Induction and binding of Cd, Cu, and Zn to metallothionein in carp (Cyprinus carpio) using HPLC-ICP-TOFMS

被引:46
|
作者
Van Campenhout, K
Infante, HG
Adams, F
Blust, R
机构
[1] Univ Antwerp, Dept Biol, Ecophysiol Biochem & Toxicol Grp, B-2020 Antwerp, Belgium
[2] Univ Instelling Antwerp, Dept Chem, B-2610 Antwerp, Belgium
关键词
Cyprinus carpio; metallothionein; copper; zinc; cadmium; HPLC ICP-TOFMS;
D O I
10.1093/toxsci/kfh149
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
The binding of Cd, Cu, and Zn to metallothionein in carp was studied under control and acute Cd exposure scenarios. Carp were exposed to different Cd concentrations for 96 h. Total (Cu, Cd, Zn)-MT levels were determined by the cadmium thiomolybdate saturation assay. Total tissue and cytosolic Cd, Cu, and Zn concentrations were determined by ICP-MS. The cytosolic metal speciation was determined by high pressure liquid chromatography (size-exclusion [SE] in combination with anion exchange [AE]) directly coupled to an inductively coupled plasma time of flight mass spectrometer (ICP-TOFMS). This coupled technique allows the chromatographic separation and online determination of the metals associated to the protein fractions separated. Very strong differences in the tissue compartmentalization and cytosolic speciation of the metals were observed. For example, over 30% of cytosolic zinc was bound to MT in liver while this was only 2% in the kidneys although total cytosolic levels were considerably higher. Induction of metallothionein during cadmium exposure was also tissue specific, displaying different response patterns in gills, liver, and kidney. Cadmium accumulated much stronger in liver and kidney compared to the gills and the latter also showed much lower MT levels. The renal MT-induction was more sensitive to Cd exposure than the hepatic MT induction since a significant increase of Cd-MT and total MT levels occurred at lower tissue Cd concentrations in the kidney in comparison to the liver, except for the highest Cd exposure level where a drastic 10-fold increase in hepatic Cd-MT was observed. At this Cd exposure level also an apparent spill over of zinc to the high molecular weight fraction was observed in the kidneys.
引用
收藏
页码:276 / 287
页数:12
相关论文
共 48 条
  • [31] Investigation of simultaneous adsorption properties of Cd, Cu, Pb and Zn by pristine rice husks using ICP-AES and LA-ICP-MS analysis
    Alexander, David
    Ellerby, Ryan
    Hernandez, Avery
    Wu, Fengchang
    Amarasiriwardena, Dulasiri
    MICROCHEMICAL JOURNAL, 2017, 135 : 129 - 139
  • [32] Determination of Cu, Ni, Zn, Mn, Co, Pb, Cd, and V in seawater using flow injection ICP-MS
    Willie, SN
    Iida, Y
    McLaren, JW
    ATOMIC SPECTROSCOPY, 1998, 19 (03) : 67 - 72
  • [33] Fast method for determination of Cd, Cu, Pb, Se, and Zn in whole blood by DRC-ICP-MS using the simple dilution procedure
    Tanaselia, C.
    Frentiu, T.
    Ursu, M.
    Vlad, M.
    Chintoanu, M.
    Cordos, Emil Alexandru
    David, L.
    Paul, M.
    Gomoiescu, D.
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2008, 2 (02): : 99 - 107
  • [34] Determination of Mn, Fe, Ni, Cu, Zn, Cd and Pb in seawater using offline extraction and triple quadrupole ICP-MS/MS
    Jackson, S. L.
    Spence, J.
    Janssen, D. J.
    Ross, A. R. S.
    Cullen, J. T.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (02) : 304 - 313
  • [35] A comparison of Fe, Zn, Cu, Cr, Cd and Pb concentration in serum determined by ICP-AES using different sample preparation procedures
    Zhang, XL
    Cao, H
    Yang, LX
    Wang, LX
    Duan, YY
    Zhang, SK
    Yang, XK
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 1999, 19 (03) : 364 - 366
  • [37] Influence of Surfactant and Ionic Liquid Media on Vapor Generation and Determination of Ag, Au, Cd, Cu, Ni, Sn, and Zn Using ICP-OES
    Villanueva-Alonso, Julia
    Suarez-Garcia, Ana
    Pena-Vazquez, Elena
    Bermejo-Barrera, Pilar
    ATOMIC SPECTROSCOPY, 2015, 36 (02) : 63 - 73
  • [38] A field survey of metal binding to metallothionein and other cytosolic ligands in liver of eels using an on-line isotope dilution method in combination with size exclusion (SE) high pressure liquid chromatography (HPLC) coupled to Inductively Coupled Plasma time-of-flight Mass Spectrometry (ICP-TOFMS)
    Van Campenhout, Karen
    Infante, Heidi Goenaga
    Goemans, Geert
    Belpaire, Claude
    Adams, Freddy
    Blust, Ronny
    Bervoets, Lieven
    SCIENCE OF THE TOTAL ENVIRONMENT, 2008, 394 (2-3) : 379 - 389
  • [39] INDUCTION-COUPLED PLASMA DETERMINATION OF AG, AU, BI, CD, CU, PB, AND ZN IN GEOLOGIC MATERIALS USING A SELECTIVE EXTRACTION TECHNIQUE - PRELIMINARY INVESTIGATION
    MOTOOKA, JM
    MOSIER, EL
    SUTLEY, SJ
    VIETS, JG
    APPLIED SPECTROSCOPY, 1979, 33 (05) : 456 - 460
  • [40] Determination of Mn, Fe, Co, Ni, Cu, Zn, Cd and Pb in seawater using high resolution magnetic sector inductively coupled mass spectrometry (HR-ICP-MS)
    Milne, Angela
    Landing, William
    Bizimis, Michael
    Morton, Peter
    ANALYTICA CHIMICA ACTA, 2010, 665 (02) : 200 - 207