Improved efficacy of anodal biphasic defibrillation shocks following a failed defibrillation attempt

被引:1
|
作者
Roberts, PR
Allen, S
Smith, DC
Urban, JF
Euler, DE
Kallok, MJ
Morgan, JM
机构
[1] Southampton Gen Hosp, Wessex Cardiothorac Ctr, Southampton SO9 4XY, Hants, England
[2] Angeion Corp, Minneapolis, MN USA
来源
关键词
ventricular defibrillation; polarity; biphasic; duration; fibrillation;
D O I
10.1111/j.1540-8159.1999.tb00407.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although it is generally assumed that defibrillation becomes more difficult when the duration of VF is prolonged, after a failed defibrillation attempt, there is little information on the defibrillation efficacy of multiple shocks delivered at the same energy. The purpose of this study was to systematically examine the efficacy of a second shock delivered at the same or reversed polarity after a failed first shock. Defibrillation was attempted after I a seconds of VF in 12 pigs (30-56 kg) using biphasic waveforms and a nonthoracotomy lead system. Shock energy was held constant for the first and second shocks art 50%-90% of the DFT. The second shock was delivered 10 seconds after a failed first shock. First and second shock polarity (first phase) was randomized to (+, +), (+, -), (-, -), (-, +). The incidence of successful defibrillation (for all polarities) was 12.3% for first and 49.1% for second shocks (P < 0.0001). Anodal first shocks had a 17.2% incidence of success as opposed to a 7.4% incidence of success with cathodal first shocks (P = 0.001). Anodal second shocks had a 55.5% incidence of success compared to a 42.7% incidence of success with cathodal second shocks (P = 0.008). There was no significant benefit from polarity reversal after a failed first shock (P = 0.29). In conclusion, less energy is required for successful defibrillation by a second shock after a failed first. The optimal configuration for first and second shocks is with the RV as anode. Polarity reversal of a second shock after a failed first does not affect the probability of second shock success.
引用
收藏
页码:1753 / 1759
页数:7
相关论文
共 50 条
  • [41] Improved defibrillation efficacy with a triad defibrillation system using a 90 uF capacitor
    Bahu, M
    Knight, BP
    Weiss, R
    Paladino, W
    Hahn, S
    Goyal, R
    Daoud, EG
    Harvey, M
    Man, KC
    Morady, F
    Stickberger, SA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 83127 - 83127
  • [42] Right Ventricular Insertions Play an Important Role in the Reinitiation of Ventricular Fibrillation Following Failed Defibrillation Shocks
    Iijima, Kenichi
    Zhang, Hanyu
    Huang, Jian
    Walcott, Gregory P.
    Rogers, Jack M.
    CIRCULATION, 2017, 136
  • [43] Characteristics of earliest activation following failed atrial defibrillation
    Zheng, XS
    Huang, J
    Ideker, RE
    CIRCULATION, 2002, 106 (19) : 180 - 180
  • [44] Comparison of single-biphasic versus sequential-biphasic shocks on defibrillation threshold in pigs
    Csanadi, Z
    Jones, DL
    Wood, GK
    Klein, GJ
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (06): : 1606 - 1612
  • [45] IMPROVED LOW-ENERGY DEFIBRILLATION EFFICACY IN MAN WITH THE USE OF A BIPHASIC TRUNCATED EXPONENTIAL WAVEFORM
    WINKLE, RA
    MEAD, RH
    RUDER, MA
    GAUDIANI, V
    BUCH, WS
    PLESS, B
    SWEENEY, M
    SCHMIDT, P
    AMERICAN HEART JOURNAL, 1989, 117 (01) : 122 - 127
  • [46] Biphasic and monophasic shocks for transthoracic defibrillation: a meta analysis of randomised controlled trials
    Faddy, SC
    Powell, J
    Craig, JC
    RESUSCITATION, 2003, 58 (01) : 9 - 16
  • [47] EFFECTIVE DEFIBRILLATION IN PIGS USING INTERLEAVED AND COMMON PHASE SEQUENTIAL BIPHASIC SHOCKS
    GUSE, PA
    ROLLINS, DL
    KRASSOWSKA, W
    WOLF, PD
    SMITH, WM
    IDEKER, RE
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (08): : 1719 - 1734
  • [48] Reversing the initial phase polarity of biphasic shocks: Is the effect on the defibrillation threshold reproducible?
    Narasimhan, C
    Sra, J
    Deshpande, S
    Keelan, ET
    Dhala, A
    Panotopoulos, PT
    CIRCULATION, 1996, 94 (08) : 2561 - 2561
  • [49] FACTORS WHICH MAY EXPLAIN DIFFERENT DEFIBRILLATION THRESHOLDS FOR MONOPHASIC AND BIPHASIC SHOCKS
    DILLON, SM
    WANG, T
    BIOPHYSICAL JOURNAL, 1993, 64 (02) : A206 - A206
  • [50] Effect of second phase duration on biphasic defibrillation efficacy in humans
    Merkely, B
    Lubiñski, A
    Gyöngy, T
    Lewicka-Nowak, E
    Horkay, F
    Swiatecka, G
    Gellér, L
    Bodor, E
    Pilz, J
    Schaldach, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 373A - 373A