Integrated and automatic mixing of whole blood: An evaluation of a novel blood gas analyzer

被引:17
|
作者
Grenache, David G.
Parker, Christopher
机构
[1] Univ N Carolina, Sch Med, Dept Pathol & Lab Med, Chapel Hill, NC 27599 USA
[2] Univ N Carolina Hosp, McLendon Clin Labs, Chapel Hill, NC 27514 USA
关键词
blood gases; electrolytes; hemoglobin; preanalytical error; sample mixing;
D O I
10.1016/j.cca.2006.07.002
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: A homogeneous whole blood specimen is essential to produce quality results from blood gas analysis, however achieving an adequately mixed specimen can be difficult due to the absence of any dead space in a blood gas syringe. This study evaluated the efficacy of an automatic mixing feature incorporated into the ABL800 FLEX blood gas analyzer and estimated the systematic error in tests performed by the instrument. Methods: Quantitative measurements of pH, PCO2, PO2, Na+, K+, Ca+, glucose, lactate, and total hemoglobin were performed on 388 whole blood specimens collected into standard blood gas syringes or specific syringes designed to work in conjunction with the ABL800 FLEX. One hundred eighty specimens were manually or automatically mixed following horizontal storage for 10, 20, or 30 min and total hemoglobin was used as in indicator of specimen homogeneity. Two hundred eight specimens were used to estimate the systematic error of tests performed by the ABL800 FLEX. Results: Manual mixing produced significantly more variation in paired hemoglobin measurements compared to automatic mixing at all three time points (p < 0.0001). All estimates of systematic error were very low and clinically insignificant. Quantitative results showed excellent agreement with a reference analyzer. Conclusions: In contrast to manual mixing, automatic mixing by the ABL800 FLEX consistently produces a homogeneous specimen. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:153 / 157
页数:5
相关论文
共 50 条
  • [31] EXERCISES WITH A BLOOD-GAS ANALYZER
    BUCHANAN, N
    EYBERG, C
    SOUTH AFRICAN MEDICAL JOURNAL, 1973, 47 (38): : 1757 - 1759
  • [32] Creatinine assay in blood gas analyzer
    Ferreira, C. E.
    Faulhaber, A. C.
    Pasternak, J.
    Lourenco, L. M.
    Mangueira, C. L.
    CLINICAL CHEMISTRY, 2009, 55 (06) : A212 - A212
  • [33] Evaluation of neonatal bilirubin method on RapidLab 500 blood gas analyzer
    Vranken, L.
    Pieltain, C.
    Cavalier, E.
    ACTA CLINICA BELGICA, 2017, 72 : 8 - 8
  • [34] EVALUATION OF CIBA CORNING MODEL 280 BLOOD-GAS ANALYZER
    SCHLEBUSCH, H
    HARNACK, H
    CLINICAL CHEMISTRY, 1990, 36 (06) : 1191 - 1191
  • [35] EVALUATION OF AN AUTOMATIC PLATELET COUNTING SYSTEM UTILIZING WHOLE-BLOOD
    ROWAN, RM
    ALLAN, W
    PRESCOTT, RJ
    JOURNAL OF CLINICAL PATHOLOGY, 1972, 25 (03) : 218 - &
  • [36] AUTOMATIC DETERMINATION OF GALACTOSE IN WHOLE BLOOD
    HARDING, U
    ZEITSCHRIFT FUR KLINISCHE CHEMIE UND KLINISCHE BIOCHEMIE, 1970, 8 (05): : 541 - &
  • [37] Evaluation of an automated blood bank analyzer
    Taylor, L
    TRANSFUSION, 1998, 38 (10) : 121S - 121S
  • [38] EVALUATION OF AMES BLOOD ANALYZER SYSTEM
    ZAIDMAN, JL
    SEGAL, S
    ISRAEL JOURNAL OF MEDICAL SCIENCES, 1977, 13 (04): : 450 - 450
  • [39] EVALUATION OF AN AUTOMATED BLOOD SMEAR ANALYZER
    SCHOENTAG, RA
    PEDERSEN, JT
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1979, 71 (06) : 685 - 694
  • [40] EVALUATION OF THE RAPID CBC AND CRP ANALYZER USING SMALL AMOUNT OF WHOLE BLOOD SAMPLE
    Pastore, Manuela
    Chabert, Cecile
    Nomura, Noyuki
    Ikeda, Motohide
    Saito, Kensuke
    Sakai, Ai
    Kono, Eriko
    Tanaka, Hidema
    Ikemoto, Toshiyuki
    Takubo, Takayuki
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2012, 34 : 126 - 127