Improvement of the Measuring Accuracy of the Raman Lidar for Remote Detection of the Hydrogen Gas

被引:6
|
作者
Choi, In-Young [1 ]
Baik, Sung-Hoon [1 ]
Park, Nak-Gyu [1 ]
Kang, Hee-Young [2 ]
Kim, Jin-Ho [2 ]
机构
[1] Korea Atom Energy Res Inst, Div Quantum Opt, 70,Yuseong Daero 1312beon Gil, Daejeon 34057, South Korea
[2] Korea Nucl Technol Co LTD, Div R&D Ctr, 277,Baeul 1Ro, Daejeon 34036, South Korea
关键词
Hydrogen gas; Raman lidar; Remote detection; Background noise; SENSOR; RELIABILITY;
D O I
10.1007/s12541-018-0114-z
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Hydrogen gas detection technique is very important because it is very flammable and explosive. A Raman lidar system is one of the techniques for the detection of hydrogen gas remotely. The signal to noise ratio of the Raman lidar is not high, because Raman scattering signals by the hydrogen gas are very weak and its signals include the background noise signals such as the pumping laser, laser-induced fluorescents signals, and ambient light. This paper discusses the improvement of the accuracy of the Raman lidar system for measuring hydrogen gas by eliminating the background noise signals. To verify the accuracy improvement effects, experiments of measuring the hydrogen gas concentration are carried out. As the results of the experiment, The coefficient of the determination(R-2) of the calibrated Raman signal of the hydrogen gas distribution by using the background noise signals was improved from 0.9985 to 0.9995 and the mean of the measuring error rates are decreased from 0.9794 to 0.7179, which is an improvement of about 27%.
引用
收藏
页码:967 / 973
页数:7
相关论文
共 50 条
  • [41] Research on measuring accuracy improvement for tool Presetter
    1600, Trans Tech Publications Ltd (572):
  • [42] Improvement in the accuracy of measuring diameter by the coordinate method
    A. B. Matantsev
    Measurement Techniques, 2007, 50 : 841 - 845
  • [43] POSSIBILITIES FOR THE IMPROVEMENT OF ACCURACY OF OPTOELECTRONIC MEASURING SYSTEMS
    HEBERLING, J
    HEIDER, M
    TECHNISCHES MESSEN, 1992, 59 (11): : 454 - 458
  • [44] Improvement in the accuracy of measuring diameter by the coordinate method
    Matantsev, A. B.
    MEASUREMENT TECHNIQUES, 2007, 50 (08) : 841 - 845
  • [45] Development of remote sensing technology for hydrogen gas concentration measurement using raman scattering effect
    Ninomiya, Hideki
    Asahi, Ippei
    Sugimoto, Sachiyo
    Shimamoto, Yuzou
    IEEJ Transactions on Electronics, Information and Systems, 2009, 129 (07) : 1181 - 1185
  • [46] RAMAN LIDAR SYSTEM FOR METHANE GAS CONCENTRATION MEASUREMENTS
    HOUSTON, JD
    SIZGORIC, S
    ULITSKY, A
    BANIC, J
    APPLIED OPTICS, 1986, 25 (13): : 2115 - 2121
  • [47] Leak detection of hydrogen gas using anti-stokes raman scattering
    Electric Power Engineering Research Laboratory, Central Research Institute of Electric Power Industry, 2-6-1 Nagasaka, Yokosuka-shi, Kanagawa 240-0196, Japan
    不详
    IEEJ Trans. Electron. Inf. Syst., 2008, 7 (25+1191-1196):
  • [48] Influence analysis of the detection accuracy of atmospheric water vapor using the solar-blind ultraviolet Raman lidar
    Shi, Dongchen
    Hua, Dengxin
    Gao, Fei
    Chen, Ting
    Stanic, Samo
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2020, 251
  • [49] Accuracy of remote sensing of water temperature by Raman spectroscopy
    Becucci, M
    Cavalieri, S
    Eramo, R
    Fini, L
    Materazzi, M
    APPLIED OPTICS, 1999, 38 (06) : 928 - 931
  • [50] Analytical accuracy of hydrogen measurement using gas chromatography with thermal conductivity detection
    Yao Weijun