Integrated and automatic mixing of whole blood: An evaluation of a novel blood gas analyzer

被引:17
|
作者
Grenache, David G.
Parker, Christopher
机构
[1] Univ N Carolina, Sch Med, Dept Pathol & Lab Med, Chapel Hill, NC 27599 USA
[2] Univ N Carolina Hosp, McLendon Clin Labs, Chapel Hill, NC 27514 USA
关键词
blood gases; electrolytes; hemoglobin; preanalytical error; sample mixing;
D O I
10.1016/j.cca.2006.07.002
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: A homogeneous whole blood specimen is essential to produce quality results from blood gas analysis, however achieving an adequately mixed specimen can be difficult due to the absence of any dead space in a blood gas syringe. This study evaluated the efficacy of an automatic mixing feature incorporated into the ABL800 FLEX blood gas analyzer and estimated the systematic error in tests performed by the instrument. Methods: Quantitative measurements of pH, PCO2, PO2, Na+, K+, Ca+, glucose, lactate, and total hemoglobin were performed on 388 whole blood specimens collected into standard blood gas syringes or specific syringes designed to work in conjunction with the ABL800 FLEX. One hundred eighty specimens were manually or automatically mixed following horizontal storage for 10, 20, or 30 min and total hemoglobin was used as in indicator of specimen homogeneity. Two hundred eight specimens were used to estimate the systematic error of tests performed by the ABL800 FLEX. Results: Manual mixing produced significantly more variation in paired hemoglobin measurements compared to automatic mixing at all three time points (p < 0.0001). All estimates of systematic error were very low and clinically insignificant. Quantitative results showed excellent agreement with a reference analyzer. Conclusions: In contrast to manual mixing, automatic mixing by the ABL800 FLEX consistently produces a homogeneous specimen. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:153 / 157
页数:5
相关论文
共 50 条
  • [41] CascadionTM SM Clinical Analyzer: Evaluation of the whole blood immunosuppressants quantification and routine usability
    Mathieu, Elise
    Duterme, Cecile
    Fage, David
    Cotton, Frederic
    CLINICA CHIMICA ACTA, 2023, 539 : 97 - 104
  • [42] EVALUATION OF 9 METHODS ON THE AVL OMNI(TM) WHOLE-BLOOD CHEMISTRY ANALYZER
    BODOR, GS
    GOSATIDWELL, F
    DURHAM, BJ
    ASLDRICH, T
    BENGE, H
    CLINICAL CHEMISTRY, 1995, 41 (06) : S174 - S174
  • [43] Analytical performance assessment of a novel cartridge-based blood gas analyzer
    Cervera, Jose
    Mansouri, Sohrab
    Pamidi, Prasad V. A.
    CLINICAL BIOCHEMISTRY, 2019, 63 : 154 - 155
  • [44] Clinical evaluation of the Chiron Rapidpoint™ 400 whole blood chemistry blood gas system.
    Polito, FA
    DeHavens, A
    Yeo, KT
    CLINICAL CHEMISTRY, 1999, 45 (06) : A132 - A132
  • [45] Evaluation of the whole blood creatinine assay on the radiometer ABL837 blood gas analyser
    Naidoo, D.
    Day, P. J.
    Moshides, J. S.
    CLINICAL CHEMISTRY, 2007, 53 (06) : A219 - A219
  • [46] Novel In-Line Hemolysis Detection on a Blood Gas Analyzer for Capillary Samples
    Adib, L.
    Butler, M.
    McNary, N.
    Balasubramanian, S.
    Pamidi, P.
    CLINICAL CHEMISTRY, 2024, 70 : I130 - I130
  • [47] Evaluation of blood cell count using an automatic hematology analyzer to optimize collection of peripheral blood progenitor cells by leukapheresis
    Pederzoli, Paula Renata Machado Passos
    Prata, Karen de Lima
    Cruz, Nathalia Gomide
    Marzano, Pedro Victorio de Almeida
    Martins, Mauricio Colombini
    Costa, Luciana de Almeida
    de Andrade, Roberta Kelly
    Libanio, Marcia Regina Issa Salomao
    Custer, Brian
    Belisario, Andre Rolim
    HEMATOLOGY TRANSFUSION AND CELL THERAPY, 2024, 46 : S150 - S156
  • [48] A PORTABLE BLOOD-GAS ANALYZER FOR EQUINE VENOUS-BLOOD
    MITTEN, LA
    HINCHCLIFF, KW
    SAMS, R
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 1995, 9 (05) : 353 - 356
  • [49] Accuracy of a portable blood gas analyzer incorporating optodes for canine blood
    Shiroshita, Y
    Tanaka, R
    Shibazaki, A
    Yamane, Y
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 1999, 13 (06) : 597 - 600
  • [50] Accuracy and Reliability of Whole Blood Bilirubin Measurements Using a Roche Blood Gas Analyzer for Neonatal Hyperbilirubinemia Screening and Risk Stratification
    Wang, Qing
    Zhang, Tianyi
    Lin, Yuanxi
    Jiang, Li
    Zhou, Wenlong
    Zong, Xiaolong
    FRONTIERS IN PEDIATRICS, 2022, 10