Detection of c-reactive protein based on a magnetic immunoassay by using functional magnetic and fluorescent nanoparticles in microplates

被引:27
|
作者
Yang, S. F. [1 ]
Gao, B. Z. [1 ]
Tsai, H. Y. [2 ,3 ]
Fuh, C. Bor [1 ]
机构
[1] Natl Chi Nan Univ, Dept Appl Chem, Puli 545, Nantou, Taiwan
[2] Chung Shan Med Univ, Dept Appl Chem, Taichung 402, Taiwan
[3] Chung Shan Med Univ Hosp, Clin Lab, Taichung 402, Taiwan
关键词
NANOCRYSTALS;
D O I
10.1039/c4an00921e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report the preparation and application of biofunctional nanoparticles to detect C-reactive protein (CRP) in magnetic microplates. A CRP model biomarker was used to test the proposed detection method. Biofunctional magnetic nanoparticles, CRP, and biofunctional fluorescent nanoparticles were used in a sandwich nanoparticle immunoassay. The CRP concentrations in the samples were deduced from the reference plot, using the fluorescence intensity of the sandwich nanoparticle immunoassay. When biofunctional nanoparticles were used to detect CRP, the detection limit was 1.0 ng ml(-1) and the linear range was between 1.18 ng ml(-1) and 11.8 mu g ml(-1). The results revealed that the method involving biofunctional nanoparticles exhibited a lower detection limit and a wider linear range than those of the enzyme-linked immunosorbent assay (ELISA) and most other methods. For CRP measurements of serum samples, the differences between this method and ELISA in CRP measurements of serum samples were less than 13%. The proposed method can reduce the analysis time to one-third that of ELISA. This method demonstrates the potential to replace ELISA for rapidly detecting biomarkers with a low detection limit and a wide dynamic range.
引用
收藏
页码:5576 / 5581
页数:6
相关论文
共 50 条
  • [41] DEVELOPMENT OF AN ENZYME-IMMUNOASSAY FOR C-REACTIVE PROTEIN
    BURGER, W
    SCHMECHTA, H
    TAMBOR, A
    PORSTMANN, T
    VONBAEHR, R
    ZEITSCHRIFT FUR KLINISCHE MEDIZIN-ZKM, 1986, 41 (05): : 385 - 387
  • [42] A simple aptamer-based colorimetric assay for rapid detection of C-reactive protein using gold nanoparticles
    Antonio, Maria
    Ferreira, Rita
    Vitorino, Rui
    Daniel-da-Silva, Ana L.
    TALANTA, 2020, 214
  • [43] Multiple antigens detection by SERS-based immunoassay using Au and magnetic nanoparticles
    Neng, Jing
    Harpster, Mark H.
    Johnson, Patrick A.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 242
  • [44] Simultaneous determination of ochratoxin A and enterotoxin A in milk by magnetic nanoparticles based fluorescent immunoassay
    Becheva, Zlatina R.
    Ivanov, Yavor L.
    Godjevargova, Tzonka I.
    Tchorbanov, Andrey I.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2021, 38 (07): : 1218 - 1236
  • [45] One-step immunoassay of C-reactive protein using droplet microfluidics
    Tang, Matthew Y. H.
    Shum, Ho Cheung
    LAB ON A CHIP, 2016, 16 (22) : 4359 - 4365
  • [46] Conventional diagnosis of C-reactive protein in serum using latex piezoelectric immunoassay
    Aizawa, H
    Kurosawa, S
    Ogawa, K
    Yoshimoto, M
    Miyake, J
    Tanaka, H
    SENSORS AND ACTUATORS B-CHEMICAL, 2001, 76 (1-3) : 173 - 176
  • [47] Fluorescent detection of protein kinase based on zirconium ions-immobilized magnetic nanoparticles
    Tan, Penglong
    Lei, Chunyang
    Liu, Xin
    Qing, Meng
    Nie, Zhou
    Guo, Manli
    Huang, Yan
    Yao, Shouzhuo
    ANALYTICA CHIMICA ACTA, 2013, 780 : 89 - 94
  • [48] Simultaneous determination of ochratoxin A and enterotoxin A in milk by magnetic nanoparticles based fluorescent immunoassay
    Becheva, Zlatina R.
    Ivanov, Yavor L.
    Godjevargova, Tzonka I.
    Tchorbanov, Andrey I.
    Food Additives and Contaminants - Part A Chemistry, Analysis, Control, Exposure and Risk Assessment, 2021, 38 (07): : 1218 - 1236
  • [49] IMMUNOASSAY OF C-REACTIVE PROTEIN USING THE HITACHI-705E ANALYZER
    HARMOINEN, A
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1985, 23 (01): : 45 - 46
  • [50] Wash-free detection of C-reactive protein based on third-harmonic signal measurement of magnetic markers
    Enpuku, Keiji
    Shibakura, Misako
    Arao, Yujiro
    Mizoguchi, Takako
    Kandori, Akihiko
    Hara, Misato
    Tsukada, Keiji
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2018, 57 (09)