Accuracy of dental digitizers

被引:0
|
作者
Vlaar, Simon T.
van der Zel, Jef M.
机构
[1] Univ Amsterdam, Acad Ctr Dent Amsterdam, Dept Computerized Dent, NL-1066 EA Amsterdam, Netherlands
[2] Free Univ Amsterdam, NL-1066 EA Amsterdam, Netherlands
关键词
dental CAD/CAM; surface digitization device; laser-triangulation scanning; dental imaging; scanning accuracy;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The need for proper validation and verification methodology for CAD/CAM systems is imminent. CAD/CAM systems consisting of an optical impression system, design software and a fabrication machine have to perform to a certain level, whereby manufacturers need to prove the effectiveness of the system as a whole. However, especially when dental surface digitization devices are used as open, stand-alone applications in dental outsourcing, a reliable standard test for comparison is necessary. Purpose: This study evaluates a proposed test method to be used to quantify "digitizing quality" with respect to accuracy and reproducibility of two dental surface digitization devices. Comparability of the characteristics should be ensured. Method: Two laser light section scanners: DentaScope 11 and D200 were evaluated by means of the 'Sphere Test', that involves repeated measurements of a precision ball (radius: 6mm) according to a pre-defined protocol. The surface information was received as unmatched, overlapping point clouds and statistically processed with a newly developed software package. The standard deviation of all points as well as a measure for undercutting the equator were determined. Results: The standard deviation for the radius for D and S were 7.7 ( +/- 0.8) and 13.9 ( +/- 1.0) mu m respectively. The equator undercut elevations were -2.01 degrees and -0.25 degrees for scanner D and S respectively. Conclusion: Scanner D had a significantly higher accuracy than S (p<0.05), corresponding with the smaller pixel distance of the sensor. Both devices show adequate accuracy and reproducibility and have an adequate ability to detect the equator. The test is also suitable for calibration purposes.
引用
收藏
页码:301 / 309
页数:9
相关论文
共 50 条
  • [1] Accuracy of Optical Dental Digitizers: An In Vitro Study
    Vandeweghe, Stefan
    Vervack, Valentin
    Vanhove, Christian
    Dierens, Melissa
    Jimbo, Ryo
    De Bruyn, Hugo
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2015, 35 (01) : 115 - 121
  • [2] ACCURACY OVER WORKING LIFE IN ANGLE DIGITIZERS
    DOMRACHEV, VG
    ISAEV, VM
    MEIKO, BS
    MEASUREMENT TECHNIQUES USSR, 1988, 31 (06): : 524 - 527
  • [3] Accuracy over working life in angle digitizers
    Domrachev, V.G.
    Isaev, V.M.
    Meiko, B.S.
    Measurement Techniques, 1988, 31 (06) : 524 - 527
  • [4] ACCURACY OF ANGLE DIGITIZERS FOR POLYMODAL INSTRUMENTAL ERROR DISTRIBUTION-FUNCTIONS
    DOMRACHEV, VG
    MEIKO, GS
    SAPEGIN, AG
    MEASUREMENT TECHNIQUES, 1980, 23 (12) : 1065 - 1069
  • [5] ACCURACY-CHECKING METHOD FOR PRECISION ANGLE DIGITIZERS BASED ON MULTIFACED PRISMS
    DOMRACHEV, VG
    TOPILSKII, VB
    MEIKO, BS
    ISAEV, VM
    KARPENKO, IA
    MEASUREMENT TECHNIQUES USSR, 1986, 29 (05): : 374 - 377
  • [6] A BUBBLE CHAMBER FILM MEASURING SYSTEM EMPLOYING HIGH ACCURACY IMAGE PLANE DIGITIZERS
    HILL, DG
    PALMER, RB
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1969, 40 (07): : 878 - &
  • [7] MORE ON DIGITIZERS
    PETRIE, G
    AREA, 1980, 12 (02) : 161 - 163
  • [8] ACCURACY OF DENTAL SURVEYORS
    AHMAD, I
    WATERS, NE
    JOURNAL OF DENTISTRY, 1991, 19 (03) : 181 - 185
  • [9] ACCURACY-CHECKING METHOD FOR PRECISION ANGLE DIGITIZERS BASED ON MULTIFACED PRISMS.
    Domrachev, V.G.
    Topil'skii, V.B.
    Meiko, B.S.
    Isaev, V.M.
    Karpenko, I.A.
    Measurement Techniques, 1986, 29 (05) : 374 - 377
  • [10] Accuracy of dental hygienists in diagnosing dental decay
    Ohrn, K
    Crossner, CG
    Borgesson, I
    Taube, A
    COMMUNITY DENTISTRY AND ORAL EPIDEMIOLOGY, 1996, 24 (03) : 182 - 186