Fast method for determination of Cd, Cu, Pb, Se, and Zn in whole blood by DRC-ICP-MS using the simple dilution procedure

被引:0
|
作者
Tanaselia, C. [1 ]
Frentiu, T. [2 ]
Ursu, M. [1 ]
Vlad, M. [3 ]
Chintoanu, M. [1 ]
Cordos, Emil Alexandru [1 ]
David, L. [4 ]
Paul, M. [1 ]
Gomoiescu, D. [1 ]
机构
[1] Res Inst Analyt Instrumentat, INCDO INOE 2000, Cluj Napoca, Romania
[2] Univ Babes Bolyai, Fac Chem & Chem Engn, R-3400 Cluj Napoca, Romania
[3] Luliu Moldovan Inst Publ Hlth, Cluj Napoca, Romania
[4] Univ Babes Bolyai, Fac Phys, R-3400 Cluj Napoca, Romania
关键词
mass spectrometry; dynamic reaction cell; toxic and essential elements; whole blood; certified materials;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A fast and very sensitive method based on inductively coupled plasma mass spectrometry and Dynamic Reaction Cell (DRC-ICP-MS) for determination of Cd, Cu, Pb, Se, and Zn in whole blood was developed by using of the reference certified materials. After a simple dilution of the samples (1 : 9) in a diluent containing 5 g l(-1) NH3, 0.5 g l(-1) Triton-X, 0.5 g l(-1) EDTA and 6 ml l(-1) butan-1-ol, they were directly introduced by pneumatic nebulization into the plasma. Excellent performances were achieved in reducing the polyatomic interferences on Cd, Se, and Pb isotopes through charge-transfer mechanism by the use of both butan-1-ol in the sample and DRC technology operated with methane as reaction gas. In the same circumstances, the results were only reasonably good for Zn and Cu. Limits of detection in undiluted whole blood sample were in the range of 1.5 ng l(-1) (for Cd and Pb) to 150 ng l(-1) (for Zn). The recovery degrees compared to the certified contents for a 95 % confidence level were: 105 +/- 5 % (Cd); 102 +/- 5 % (Se); 97 +/- 6 % (Pb); 100 +/- 11 % (Zn) and 106 +/- 23 % (Cu).
引用
收藏
页码:99 / 107
页数:9
相关论文
共 50 条
  • [1] Determination of chromium in whole blood by DRC-ICP-MS:: spectral and non-spectral interferences
    Bonnefoy, C
    Menudier, A
    Moesch, C
    Lachâtre, G
    Mermet, JM
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (02) : 167 - 173
  • [3] Determination of Cd, Pb and Se in beef samples using aerosol dilution by ICP-MS
    Fiorella Iaquinta
    Lucimar Lopes Fialho
    Joaquim A. Nóbrega
    Mariela Pistón
    Ignacio Machado
    Journal of Food Measurement and Characterization, 2021, 15 : 4105 - 4111
  • [4] Determination of Cd, Pb and Se in beef samples using aerosol dilution by ICP-MS
    Iaquinta, Fiorella
    Lopes Fialho, Lucimar
    Nobrega, Joaquim A.
    Piston, Mariela
    Machado, Ignacio
    JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION, 2021, 15 (05) : 4105 - 4111
  • [5] Analysis of whole human blood for Pb, Cd, Hg, Se, and Mn by ICP-DRC-MS for biomonitoring and acute exposures
    Jones, Deanna R.
    Jarrett, Jeffery M.
    Tevis, Denise S.
    Franklin, Melanie
    Mullinix, Neva J.
    Wallon, Kristen L.
    Quarles, C. Derrick, Jr.
    Caldwell, Kathleen L.
    Jones, Robert L.
    TALANTA, 2017, 162 : 114 - 122
  • [7] Direct determination of Cu and Zn in whole human blood by ICP-MS
    Mestek, O
    Curdova, E
    Koplik, R
    Zima, T
    CHEMICKE LISTY, 1997, 91 (12): : 1059 - 1062
  • [8] Simultaneous Determination of Cd, Pb, Cu, Zn, and Se in Human Blood of Jordanian Smokers by ICP-OES
    Adnan Massadeh
    Ahmed Gharibeh
    Khaled Omari
    Idrees Al-Momani
    Ahmed Alomari
    Hiatham Tumah
    Wail Hayajneh
    Biological Trace Element Research, 2010, 133 : 1 - 11
  • [9] Simultaneous Determination of Cd, Pb, Cu, Zn, and Se in Human Blood of Jordanian Smokers by ICP-OES
    Massadeh, Adnan
    Gharibeh, Ahmed
    Omari, Khaled
    Al-Momani, Idrees
    Alomari, Ahmed
    Tumah, Hiatham
    Hayajneh, Wail
    BIOLOGICAL TRACE ELEMENT RESEARCH, 2010, 133 (01) : 1 - 11
  • [10] Assessing the stability of Cd, Mn, Pb, Se, and total Hg in whole human blood by ICP-DRC-MS as a function of temperature and timen
    Tevis, Denise S.
    Jarrett, Jeffery M.
    Jones, Deanna R.
    Cheng, Po-Yung
    Franklin, Melanie
    Mullinex, Neva
    Caldwell, Kathleen L.
    Jones, Robert L.
    CLINICA CHIMICA ACTA, 2018, 485 : 1 - 6