Detection of c-reactive protein based on a magnetic immunoassay by using functional magnetic and fluorescent nanoparticles in microplates

被引:27
|
作者
Yang, S. F. [1 ]
Gao, B. Z. [1 ]
Tsai, H. Y. [2 ,3 ]
Fuh, C. Bor [1 ]
机构
[1] Natl Chi Nan Univ, Dept Appl Chem, Puli 545, Nantou, Taiwan
[2] Chung Shan Med Univ, Dept Appl Chem, Taichung 402, Taiwan
[3] Chung Shan Med Univ Hosp, Clin Lab, Taichung 402, Taiwan
关键词
NANOCRYSTALS;
D O I
10.1039/c4an00921e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report the preparation and application of biofunctional nanoparticles to detect C-reactive protein (CRP) in magnetic microplates. A CRP model biomarker was used to test the proposed detection method. Biofunctional magnetic nanoparticles, CRP, and biofunctional fluorescent nanoparticles were used in a sandwich nanoparticle immunoassay. The CRP concentrations in the samples were deduced from the reference plot, using the fluorescence intensity of the sandwich nanoparticle immunoassay. When biofunctional nanoparticles were used to detect CRP, the detection limit was 1.0 ng ml(-1) and the linear range was between 1.18 ng ml(-1) and 11.8 mu g ml(-1). The results revealed that the method involving biofunctional nanoparticles exhibited a lower detection limit and a wider linear range than those of the enzyme-linked immunosorbent assay (ELISA) and most other methods. For CRP measurements of serum samples, the differences between this method and ELISA in CRP measurements of serum samples were less than 13%. The proposed method can reduce the analysis time to one-third that of ELISA. This method demonstrates the potential to replace ELISA for rapidly detecting biomarkers with a low detection limit and a wide dynamic range.
引用
收藏
页码:5576 / 5581
页数:6
相关论文
共 50 条
  • [31] Evaluation of an enzyme immunoassay for the high sensitive detection of c-reactive protein (CRP).
    Kaufmann, J
    Heide, K
    Claeys, G
    Bossuyt, X
    CLINICAL CHEMISTRY, 2001, 47 (06) : A42 - A42
  • [32] MAGNETIC IMMUNOASSAY - A HETEROGENEOUS IMMUNOASSAY BASED ON THE DETECTION OF MAGNETIC PARTICLES
    GRUETZMACHER, RR
    EBERSOLE, RC
    WANG, LT
    FORSYTHE, JG
    KERR, RJ
    GELORMINI, FT
    DALESSANDRO, T
    REGESTER, DJ
    CLINICAL CHEMISTRY, 1983, 29 (06) : 1252 - 1252
  • [33] An aptasensor based on the microscopic enumeration of encoding gold nanoparticles for the detection of C-reactive protein
    Zhao, Yuanfang
    Zhao, Jingru
    Jin, Tian
    Sun, Shuqing
    Liu, Wenlan
    Tan, Ying
    RSC ADVANCES, 2019, 9 (59) : 34293 - 34298
  • [34] A rapid and facile immunoassay for C-reactive protein using PDMS-based digital magnetofluidics
    Ngernpradab, Pakakan
    Wongravee, Kanet
    Srisa-Art, Monpichar
    ANALYTICA CHIMICA ACTA, 2024, 1321
  • [35] Nets of biotin-derived gold nanoparticles as a label for the C-reactive protein immunoassay
    Kokorina, Alina A.
    Rashchevskaya, Regina O.
    Goryacheva, Irina Yu
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (27) : 6867 - 6875
  • [36] Nets of biotin-derived gold nanoparticles as a label for the C-reactive protein immunoassay
    Alina A. Kokorina
    Regina O. Rashchevskaya
    Irina Yu. Goryacheva
    Analytical and Bioanalytical Chemistry, 2021, 413 : 6867 - 6875
  • [37] Detection of C-Reactive Protein Using Histag-HRP Functionalized Nanoconjugate with Signal Amplified Immunoassay
    Siddiqui, Mohd Farhan
    Khan, Zeeshan Ahmad
    Park, Seungkyung
    NANOMATERIALS, 2020, 10 (06)
  • [38] On-Chip Determination of C-Reactive Protein Using Magnetic Particles in Continuous Flow
    Phurimsak, Chayakom
    Tarn, Mark D.
    Peyman, Sally A.
    Greenman, John
    Pamme, Nicole
    ANALYTICAL CHEMISTRY, 2014, 86 (21) : 10552 - 10559
  • [39] DEVELOPMENT OF QUANTITATIVE AUTOMATED IMMUNOASSAY FOR C-REACTIVE PROTEIN
    TUHY, PM
    SCHWARTZ, MW
    GORMAN, EG
    SCHIFREEN, RS
    WARKENTIN, DL
    BIENVENU, J
    CLINICAL CHEMISTRY, 1987, 33 (06) : 960 - 960
  • [40] A colorimetric homogeneous immunoassay system for the C-reactive protein
    Byun, Ju-Young
    Shin, Yong-Beom
    Kim, Dong-Myung
    Kim, Min-Gon
    ANALYST, 2013, 138 (05) : 1538 - 1543