Improved efficacy of anodal biphasic defibrillation shocks following a failed defibrillation attempt

被引:1
|
作者
Roberts, PR
Allen, S
Smith, DC
Urban, JF
Euler, DE
Kallok, MJ
Morgan, JM
机构
[1] Southampton Gen Hosp, Wessex Cardiothorac Ctr, Southampton SO9 4XY, Hants, England
[2] Angeion Corp, Minneapolis, MN USA
来源
关键词
ventricular defibrillation; polarity; biphasic; duration; fibrillation;
D O I
10.1111/j.1540-8159.1999.tb00407.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although it is generally assumed that defibrillation becomes more difficult when the duration of VF is prolonged, after a failed defibrillation attempt, there is little information on the defibrillation efficacy of multiple shocks delivered at the same energy. The purpose of this study was to systematically examine the efficacy of a second shock delivered at the same or reversed polarity after a failed first shock. Defibrillation was attempted after I a seconds of VF in 12 pigs (30-56 kg) using biphasic waveforms and a nonthoracotomy lead system. Shock energy was held constant for the first and second shocks art 50%-90% of the DFT. The second shock was delivered 10 seconds after a failed first shock. First and second shock polarity (first phase) was randomized to (+, +), (+, -), (-, -), (-, +). The incidence of successful defibrillation (for all polarities) was 12.3% for first and 49.1% for second shocks (P < 0.0001). Anodal first shocks had a 17.2% incidence of success as opposed to a 7.4% incidence of success with cathodal first shocks (P = 0.001). Anodal second shocks had a 55.5% incidence of success compared to a 42.7% incidence of success with cathodal second shocks (P = 0.008). There was no significant benefit from polarity reversal after a failed first shock (P = 0.29). In conclusion, less energy is required for successful defibrillation by a second shock after a failed first. The optimal configuration for first and second shocks is with the RV as anode. Polarity reversal of a second shock after a failed first does not affect the probability of second shock success.
引用
收藏
页码:1753 / 1759
页数:7
相关论文
共 50 条
  • [31] A framework of current based defibrillation improves defibrillation efficacy of biphasic truncated exponential waveform in rabbits
    Li, Weiming
    Li, Jingru
    Wei, Liang
    Wang, Jianjie
    Peng, Li
    Wang, Juan
    Yin, Changlin
    Li, Yongqin
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [32] A DIRECT COMPARISON OF EPICARDIAL AND NONTHORACOTOMY DEFIBRILLATION USING MONOPHASIC AND BIPHASIC SHOCKS
    THAKUR, RK
    SOUZA, JJ
    TROUP, PJ
    CHAPMAN, PD
    WETHERBEE, JN
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (01): : 70 - 74
  • [33] A framework of current based defibrillation improves defibrillation efficacy of biphasic truncated exponential waveform in rabbits
    Weiming Li
    Jingru Li
    Liang Wei
    Jianjie Wang
    Li Peng
    Juan Wang
    Changlin Yin
    Yongqin Li
    Scientific Reports, 11
  • [34] SUPERIORITY OF BIPHASIC SHOCKS IN THE DEFIBRILLATION OF DOGS BY EPICARDIAL PATCHES AND CATHETER ELECTRODES
    FLAKER, GC
    SCHUDER, JC
    MCDANIEL, WC
    STOECKLE, H
    DBEIS, M
    AMERICAN HEART JOURNAL, 1989, 118 (02) : 288 - 291
  • [35] Relative efficacy of different tilts with biphasic defibrillation in humans
    Natale, A
    Sra, J
    Krum, D
    Dhala, A
    Deshpande, S
    Jazayeri, M
    Newby, K
    Wase, A
    Axtell, K
    VanHout, WL
    Akhtar, M
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (02): : 197 - 206
  • [36] Improved defibrillation efficacy with triphasic waveforms
    Huang, J
    Kenknight, BH
    Smith, WM
    Ideker, RE
    CIRCULATION, 1997, 96 (08) : 3243 - 3243
  • [37] Internal atrial defibrillation in humans - Improved efficacy of biphasic waveforms and the importance of phase duration
    Cooper, RAS
    Johnson, EE
    Wharton, JM
    CIRCULATION, 1997, 95 (06) : 1487 - 1496
  • [38] Polarity reversal improves defibrillation efficacy in patients undergoing transvenous cardioverter defibrillator implantation with biphasic shocks
    Schauerte, P
    Stellbrink, C
    Schondube, FA
    Loser, H
    Haltern, G
    Messmer, BJ
    Hanrath, P
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (02): : 301 - 306
  • [39] CLINICAL EFFICACY AND SAFETY OF ATRIAL DEFIBRILLATION USING BIPHASIC SHOCKS AND CURRENT NONTHORACOTOMY ENDOCARDIAL LEAD CONFIGURATIONS
    SAKSENA, S
    PRAKASH, A
    MANGEON, L
    VARANASI, S
    KOLETTIS, T
    MATHEW, P
    DEGROOT, P
    MEHRA, R
    KROL, RB
    AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (12): : 913 - 921
  • [40] FIBRILLATION RECURRENCE SITES FOLLOWING FAILED NONTHORACOTOMY DEFIBRILLATION
    KAVANAGH, KM
    TANG, ASL
    SIMPSON, EV
    MELNICK, SB
    SMITH, WM
    IDEKER, RE
    CIRCULATION, 1990, 82 (04) : 182 - 182