Improvement of the Measuring Accuracy of the Raman Lidar for Remote Detection of the Hydrogen Gas

被引:6
|
作者
Choi, In-Young [1 ]
Baik, Sung-Hoon [1 ]
Park, Nak-Gyu [1 ]
Kang, Hee-Young [2 ]
Kim, Jin-Ho [2 ]
机构
[1] Korea Atom Energy Res Inst, Div Quantum Opt, 70,Yuseong Daero 1312beon Gil, Daejeon 34057, South Korea
[2] Korea Nucl Technol Co LTD, Div R&D Ctr, 277,Baeul 1Ro, Daejeon 34036, South Korea
关键词
Hydrogen gas; Raman lidar; Remote detection; Background noise; SENSOR; RELIABILITY;
D O I
10.1007/s12541-018-0114-z
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Hydrogen gas detection technique is very important because it is very flammable and explosive. A Raman lidar system is one of the techniques for the detection of hydrogen gas remotely. The signal to noise ratio of the Raman lidar is not high, because Raman scattering signals by the hydrogen gas are very weak and its signals include the background noise signals such as the pumping laser, laser-induced fluorescents signals, and ambient light. This paper discusses the improvement of the accuracy of the Raman lidar system for measuring hydrogen gas by eliminating the background noise signals. To verify the accuracy improvement effects, experiments of measuring the hydrogen gas concentration are carried out. As the results of the experiment, The coefficient of the determination(R-2) of the calibrated Raman signal of the hydrogen gas distribution by using the background noise signals was improved from 0.9985 to 0.9995 and the mean of the measuring error rates are decreased from 0.9794 to 0.7179, which is an improvement of about 27%.
引用
收藏
页码:967 / 973
页数:7
相关论文
共 50 条
  • [1] Improvement of the Measuring Accuracy of the Raman Lidar for Remote Detection of the Hydrogen Gas
    In-Young Choi
    Sung-Hoon Baik
    Nak-Gyu Park
    Hee-Young Kang
    Jin-Ho Kim
    International Journal of Precision Engineering and Manufacturing, 2018, 19 : 967 - 973
  • [2] Raman lidar system for hydrogen gas detection
    Ninomiya, Hideki
    Yaeshima, Saeko
    Ichikawa, Kouji
    Fukuchi, Tetsuo
    OPTICAL ENGINEERING, 2007, 46 (09)
  • [3] Remote sensing of hydrogen gas concentration distribution by Raman lidar
    Asahi, Ippei
    Sugimoto, Sachiyo
    Ninomiya, Hideki
    Fukuchi, Tetsuo
    Shiina, Tatsuo
    LIDAR REMOTE SENSING FOR ENVIRONMENTAL MONITORING XIII, 2012, 8526
  • [4] Advancements in Remote Raman-Lidar for Hydrogen Leakage Detection
    Deng Jinrui
    Jiang Ruijing
    Hai, Zhong
    Zhang Haoxiang
    Cui Liuhua
    Lei, Cai
    LASER & OPTOELECTRONICS PROGRESS, 2023, 60 (22)
  • [5] Compact Raman lidar for hydrogen gas leak detection
    Miya, Hiroaki
    Shiina, Tatsuo
    Kato, Takaaki
    Noguchi, Kazuo
    Fukuchi, Testuo
    Asahi, Ippei
    Sugimoto, Sachiyo
    Ninomiya, Hideki
    Shimamoto, Yuzo
    2009 LASERS & ELECTRO-OPTICS & THE PACIFIC RIM CONFERENCE ON LASERS AND ELECTRO-OPTICS, VOLS 1 AND 2, 2009, : 40 - +
  • [6] Remotely measuring the hydrogen gas by using portable Raman lidar system
    Choi, In Young
    Baik, Sung Hoon
    Choi, Young Soo
    OPTICA APPLICATA, 2021, 51 (01) : 37 - 49
  • [7] Development of On-axis Raman Lidar System for Remotely Measuring Hydrogen Gas at Long Distance
    Choi, In Young
    Baik, Sung Hoon
    Lim, Jae Young
    Cha, Jung Ho
    Kim, Jin Ho
    KOREAN JOURNAL OF OPTICS AND PHOTONICS, 2018, 29 (03) : 119 - 125
  • [8] Raman Lidar System for the Hydrogen Molecules Remote Sensing in Atmosphere
    Privalov V.E.
    Shemanin V.G.
    Optics and Spectroscopy, 2023, 131 (06): : 441 - 445
  • [9] Study of a Method for Measuring Hydrogen Gas Concentration Using a Photon-counting Raman Lidar System
    Choi, In Young
    Baik, Sung Hoon
    Cha, Jung Ho
    Kim, Jin Ho
    KOREAN JOURNAL OF OPTICS AND PHOTONICS, 2019, 30 (03) : 114 - 119
  • [10] Remote detection and identification of plastics with hyperspectral Raman imaging lidar
    Somekawa, Toshihiro
    Kurahashi, Shinri
    Matsuda, Shohei
    Yogo, Akifumi
    Kuze, Hiroaki
    OPTICS LETTERS, 2025, 50 (01) : 57 - 60