Improvement of the Measuring Accuracy of the Raman Lidar for Remote Detection of the Hydrogen Gas

被引:6
|
作者
Choi, In-Young [1 ]
Baik, Sung-Hoon [1 ]
Park, Nak-Gyu [1 ]
Kang, Hee-Young [2 ]
Kim, Jin-Ho [2 ]
机构
[1] Korea Atom Energy Res Inst, Div Quantum Opt, 70,Yuseong Daero 1312beon Gil, Daejeon 34057, South Korea
[2] Korea Nucl Technol Co LTD, Div R&D Ctr, 277,Baeul 1Ro, Daejeon 34036, South Korea
关键词
Hydrogen gas; Raman lidar; Remote detection; Background noise; SENSOR; RELIABILITY;
D O I
10.1007/s12541-018-0114-z
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Hydrogen gas detection technique is very important because it is very flammable and explosive. A Raman lidar system is one of the techniques for the detection of hydrogen gas remotely. The signal to noise ratio of the Raman lidar is not high, because Raman scattering signals by the hydrogen gas are very weak and its signals include the background noise signals such as the pumping laser, laser-induced fluorescents signals, and ambient light. This paper discusses the improvement of the accuracy of the Raman lidar system for measuring hydrogen gas by eliminating the background noise signals. To verify the accuracy improvement effects, experiments of measuring the hydrogen gas concentration are carried out. As the results of the experiment, The coefficient of the determination(R-2) of the calibrated Raman signal of the hydrogen gas distribution by using the background noise signals was improved from 0.9985 to 0.9995 and the mean of the measuring error rates are decreased from 0.9794 to 0.7179, which is an improvement of about 27%.
引用
收藏
页码:967 / 973
页数:7
相关论文
共 50 条
  • [21] HYDROGEN GAS CONCENTRATION MEASUREMENT IN SMALL AREA USING RAMAN LIDAR MEASUREMENT TECHNNOLOGY
    Sugimoto, Sachiyo
    Asahi, Ippei
    Shiina, Tatuso
    28TH INTERNATIONAL LASER RADAR CONFERENCE (ILRC 28), 2018, 176
  • [22] Research on long-range hydrogen gas measurement for development of Raman lidar sensors
    Jeon, Kil Song
    Sim, Jaeung
    Cho, Won Bo
    Park, Byoungjik
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 67 : 119 - 126
  • [23] Remote Detection and Identification of CO2 Dissolved in Water Using a Raman Lidar System
    Somekawa, Toshihiro
    Tani, Atsushi
    Fujita, Masayuki
    APPLIED PHYSICS EXPRESS, 2011, 4 (11)
  • [24] Ship wake detection by Raman lidar
    Bunkin, Alexey F.
    Klinkov, Vladimir K.
    Lukyanchenko, Vladislav A.
    Pershin, Sergey M.
    APPLIED OPTICS, 2011, 50 (04) : A86 - A89
  • [25] Raman LIDAR detection of cloud base
    Demoz, B
    Starr, D
    Whiteman, D
    Evans, K
    Hlavka, D
    Peravali, R
    GEOPHYSICAL RESEARCH LETTERS, 2000, 27 (13) : 1899 - 1902
  • [26] RAMAN LIDAR FOR THE REMOTE MEASUREMENT OF SUBSURFACE OCEAN PARAMETERS
    LEONARD, DA
    CAPUTO, B
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1984, 489 : 277 - 280
  • [27] Probing hydrogen molecules with a laboratory raman lidar
    Voronina, EI
    Privalov, VE
    Shemanin, VG
    TECHNICAL PHYSICS LETTERS, 2004, 30 (03) : 178 - 179
  • [28] Remote Sensing of Arctic Ocean by Compact Raman LIDAR
    Bunkin, A. F.
    Klinkov, V. K.
    Lednev, V. N.
    Marchenko, A. V.
    Pershin, S. M.
    Yulmetov, R. N.
    ICE RESEARCH FOR A SUSTAINABLE ENVIRONMENT, VOLS I & II, 2012, : 674 - 684
  • [29] Probing hydrogen molecules with a laboratory Raman lidar
    E. I. Voronina
    V. E. Privalov
    V. G. Shemanin
    Technical Physics Letters, 2004, 30 : 178 - 179
  • [30] Improvement of measuring accuracy of an optical CMM
    Chao, Z. X.
    Ong, S. S.
    Tan, S. L.
    INTERNATIONAL CONFERENCE ON OPTICS IN PRECISION ENGINEERING AND NANOTECHNOLOGY (ICOPEN 2011), 2011, 19