rollins, DL
    Smith, WM
    Ideker, RE
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (01): : 65 - 71
  • [7] Effect of coupling interval in failed defibrillation with long postshock responses using monophasic and biphasic shocks
    Tovar, OH
    Jones, JL
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 372A - 372A
  • [8] EFFECT OF FAILED DEFIBRILLATION SHOCKS ON ELECTROGRAM AMPLITUDE IN A NONINTEGRATED TRANSVENOUS DEFIBRILLATION LEAD SYSTEM
    BRADY, PA
    FRIEDMAN, PA
    STANTON, MS
    AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (08): : 580 - 584
  • [9] A comparison of biphasic and monophasic shocks for external defibrillation of humans
    Herre, JM
    Higgins, SL
    Epstein, AE
    Greer, S
    Friedman, PL
    Gleva, MJ
    Porterfield, JG
    Chapman, FW
    Finkel, ES
    Schmitt, PW
    Nova, RC
    Greene, HL
    CIRCULATION, 1998, 98 (17) : 173 - 173
  • [10] IMPROVED DEFIBRILLATION EFFICACY WITH CHRONICALLY IMPLANTED DEFIBRILLATION LEADS
    MEAD, RH
    RUDER, M
    SCHMIDT, P
    GAUDIANI, V
    WINKLE, R
    CIRCULATION, 1986, 74 (04) : 110 - 110