Study of a Method for Measuring Hydrogen Gas Concentration Using a Photon-counting Raman Lidar System

被引:1
|
作者
Choi, In Young [1 ]
Baik, Sung Hoon [1 ]
Cha, Jung Ho [2 ]
Kim, Jin Ho [2 ]
机构
[1] Korea Atom Energy Res Inst, Div Quantum Opt, 111 Daedeok Daero 989Beon Gil, Daejeon 34057, South Korea
[2] Korea Nucl Technol Co Ltd, Div R&D Ctr, 277,Baeul 1 Ro, Daejeon 34036, South Korea
关键词
Raman lidar system; Hydrogen gas; Remote detection; Measurement algorithm; Raman scattering signal;
D O I
10.3807/KJOP.2019.30.3.114
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This paper discusses the development of a Raman lidar system for remote detection and measurement of hydrogen gas by using a photon counter. The Raman signal of the hydrogen gas is very weak and has a very low signal-to-noise ratio. The photon counter has the advantage of improving the signal-to-noise ratio, because it has a discriminator to eliminate the background noise from the Raman signal of the hydrogen gas. Therefore, a small and portable Raman lidar system was developed using a low-power pulsed laser and a photon-counter system to measure the hydrogen gas concentration remotely. To verify the capability of measuring hydrogen gas using the developed photon-counting Raman lidar system, experiments were carried out using a gas chamber in which it is possible to adjust the hydrogen gas concentration. As a result, our photon-counting Raman lidar system is seen to measure a minimum concentration of 0.65 vol.% hydrogen gas at a distance of 10 m.
引用
收藏
页码:114 / 119
页数:6
相关论文
共 50 条
  • [1] Development of a Raman Lidar System Using the Photon-counting Method to Measure Carbon Dioxide
    Park, Sun Ho
    Choi, In Young
    Yoon, Moon Sang
    KOREAN JOURNAL OF OPTICS AND PHOTONICS, 2024, 35 (02) : 71 - 80
  • [2] A hydrogen gas concentration measurement method using the Raman lidar system
    Choi, In Young
    Baik, Sung Hoon
    Cha, Jung Ho
    Kim, Jin Ho
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2019, 30 (05)
  • [3] Remotely measuring the hydrogen gas by using portable Raman lidar system
    Choi, In Young
    Baik, Sung Hoon
    Choi, Young Soo
    OPTICA APPLICATA, 2021, 51 (01) : 37 - 49
  • [4] Photon-counting chirped amplitude modulation lidar using a smart premixing method
    Zhang, Zijing
    Zhang, Jianlong
    Wu, Long
    Zhang, Yong
    Zhao, Yuan
    Su, Jianzhong
    OPTICS LETTERS, 2013, 38 (21) : 4389 - 4392
  • [5] MEASURING SUBNANOSECOND FLUORESCENT LIFETIMES USING PHOTON-COUNTING
    WONG, DK
    HALPERN, AM
    PHOTOCHEMISTRY AND PHOTOBIOLOGY, 1976, 24 (06) : 609 - 611
  • [6] A HIGHLY-SENSITIVE MEASUREMENT SYSTEM FOR RAMAN-SPECTRA BY A PHOTON-COUNTING METHOD
    FUTAMATA, M
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1991, 2 (12) : 1207 - 1209
  • [7] Moving target ranging method for a photon-counting system
    Xue, Wei
    Liu, Li
    Dai, Xiangyang
    Luo, Yan
    OPTICS EXPRESS, 2018, 26 (26): : 34161 - 34178
  • [8] A Quantification Method for Breast Tissue Thickness and Iodine Concentration Using Photon-Counting Detector
    Han, Seokmin
    JOURNAL OF DIGITAL IMAGING, 2015, 28 (05) : 594 - 603
  • [9] A Quantification Method for Breast Tissue Thickness and Iodine Concentration Using Photon-Counting Detector
    Seokmin Han
    Journal of Digital Imaging, 2015, 28 : 594 - 603
  • [10] A photon-counting LiDAR bathymetric method based on adaptive variable ellipse filtering
    Chen, Yifu
    Le, Yuan
    Zhang, Dongfang
    Wang, Yong
    Qiu, Zhenge
    Wang, Lizhe
    REMOTE SENSING OF ENVIRONMENT, 2021, 256