On-Chip Determination of C-Reactive Protein Using Magnetic Particles in Continuous Flow

被引:34
|
作者
Phurimsak, Chayakom [1 ]
Tarn, Mark D. [1 ]
Peyman, Sally A. [1 ]
Greenman, John [2 ]
Pamme, Nicole [1 ]
机构
[1] Univ Hull, Dept Chem, Kingston Upon Hull HU6 7RX, N Humberside, England
[2] Univ Hull, Sch Biol Biomed & Environm Sci, Kingston Upon Hull HU6 7RX, N Humberside, England
基金
英国工程与自然科学研究理事会;
关键词
MICROFLUIDIC SYSTEM; CARDIOVASCULAR RISK; IMMUNOASSAY; MICROCHIP; SERUM; ASSAYS; CRP; NANOPARTICLES; BIOMARKERS; DISEASE;
D O I
10.1021/ac5023265
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We demonstrate the application of a multilaminar flow platform, in which functionalized magnetic particles are deflected through alternating laminar flow streams of reagents and washing solutions via an external magnet, for the rapid detection of the inflammatory biomarker, C-reactive protein (CRP). The two-step sandwich immunoassay was accomplished in less than 60 s, a vast improvement on the 80-300 min time frame required for enzyme-linked immunosorbent assays (ELISA) and the 50 min necessary for off-chip magnetic particle-based assays. The combination of continuous flow and a stationary magnet enables a degree of autonomy in the system, while a detection limit of 0.87 mu g mL(-1) makes it suitable for the determination of CRP concentrations in clinical diagnostics. Its applicability was further proven by assaying real human serum samples and comparing those results to values obtained using standard ELISA tests.
引用
收藏
页码:10552 / 10559
页数:8
相关论文
共 50 条
  • [1] Rapid, multistep on-chip DNA hybridisation in continuous flow on magnetic particles
    Vojtisek, Martin
    Iles, Alexander
    Pamme, Nicole
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (09): : 2172 - 2176
  • [2] On-chip free-flow magnetophoresis: Continuous flow separation of magnetic particles and agglomerates
    Pamme, N
    Manz, A
    ANALYTICAL CHEMISTRY, 2004, 76 (24) : 7250 - 7256
  • [3] On-chip free-flow magnetophoresis - Separation and detection of mixtures of magnetic particles in continuous flow
    Pamme, N
    Manz, A
    MICRO TOTAL ANALYSIS SYSTEMS 2004, VOL 1, 2005, (296): : 49 - 51
  • [4] On-chip free-flow magnetophoresis: Separation and detection of mixtures of magnetic particles in continuous flow
    Pamme, Nicole
    Eijkel, Jan C. T.
    Manz, Andreas
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2006, 307 (02) : 237 - 244
  • [5] NEPHELOMETRIC DETERMINATION OF C-REACTIVE PROTEIN
    GAGE, S
    SEYMOUR, D
    VALENTA, R
    CERNOSEK, S
    CLINICAL CHEMISTRY, 1989, 35 (06) : 1197 - 1197
  • [6] DETERMINATION OF C-REACTIVE PROTEIN USING THE RA-1000
    BLAU, N
    FANCONI, S
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1986, 24 (10): : 783 - 783
  • [7] On-chip control of magnetic particles
    Rinklin, Philipp
    Krause, Hans-Joachim
    Wolfrum, Bernhard
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2012, 209 (05): : 871 - 874
  • [8] On-chip bioanalysis with magnetic particles
    Pamme, Nicole
    CURRENT OPINION IN CHEMICAL BIOLOGY, 2012, 16 (3-4) : 436 - 443
  • [9] On-chip analysis of atmospheric ice-nucleating particles in continuous flow
    Tarn, Mark D.
    Sikora, Sebastien N. F.
    Porter, Grace C. E.
    Wyld, Bethany, V
    Alayof, Matan
    Reicher, Naama
    Harrison, Alexander D.
    Rudich, Yinon
    Shim, Jung-uk
    Murray, Benjamin J.
    LAB ON A CHIP, 2020, 20 (16) : 2889 - 2910
  • [10] DETERMINATION OF C-REACTIVE PROTEIN IN INFECTIVE HEPATITIS
    SHMERLING, L
    PASHININ, PM
    JOURNAL OF MICROBIOLOGY EPIDEMIOLOGY AND IMMUNOBIOLOGY USSR, 1961, 32 (03): : 455 - +